What voltage are the BA set cable cutters insulated to?
1000v AC
1500v DC
What is the minimum period between each FMFT?
1 Month
When is BA Entry Control Procedure Introduced?
Whenever BA is worn
What is the maximum number of fire-fighters a Stage 2 BAEC Supervisor can be responsible for?
12
List the occasions personnel will perform a General Test on a BA Set?
Wholetime - when nominated to wear BA at the start of a shift
On-Call Training Night & Prior to wearing BA
When the set has been worn for Fire or Training
On return from BA Workshops
When collecting from a holding area at an incident
What is the purpose of the inner orinasal mask on the BA set?
Prevent the build-up of Carbon Dioxide in the mask when air is exhaled
List four safety features incorporated into the Interspiro DDU and BAC
Pressure Display
Manual DSU
Automatic DSU
Electronic Low Pressure Warning Whistle
Pneumatic Low Pressure Warning Whistle
Backlight
What is the maximum number of Stage 2 BAEC boards a single BA Sector Command Board can be responsible for?
4
What is the volume level of a sounding alarm on the Interspiro BA Set set (not test volume)
105Db
How long should the new batteries last on the BA Set torch when it is used continually?
6 hours
At what pressure would a cylinder fail the General Test on an Interspiro BA Set?
Below 270 Bar
At what pressure will the relief valve on the regulator operate (in bar)
12-20 bar
What is the correct composition of air on inhalation?
79% nitrogen
21 % oxygen
Define the term Tidal Capacity and state the volume?
Flow of air from the lungs under inactive conditions.
1/2 litre
What is the average lung capacity of a human adult in litres?
5.5 litres
List the four main parts of the respiratory tract
Trachea
Bronchi
Bronchioles
Alveoli
What is the length of the short personal line in metres?
1.25m
What is the overall length of a personal line in metres?
6m
When are stage 2 BA Entry Control Procedures Introduced?
When there are more than 6 wears.
Greater degree of command and control required from Incident Commander.
When guidelines are required.
When there are more than 1 entry points.
List three items of additional equipment provided with each Interspiro BA set?
BA Lamp
Cable Cutters
Retractable Personal Line
Identification Talley
1 Cylinder Cover
1 Compressed Air Cylinder
BA set Log Book
What is the approximate volume of air breathed by a person walking at 4 mph whilst wearing a BA Set (in L/Min)
50 lpm
How will you know when you have reached your TAL whilst wearing your Interspiro BA set at an incident?
Spiroguide DDU has TAP in display.
The DSU screen will turn red.
A double beep every 5 seconds.
List 8 rules to be remembered by BA wearer to enable proficient operation of BA Entry Control?
- BA is only to be worn on instruction from the Incident Commander.
- Ensure that they fully understand their brief, tasks instructions, where and how they are required to enter the risk area, any identified hazards and say any limitations on the duration of wear as determined by the person responsible for the BA entry control point.
- On instruction from the person responsible for the BA Entry Control Point, start up the BA Set, complete the pre-entry checks and proceed to the BA Entry control point.
- Carry out Comms, check prior to going under air, including Team Talk, and push to talk.
- Ensure an adequate face seal is established in safe air.
- Ensure that appropriate personal protective equipment is worn correctly.
- Approach BA Entry Control (in full PPE) holding DDU with key in. Turn Around Pressure (TAP) will be reset by BAECO before entering the risk area.
- Ensure their Talley is placed in the BA Entry Control Board with the ‘time-in’ section completed the BA Entry Control Operative before entering the risk area.
- Check firefighting equipment by operation before entering the risk area.
- Always carry out safe movement and search and rescue techniques, maintaining close personal contact between wearers
The pressure regulator is made of chromium plated marine grade brass.
It is capable of delivering more than ??? L/pm
450lts per min