BOOK 23 TRAINING BULLETINS Flashcards

(523 cards)

1
Q

TB073 TACTICAL AND OPERATIONAL CONSIDERATIONS
How should apparatus be parked?

A

manner which facilities RAPID WITHDRAWAL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

TB073 TACTICAL AND OPERATIONAL CONSIDERATIONS
When blocking a traffic lane, should traffic be allowed to proceed on both sides of the incident? how should you divert traffic to one side?

A

NO;
using traffic control devices

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

TB073 TACTICAL AND OPERATIONAL CONSIDERATIONS
What provides maximum visibility to oncoming traffic?

A

EMERGENCY LIGHTS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

TB073 TACTICAL AND OPERATIONAL CONSIDERATIONS
Before standing to side and knocking on door, you should listen for how many seconds then evaluate?

A

10 sec

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

TB073 TACTICAL AND OPERATIONAL CONSIDERATIONS
Where is the likeliest place to hide guns?

A

the bedroom

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

TB073 TACTICAL AND OPERATIONAL CONSIDERATIONS
What should you use to alert personnel to potential danger?

A

preplanned WORDS OF WARNING

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

TB073 TACTICAL AND OPERATIONAL CONSIDERATIONS
Can an assailant with nystagmus, paranoid or hyperactive be reasoned with?

A

NO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

TB073 TACTICAL AND OPERATIONAL CONSIDERATIONS
If a member is assaulted, who shall be notified and who shall be requested?

A

BC/Section Commander;
PD

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

TB073 TACTICAL AND OPERATIONAL CONSIDERATIONS
If a member feels that they are not injured, what should they do?

A

SEEK FIRST CARE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

TB073 TACTICAL AND OPERATIONAL CONSIDERATIONS
What is the Immediate Supervisors responsibility in terms of workplace violence?

A

SHALL DOCUMENT AND COMPLETE CIRCUMSTANCES OF WORKPLACE VIOLENCE ON WORKPLACE VIOLENCE INTAKE FORM AND POST INCIDENCE ASSESSMENT FORM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

TB076 COMPANY OPERATIONS
Which NFPA standard requires FF to operate in pairs of 2 or more?

A

NFPA 1500

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

TB076 COMPANY OPERATIONS
What is NFPA 1561?

A

Standard on Emergency Services Incident Management System

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

TB076 COMPANY OPERATIONS
Once command is established, subsequent companies are to stop where?

A

One block away from address

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

TB076 COMPANY OPERATIONS
SitStat and ReStat are maintained by?

A

F666 or dispatch printout AND APPARATUS ROSTER SYSTEM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

TB076 COMPANY OPERATIONS
What is the APPARATUS ROSTER SYSTEM and what NFPA requirement does it fulfill?

A

Provides accountability for members assigned to each company;
NFPA 1500

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

TB076 COMPANY OPERATIONS
What are 3 key deciding factors whether to assume exterior command or immediately commit to a tactical objective?

A

1) SAFETY OF CREW
2) WILL ATTACK EXTINGUISH OR CONFINE FIRE
3) DOES THE FIRE NEED IMMEDIATE COORDINATION DUE TO MAGNITUDE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

TB076 COMPANY OPERATIONS
Can IC be passed or transferred to another officer not on scene?

A

NO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

TB076 COMPANY OPERATIONS
Can an Engineer supplying water to multiple attack lines inside be considered a standby member? and why?

A

NO; abandoning his task could jeopardize the safety of other FF

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

TB076 COMPANY OPERATIONS
When shall IC designate one company to be RIC?

A

Upon arrival of additional resources beyond the initial structure fire assignment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

TB076 COMPANY OPERATIONS
When can RA’s initiate Firefighting operations when first on scene of a Structure Fire?

A

IMMINENT LIFE THREATENING SITUATION EXISTS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

TB076 COMPANY OPERATIONS
The Staff Aid monitors radio channels from which side of sedan?

A

LEFT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

TB076 COMPANY OPERATIONS
For larger incidents, what channel is used if there is no “STAGING CHANNEL?”

A

DIV TAC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

TB101 STANDARDIZED EMERGENCY MANAGEMENT SYSTEM
SEMS forms range from _____ to ______

A

ICS form 201 to ICS form 221

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

TB101 STANDARDIZED EMERGENCY MANAGEMENT SYSTEM
In order for local governments to be eligible for state funding of response related personnel costs, they must?

A

use STANDARDIZED EMERGENCY MANAGEMENT SYSTEM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
TB101 STANDARDIZED EMERGENCY MANAGEMENT SYSTEM Who is responsible for the overall incident?
IC
26
TB101 STANDARDIZED EMERGENCY MANAGEMENT SYSTEM Who is responsible for directing tactical actions to meet incident principles?
OPERATIONS
27
TB101 STANDARDIZED EMERGENCY MANAGEMENT SYSTEM Who is responsible for collection, evaluation, display of incident information, maintaining status of incident resources, and preparing IAP?
PLANNING/INTELLIGENCE
28
TB101 STANDARDIZED EMERGENCY MANAGEMENT SYSTEM What is the SPAN OF CONTROL?
Number of individuals one supervisor can effectively manage 3-7 5 is optimal
29
TB101 STANDARDIZED EMERGENCY MANAGEMENT SYSTEM Resources in Staging must always be in AVAILABLE status and must be ready for assignment in how many minutes?
3 minutes
30
TB101 STANDARDIZED EMERGENCY MANAGEMENT SYSTEM What is a resource KIND and TYPE?
Kind=what a resource is Type=performance capability for that kind of resource
31
TB101 STANDARDIZED EMERGENCY MANAGEMENT SYSTEM What is the highest resource type?
Type 1
32
TB101 STANDARDIZED EMERGENCY MANAGEMENT SYSTEM A S/T is a combination of?
resources of the SAME KIND AND TYPE
33
TB101 STANDARDIZED EMERGENCY MANAGEMENT SYSTEM What are the 3 status conditions?
1) assigned resources working on a tactical assignment under a supervisor 2) Available resource ready for deployment 3) Out of Service Resources not ready for available status
34
TB101 STANDARDIZED EMERGENCY MANAGEMENT SYSTEM What are 3 important command staff functions?
1) PUBLIC information and media relations 2) ensuring SAFETY 3) maintaining LIASON with assisting and cooperating agencies
35
TB101 STANDARDIZED EMERGENCY MANAGEMENT SYSTEM What is the ICS CHECK IN FORM?
FORM 211
36
TB101 STANDARDIZED EMERGENCY MANAGEMENT SYSTEM What is included in Unit Log ICS Form 214?
Names of assigned personnel Listing of major activities in an OPERATIONAL PERIOD
37
TB135 FD OPERATIONS AT TACTICAL LAW ENFORCEMENT What is THREAT?
T=THREAT SUPPRESSION H=HEMORRHAGE CONTROL RE=RAPID EXTRACTION TO SAFETY A=ASSESSMENT BY MEDICAL T=TRANSPORT TO DEFINITIVE CARE
38
TB135 FD OPERATIONS AT TACTICAL LAW ENFORCEMENT What is an ACTIVE SHOOTER response?
2BC 2EMS CI 1 COMMAND POST CO 1LF 2E 4ALS RA 2BLS RA
39
TB135 FD OPERATIONS AT TACTICAL LAW ENFORCEMENT When may MEDICAL BRANCH be established?
large number of patients distance makes it impractical to have one treatment area
40
TB135 FD OPERATIONS AT TACTICAL LAW ENFORCEMENT What areas are considered WARM?
Perimeter established by LE CCP(s)
41
TB135 FD OPERATIONS AT TACTICAL LAW ENFORCEMENT Limited equipment is required, what should be used?
M9 TEMS backpack
42
TB139 AIR MANAGEMENT POLICY how often shall members be trained on air management per NFPA1404?
annually
43
TB139 AIR MANAGEMENT POLICY What happens when low air alarm is activated?
last green LED turns red and begins to FLASH HUD, upper L, audible 33%
44
TB139 AIR MANAGEMENT POLICY When shall retraining occur? and what documentation shall be done?
annually in January PRB, F2, TARGET SOLUTIONS
45
TB003 TYPE IV BUILDINGS ALUMINUM What is the melting point of aluminum? approx how long does it take to reach the melting point?
1300F 10 min
46
TB008 ELECTRICAL HAZARDS What are the fire equivalent to: AMPS VOLTS OHMS CURRENT CONDUCTOR
AMPS=GPM VOLTS=PSI OHMS=FL CURRENT=WATER CONDUCTOR=HOSE
47
TB008 ELECTRICAL HAZARDS What is the range for high voltage?
600-59,999
48
TB008 ELECTRICAL HAZARDS What are the 2 components of a transmission system?
GRIDS TRANSMISSION LINES
49
TB008 ELECTRICAL HAZARDS What is the range of transmission lines? lines coming into LA?
69kV to 1000kV 230kV
50
TB008 ELECTRICAL HAZARDS How long can insulators be?
3-20'
51
TB008 ELECTRICAL HAZARDS How many times is voltage stepped down before it reaches customers?
3
52
TB008 ELECTRICAL HAZARDS How many receiving stations are in LA? and what is the voltage stepped down to?
21 stations 34.5kV
53
TB008 ELECTRICAL HAZARDS Distribution Stations receives voltage at ___ and steps it down to _____ (primary)
34.5kV 4.8kV
54
TB008 ELECTRICAL HAZARDS Overhead transformers step down voltage to?
120/240v
55
TB008 ELECTRICAL HAZARDS What are electrical lines placed directly in the ground called?
DB (designated direct buried)
56
TB008 ELECTRICAL HAZARDS What are insulators made of?
GLASS PORCELIN
57
TB008 ELECTRICAL HAZARDS What determines HIGH VOLTAGE?
1) "HIGH VOLTAGE" sign on crossers 2) size and shape of conductors 3) distance between conductors
58
TB008 ELECTRICAL HAZARDS The degree of shock depends on?
1) amount of current 2) length of time the current passes through the body
59
TB008 ELECTRICAL HAZARDS How much is the chance of survival reduced when defibrillation is delayed?
10% every minute
60
TB008 ELECTRICAL HAZARDS how many amps can cause heart paralysis?
4
61
TB008 ELECTRICAL HAZARDS When can one break the 10' away from power lines?
rescue attempt
62
TB008 ELECTRICAL HAZARDS Overhead communication wires can be charged up to?
50v
63
TB008 ELECTRICAL HAZARDS When spotting for a downed wire, how far do you spot the apparatus?
at least one span (pole to pole) OPTIMUM SAFETY min. 2 undamaged poles
64
TB008 ELECTRICAL HAZARDS conductors that feel street lights can be what voltage? and how should you approach it?
120-6150v DEFENSIVE POSTURE
65
TB008 ELECTRICAL HAZARDS What is the 30/33/100 rule?
30 deg fog 33' 100 psi min
66
TB008 ELECTRICAL HAZARDS When a Distribution/Substation fire occurs, when can you put water on electrical equipment?
DO NOT UNLESS DIRECTED BY LADWP
67
TB008 ELECTRICAL HAZARDS If a vehicle has been energized by wires and the occupant is able to drive the vehicle clear of the wires, how far should they drive?
Drive clear of wires by at least 35'
68
TB008 ELECTRICAL HAZARDS How far can a static charge jump?
2-3 inches
69
TB008 ELECTRICAL HAZARDS What is a safe distance from Transmission Towers?
35'
70
TB008 ELECTRICAL HAZARDS What is the minimum clearance from the outermost wire of electrical transmission lines?
100'
71
TB008 ELECTRICAL HAZARDS What is the explosive range of CARBON MONOXIDE?
12.5-74%
72
TB008 ELECTRICAL HAZARDS What is most likely burning in Vault/Manhole fires?
Conduit
73
TB008 ELECTRICAL HAZARDS With a Vault fire, how many manhole covers shall be located?
4 total; one in each direction
74
TB008 ELECTRICAL HAZARDS Manhole covers weight ___, can travel ____ in the air and at a distance of ___.
300lb 75' 125'
75
TB008 ELECTRICAL HAZARDS Who can cut HIGH VOLTAGE?
DWP LINE PATROLMAN on call 24hr can reach anywhere within 10 min
76
TB008 ELECTRICAL HAZARDS LADWP tests RUBBER GAUNTLET GLOVES every _____ at _____ ?
60 days 10,000v
77
TB008 ELECTRICAL HAZARDS What is an oil fuse cutout?
fuse between main line and transformer
78
TB008 ELECTRICAL HAZARDS The main fire hazard with electrical vaults is ____ which has a flash point of ____.
COOLING OIL 300 deg
79
TB035 OVERHAUL PROCEDURES What is the primary consideration for overhaul?
eliminating potential rekindle
80
TB035 OVERHAUL PROCEDURES What are the objectives of overhaul?
1) SAFETY of FD 2) ensure fire is OUT/ALL potential for rekindle is eliminated 3) LEAVE scene undisturbed 4) ID and PRESERVE all salvageable contents 5) PREMISES turned over to RP
81
TB035 OVERHAUL PROCEDURES What are the best forms of protection against dangerous forms of gases, vapors and particulates?
Time and Shielding
82
TB035 OVERHAUL PROCEDURES What should be used when an area is UNSAFE for personnel and SHALL BE COMPLETELY RESTRICTED?
Fireline Tape and Barricade Tape
83
TB035 OVERHAUL PROCEDURES What is ICS215A
INCIDENT ACTION PLAN SAFETY ANAYLSIS
84
TB035 OVERHAUL PROCEDURES What type of overhaul meets the traditional methods of the dept?
TRADITIONAL
85
TB035 OVERHAUL PROCEDURES When is WET OVERHAUL used?
NO SALVAGEABLE CONTENTS EXIST
86
TB035 OVERHAUL PROCEDURES Who coordinates a Fire watch?
MFC
87
TB035 OVERHAUL PROCEDURES What type of overhaul places piles in a location to minimize the inconvenience of the public?
COMPLETE OVERHAUL
88
TB035 OVERHAUL PROCEDURES How far should overhaul piles be placed?
min 10' from any part of the structure
89
TB035 OVERHAUL PROCEDURES What are 3 piles for overhaul?
SALVAGEABLE ITEMS NON SALVAGEABLE ITEMS COMBUSTABLE MATERIALS
90
TB035 OVERHAUL PROCEDURES What is the final phase of overhaul?
SECURING PREMISE BACK TO OWNER
91
TB090 FIRE BURNS What is a BTU?
amount of heat needed to raise ONE pound of water ONE DEGREE F
92
TB090 FIRE BURNS What is SPECIFIC HEAT?
the thermal capacity of a substance
93
TB090 FIRE BURNS solid to water is the latent heat of ____
FUSION; WATER =143 BTU
94
TB090 FIRE BURNS liquid to vapor is latent heat of _____
VAPORIZATION; 970 BTU
95
TB090 FIRE BURNS What are 3 ways heat is transferred?
1) RADIATION 2) CONVECTION 3) CONDUCTION
96
TB090 FIRE BURNS What are the 3 stages of fire?
1) GROWTH 2) FULLY DEVELOPED 3) DECAY
97
TB090 FIRE BURNS What marks the end of the GROWTH STAGE and beginning of the FULLY DEVELOPED STAGE?
FLASHOVER
98
TB090 FIRE BURNS What is the last warning sign for FF to withdrawal?
ROLLOVER
99
TB090 FIRE BURNS What are 5 warning signs of FLASHOVER?
1) Fire producing back up of smoke on upper floors 2) Smoke increasing in intensity and heat 3) Rapid banking down of heated smoke 4) Radiant/Convective heat 5) Rollover
100
TB090 FIRE BURNS What is the normal ceiling height?
8-10'
101
TB090 FIRE BURNS When does SMOKE EXPLOSION occur?
early stages, as super heated smoke particles accumulate and forced into enclosed hidden areas
102
TB090 FIRE BURNS What are warning signs of a SMOKE EXPLOSION?
1) sickly/intermittent flame due to low o2 level 2) smoke being drawn past you 3) heavy smoke swirling with great force 4) flickering flames in smoke above
103
TB090 FIRE BURNS What is the o2 content in a BACKDRAFT?
11-15%
104
TB106 LCES When communicating with the air horn, what is the notification for retreat?
10s of air horn 10s of silence x3 total of 50s
105
TB106 LCES LLCCESS
LOOKOUT LOCATION COMMUNICATIONS CONDITIONS ESCAPE ROUTE SAFETY ZONE SAFETY EQUIPMENT
106
TB106 LCES 14 SF WATCHOUTS
1) DELAY in entry 2) multiple co with minimal entry 3) ROOF is driven off with co inside 4) air drawn in rapidly, 0 visibility heat banking down 5) hear fire above but can't SEE it 6) under a MEZZANINE 7) feeling UNCOMFORTABLE 8) SCBA ALARM with no fire 9) FLOWING water for several min but no progress 10) ventilation BEHIND you 11) UNABLE TO COMMUNICATE WITH IC 12) working with UNFAMILIAR members 13) feeling FATIGUED 14) feel other person needs TRAINING
107
TB054 HAZARDOUS/ILLEGAL MEZZANINES What is an intermediate floor place in any story or room?
mezzanine or mezzanine floor
108
TB054 HAZARDOUS/ILLEGAL MEZZANINES When the total area of mezzanine exceeds 33 1/3% of the total floor area, it shall be considered?
an additional "story"
109
TB054 HAZARDOUS/ILLEGAL MEZZANINES The clear height above or below a mezzanine floor shall not be less than?
7'
110
TB054 HAZARDOUS/ILLEGAL MEZZANINES How many mezzanines can be in a room?
no limitation but there shall not be more than 2 levels of mezzanine in a room
111
TB054 HAZARDOUS/ILLEGAL MEZZANINES What is the max height of walls, railing, posts of a mezzanine?
42"
112
TB054 HAZARDOUS/ILLEGAL MEZZANINES When shall 2 exits be required on mezzanines?
occupant load over 10 or mezzanine exceeds 2,000 sq ft
113
TB054 HAZARDOUS/ILLEGAL MEZZANINES What shall occur when a sprinklered building does not have sprinklers under the mezzanine?
A notice shall be issued directing REMOVAL OF ALL COMBUSTABLE MATERIALS UNDER THE MEZZANINE and notification to FPB
114
TB054 HAZARDOUS/ILLEGAL MEZZANINES What if a mezzanine does not appear to support the weight of storage?
FIRE/LIFE SAFETY VIOLATION NOTICE requiring "forthwith" compliance shall be issued for removal of storage to a weight which is safe for structural load notification to FPB
115
TB054 HAZARDOUS/ILLEGAL MEZZANINES Any questions concerning mezzanines may be telephoned to?
NORTH INDUSTRIAL AND COMMERCIAL SECTION UNIT OF FPB
116
TB156 HILLSIDE HOME SF How many hillside structures are there in the city?
over 400,000
117
TB156 HILLSIDE HOME SF What are the 3 categories of hillside homes?
1) DESCENDING 2) ASCENDING 3) CANTILEVER
118
TB156 HILLSIDE HOME SF What are three characteristic design features of DESCENDING hillside homes?
1) large picture windows 2) cantilever balconies off lowest level 3) walkout balconies
119
TB156 HILLSIDE HOME SF Why are descending hillside homes the most dangerous?
possibility that entry from grade level into the structure could place ff above the fire if it originates on a lower floor
120
TB004 What are the three types of vehicle tank configurations?
1) Single tank with 2 or 3 axles 2) Tank tractor with semi trailer connected by 5th wheel 3) Tank truck pulling 2 axle trailer
121
TB004 What are the capacities of the three types of vehicle tanks configurations?
1) Single tank 3,000 gal; 5,000 gal 2) Tank tractor with semi trailer: 9,000 gal 3) tank truck pulling 2 axle trailer 4,200+ 4,8000=9,000
122
TB004 Where is the tank walls the thickest?
Towards the bottom (3/16") and get thinner on the top
123
TB004 Void spaces between bulkheads are for leak indicator holes, can contain how much product?
up to 200 gal
124
TB004 When can you use PLAIN water on gasoline tanker incidents with fire involving spilled products or tanker?
for performing a rescue
125
TB004 What type of foam should be used?
AR AFFF Alcohol Resistive Aqueous Film Forming Foam
126
TB004 How much foam concentrate shall be planned for fire suppression? maintaining a foam blanket?
15 min supply; extra 15 min supply
127
TB004 How much class b foam do foam tenders carry?
1000 gal
128
TB004 Aluminum Tanks melt at what temp?
1,200 deg f
129
TB004 What rate will gasoline burn?
about one foot an hour
130
TB004 When should you attempt to upright a tank trailer before it has been off loaded?
NEVER
131
TB004 What is the safest and quickest method of off loading an overturned tanker?
Drilling a 4" hole in the aluminum tank with pneumatic drill
132
TB004 Vacuum Trucks hold how much of their rated capacity?
90%
133
TB004 Vacuum Trucks are classified by what 3 standards?
Dirty-tank is empty, but not cleaned Clean-tank is empty and washed with water Super Clean- chemically cleaned and free of product
134
TB004 Exhausted concentrated gasoline vapors are how much heavier than air?
3-4x
135
TB005 Hydraulic bumpers can be pressurized to what psi?
150psi
136
TB005 What is the travel distance of hydraulic bumpers? mechanical?
3" 4"
137
TB005 When breaking windows, where should you strike the glass?
corners
138
TB005 What is the flash point and specific gravity of GASOLINE?
-45deg F 0.8
139
TB005 What is the flash point and specific gravity of DIESEL?
125deg F less than 1.0
140
TB007 What are the physical differences between straight streams and spray streams?
Size of water droplets Shape of the stream Effective reach
141
TB007 What is the expansion ratio of water to steam?
1:1700
142
TB007 What is "Skin Friction?"
Friction between air and water as water travels toward the fire
143
TB010 What are the dimensions of the bridle?
4 sections of 1/8" steel cable 4 1/2' long
144
TB010 Helicopters use what size tagline that separates at how many pounds?
1"x 200' 80lbs
145
TB010 How much does 3 sections of 2 1/2" hose weight?
180lbs
146
TB012 What percent of fires are held in check by sprinklers?
96%
147
TB012 How many sprinklers are in a JUNIOR SYSTEM?
2-4
148
TB012 What is the orifice size of sprinklers in a JUNIOR SYSTEM?
1/4" to 3/8"
149
TB016 Siphon Ejectors are referenced by what?
Inlet size
150
TB020 Proper vehicle operation, use, maintenance, and trip planning can cause up to how much fuel conservation?
up to 10%
151
TB027 What is the ratio of "light water" to water?
6% concentrate 94% water (1 gal to 16 gal)
152
TB027 How many time more effective is "light water" than protein type foams on open surface gasoline fires?
3x
153
TB031 Lexan softens at what temp?
350deg
154
TB065 Combined use of radios and MDT draw how many amps per hour?
8
155
TB065 When should an apparatus radio cutoff switch be turned "OFF?"
When placed out of service and cannot be plugged in for over 10 hours
156
TB008 WHAT IS CURRENT FLOW OR ELECTRON FLOW?
AMPS (GPM)
157
TB008 WHAT IS THE DIFFERENCE IN ELECTRICAL POTENTIAL BETWEEN TWO POINTS IN A CIRCUIT?
VOLTAGE (PSI)
158
TB008 WHAT IS A MEASUREMENT OF RESISTANCE?
OHMS (FL)
159
TB008 OHMS LAW
WATTS=VOLTSXAMPS
160
TB008 WHAT IS EXTREMELY HIGH VOLTAGE?
EXCESS OF 60,000 VOLTS
161
TB008 HIGH VOLTAGE IS 600-59,999 VOLTS AND IS REFERRED TO AS "PRIMARIES" OR?
PRIMARY CIRCUIT VOLTAGE
162
TB008 LOW VOLTAGE IS UNDER 600 VOLTS AND IS REFERRED TO?
SECONDARIES
163
TB008 HOW DOES ELECTRICITY GET TO CONSUMERS?
1) GENERATION 2) TRANSMISSION 3) DISTRIBUTION
164
TB008 GENERATION FACILITIES CREATE HOW MUCH ELECTRICITY?
4,000-20,000 VOLTS
165
TB008 WHAT TAKES ELECTRICITY FROM GENERATION PLANTS AND BEGINS THE FLOW OF CURRENT OVER LONG DISTANCES OVER TRANSMISSION LINES?
SWITCHYARDS
166
TB008 WHAT ARE 2 MAIN COMPONENTS OF THE TRANSMISSION SYSTEM?
GRIDS; TRANSMISSION LINES
167
TB008 WHAT IS THE RANGE OF VOLTAGE FOR TRANSMISSION LINES? COMING IN TO LA?
69KV-OVER 100KV 230KV OR HIGHER IN LA
168
TB008 HOW LONG CAN TRANSMISSION INSULATORS BE?
3-20 FEET
169
TB008 DISTRIBUTION LINES STEP ___VOLTAGE WHILE STEPPING___ AMPS WITH TRANSFORMERS?
DOWN/UP
170
TB008 HOW MANY TIMES IS VOLTAGE STEPPED DOWN IN THE DISTRIBUTION SYSTEM BEFORE IT IS REACHED TO CUSTOMERS?
3X
171
TB008 LADWP DISTRIBUTION STATIONS ARE SUBSTATIONS THAT UTILIZE TRANSFORMERS TO CHANGE HIGH VOLTAGE ELECTRICITY TO LOWER VOLTAGE. WHERE DOES THIS PROCESS START?
RECIEVING STATIONS
172
TB008 LADWP HAS HOW MANY RECEIVING STATIONS?
21
173
TB008 WHAT IS SUB-TRANSMISSION VOLTAGE?
34.5KV
174
TB008 HOW MUCH IS PRIMARY CIRCUIT VOLTAGE?
4.8KV
175
TB008 PRIMARY LINES RUN FROM WHERE TO WHERE?
DISTRIBUTION STATION TO NEIGHBORHOOD IT SERVES
176
TB008 EACH PRIMARY LINE SERVES HOW MANY CUSTOMERS?
750
177
TB008 LARGE COMMERCIAL OR INDUSTRIAL CONSUMERS, SUCH AS HOSPITALS, MALLS, HIGH RISE BUILDINGS, METRO RAIL STATIONS, AND LARGE COMPLEX USE WHAT VOLTAGE?
34.5KV
178
TB008 WHAT IS USED TO INCREASE OR DECREASE THE VOLTAGE OF ELECTRICAL CURRENT?
DISTRIBUTION TRANSFORMERS
179
TB008 HIGH VOLTAGE CAPACITORS HAVE BEEN KNOWN TO RETAIN A DEADLY ELECTRICAL CHARGE HOW LONG AFTER THE POWER HAS BEEN SHUT DOWN?
WEEKS
180
TB008 WHAT IS THE MOST COMMON DISTRIBUTION TRANSFORMER?
POLE MOUNTED
181
TB008 WHAT ARE CONDUCTORS MADE OF?
PORCELIN OR GLASS
182
TB008 HOW CAN YOU DETERMINE HIGH VOLTAGE?
1) HIGH VOLTAGE SIGNS 2) SIZE AND SHAPE OF INSULATORS 3) DISTANCE BETWEEN CONDUCTORS
183
TB008 HOW MANY AMPS CAN CAUSE DEATH?
1/10TH FOR 2 SEC
184
TB008 WET SKIN HAS A RESISTANCE OF ?
1,000OHMS
185
TB008 DO RUBBER TIRES INSULATE THE APPARATUS?
NO
186
TB008 WHEN RESPONDING TO DOWNED POWER LINES OR POLES, SPOT APPARATUS HOW FAR?
AT LEAST ONE SPAN (POLE TO POLE)
187
TB008 WHAT IS THE VOLTAGE FOR STREET LIGHTS?
120-6150
188
TB008 WHEN DIRECTING HOSE STREAMS ON A POWER POLE, WHAT IS THE 30/33/100 RULE?
30 DEG FOG PATTERN 33 FEET AWAY 100PSI
189
TB008 HOW MANY DISTRIBUTION STATIONS ARE IN THE CITY?
150
190
TB008 ELECTRICAL HAZARD IDENTIFICATION USING 3 STRANDS OF BARRIER TAPE THAT SAYS WHAT?
"DO NOT ENTER" "DO NOT CROSS"
191
TB008 HOW FAR SHOULD YOU BE FROM TRANSMISSION TOWERS?
35 FEET
192
TB008 MAINTAIN A CLEARANCE OF HOW MANY FEET BEYOND THE OUTERMOST WIRE OF ELECTRICAL TRANSMISSION LINES?
100FT
193
TB008 WHAT IS MOST LIKELY BURNING IN AN ELECTRICAL VAULT OR MANHOLE FIRE?
CONDUIT
194
TB008 WHAT IS THE EXPLOSIVE RANGE FOR CARBON MONIXIDE?
12.5 TO 74%
195
TB008 HOW MUCH DO MANHOLE COVERS WEIGH?
300LBS
196
TB008 MANHOLE COVERS HAVE BEEN BLOWN HOW MANY FEET IN THE AIR AND HOW FAR?
75' IN THE AIR 125' AWAY
197
TB055 4" SUPPLY HOSE IS ______ JACKET 100% OZONE RESISTANT HOSE?
SINGLE
198
TB055 4" SUPPLY HOSE IS SYNTHETIC HOSE HIGH TENSILE REINFORCED YARN CIRCULAR WOVEN IN WHAT CONFIGURATION?
TWILL
199
TB055 SYNTHETIC HOSE PROVIDES MAXIMUM HOSE FLEXIBILITY AND ELIMINATES WHAT?
LEFT HAND TWIST
200
TB055 WHAT IS USED FOR THE WARP AND WOOF?
POLYESTER FOR WARP NYLON FOR WOOF
201
TB055 WHY IS THE 4" SUPPLY HOSE YELLOW?
FOR VISIBILITY
202
TB055 WHAT ELIMINATES DELAMINATION FOUND IN LAYERED HOSES?
"THROUGH THE WEAVE" EXTRUSION PROCESS
203
TB055 HOW MUCH DOES ONE 50' SECTION OF 4" WEIGH?
49LBS
204
TB055 HOW DO YOU IDENTIFY THE HOSE?
ID WITH 1 1/2" STENCILS 6" FROM COUPLINGS
205
TB055 WHAT IS THE BURST PRESSURE OF THE 4"?
750PSI
206
TB055 WHAT IS THE ACCEPTANCE PRESSURE?
500PSI
207
TB055 WHAT IS THE SERVICE TEST?
300PSI
208
TB055 WHAT IS THE KINK PROOF?
375PSI
209
TB055 DOES EXPOSURE TO SEA WATER, OIL OR CONTAMINANTS HAVE ANY EFFECT ON THE HOSE?
NO EFFECT
210
TB055 DRIVE OVER THE HOSE AT WHAT ANGLE?
45 DEGREE
211
TB055 WHEN LOADING HOSE IN HOSEBED, LOAD EITHER?
ROLLED OR OVER THE BAR
212
TB062 WHAT IS THE PRIMARY OBJECTIVE OF THE FIRST COMPANY?
GET ONE HOSE LINE IN PLACE
213
TB062 THE 2" HIGH RISE HOSE IS SINGLE JACKET, NITRILE RUBBER IMPREGNATED WITH WHAT?
SYNTHETIC YARN
214
TB062 THE 2" HIGH RISE HOSE IS RIBBED TO REDUCE WEAR AND?
INCREASE GRIP
215
TB062 HOW MANY INCHES CAN THE HIGH RISE HOSE BE BENT BEFORE IT WILL KINK?
12"
216
TB062 HOW MUCH DOES THE HOSE WEIGH COMPARED TO THE 2 1/2" THAT WEIGHS 64LBS?
38LBS
217
TB062 HOW MUCH DOES THE PIGTAIL WEIGH?
10LBS
218
TB062 EACH PIGTAIL IS HOW LONG OF 2 1/2" HOSE?
8 FT
219
TB062 WHAT DEGREE IS THE 2 1/2" ELBOW?
60 DEG
220
TB062 HOW MUCH TALLER IS THE SINGLE LAYER COMPARED TO THE DOUBLE LAYERING?
8 INCHES
221
TB062 WHEN STARTING TO REBUILD THE HOSE PACK, HOW FAR BACK DO YOU PLACE THE FEMALE COUPLING?
10" PAST GAUGE
222
TB062 LADDER STRAPS ARE PLAED HOW FAR FROM BOTTOM OF PACK?
8"
223
TB062 HOW BIG ARE THE FOOTPRINT OF THE HOSE PACKS?
SINGLE: 40X22 DOUBLE: 32X16
224
TB062 WHERE MAY YOU ENCOUNTER 2 1/2" HOSE CABINETS?
IN STAIRWELLS ABOVE 4TH FLOOR
225
TB062 ORIFICE PLATES LIMIT YOU TO WHAT?
200GPM AT 50PSI
226
TB062 HOW MANY TURNS DO YOU OPEN VALVE ONCE YOU REMOVE ORIFICE PLATES?
1 1/2 TURNS AND ADJUST FROM THERE
227
TB062 ORIFICE PLATES ARE USED FROM THE TOP WHAT FLOORS?
6 TO 8
228
TB062 WHEN ARE PRV'S FOUND?
PRESSURES EXCEED 150LBS
229
TB062 WHERE ARE ORIFICE PLATES LOCATED?
SOLDERED TO OUTLET; MALE END OF DRIPCOCK; BEHIND GASKET ON DRIPCOCK; BEHIND GASKET ON 2 1/2" HOSE
230
TB062 THE 2" HOSE IS ____ SUSCEPTIBLE TO DAMAGE?
MORE
231
TB062 WHAT IS THE 2" HOSE TESTED AT?
300PSI
232
TB063 HOW MUCH PRESSURE IS REQUIRED AT THE HIGHEST OUTLET?
125PSI
233
TB063 WHAT IS THE QUICKEST AND MOST RELIABLE WAY TO IDENTIFY SYSTEM PRESSURE?
LOCATE THE FDC SIGN, MOUNTED NEAR INLETS
234
TB063 AT MINIMUM, THE FDC SIGN MUST CONTAIN WHAT INFORMATION?
1) SYSTEM PRESSURE 2) AREA BUILDING SERVED 3) ADDRESS
235
TB063 WHAT IS THE FORMULA FOR CALCULATING SYSTEM PRESSURE?
OF FLOORS X 5 + 150 CONSTANT (ROOF + STANDPIPE)
236
TB063 200 SERIES ENGINEER WILL LAY?
HYDRANT TO FIRE
237
TB063 MAXIMUM LENGTH OF (2) 2 1/2" LINES INTO THE FDC IS?
100'
238
TB063 WHEN PUMPING OVER 300PSI WHERE DO YOU STRAP THE LINES?
EACH SIDE OF THE COUPLING AND MIDWAY BETWEEN EACH COUPLING; LOADING LINES BEFORE STRAPPING
239
TB063 WHEN WILL ANOTHER APPARATUS SPOT TO THE HYDRANT/4 WAY AND PUMP HALF THE SYSTEM PRESSURE TO THE APPARATUS SUPPLYING THE FDC?
OVER 20 STORIES OR 25OPSI
240
TB063 WHEN YOU ARE NOT FLOWING WATER, MONITOR THE PUMP TEMPERATURE. USE WHAT TO ALLEVIATE WATER IN THE PUMP FROM HEATING UP?
PAVEMENT COOLER
241
TB063 HOW WOULD YOU KNOW IF YOU ARE FLOWING WATER INTO THE SYSTEM?
FEATHER THE DISCHARGE GATE. IF GATE RESISTS AND/OR THERE IS A DROP ON DISCHARGE GAUGE THEN WATER IS FLOWING
242
TB063 WHAT DO YOU DO WHEN IT IS CONFIRMED WATER FLOWING INTO THE INLETS?
THROTTLE UP AND NOTIFY IC
243
TB063 WHEN WATER IS FLOWING, WHAT SHOULD IC REQUEST?
ADDITIONAL ENGINES TO DUPLICATE THE LAY USING THE ADDITIONAL INLETS AND USE A SEPARATE SOURCE OF WATER IF POSSIBLE
244
TB063 WHAT DOES DUPLICATING THE LAY PROVIDE?
ADDITIONAL GPM AND INCREASED RELIABILITY
245
TB063 HAVING A TRUCK COMPANY SPOT THEIR AERIAL AS TO COVER BOTH THE PANEL AND THE FDCS. ONCE SPOTTED, LAY SALVAGE COVERS FOLED TO WHAT WIDTH ON THE RUNGS FROM THE PEDESTAL TO THE TOP OF THE AERIAL?
1/4
246
TB063 SPOTTING A SECOND APPARATUS NEXT TO YOUR ENGINE AND USING WHAT TWO PIECES OF EQUIPMENT TO CREATE A ROOF OVER THE PANEL?
PIKE POLE AND SALVAGE COVER
247
TB085 WHAT DOES THE DIVERTER DO?
DIRECTS FLOW 90 DEG FROM INLET TO OUTLET
248
TB085 WHAT IS THE MAIN BODY, COVER AND DIVERTER MADE OF?
MACHINED ALUMINUM
249
TB085 WHAT IS THE WEIGHT OF 4 WAY?
35LBS
250
TB085 WHAT IS THE LENGTH, WIDTH, AND HEIGHT OF 4 WAY?
L: 12-3/4" W: 14" H: 13-1/2"
251
TB085 HAND WHEEL CAN BE OPERATED AT HIGH PSI BUT WHAT IS RECOMMENDED?
IDLE
252
TB085 THE 4 WAY IS HYDROSTATICALLY TESTED AT WHAT PSI AND WHEN?
ANNUAL PUMP TEST AT 900PSI
253
TB106 WHAT IS LLCCESS?
LOOKOUT LOCATION COMMUNICATIONS CONDITIONS ESCAPE ROUTES SAFETY ZONES SAFETY EQUIPMENT
254
TB106 WHAT IS THE SIGN FOR OPERATIONAL RETREAT?
10 SEC OF AIR HORN FOLLOWED BY 10 SEC OF SILENCE X3 FOR A TOTAL OF 50 SEC
255
TB106 FACADES AND MEZZANINES ARE _______ ABOVE ROLLING STEEL DOORS?
NO NORMALLY
256
TB127 WHAT IS THE BEST METHOD OF VISUAL AND TACTICAL INSPECTION?
CLEANING
257
TB127 EACH STATION IS REQUIRED TO CREATE A STORMWATER POLLUTION PREVENTION PLAN. WHERE SHALL IT BE POSTED?
BULLETIN BOARD
258
TB127 WHO SHOULD PROVIDE CAV TIME?
COMPANY COMMANDERS AND BC
259
TB127 WHAT CHEMICALS SHALL BE PROHIBITED?
ANY EQUIPMENT THAT CREATES AN AEROSOL SPRAY OF ANY FLAMMABLE LIQUIDS; KEROSENE
260
TB127 PRESSURE WASHERS FORCE WHAT OUT?
GREASE OUT OF AREAS
261
TB127 WHEN SHOULD PROMPT LUBRICATION BE DONE?
SAME DAY OF CLEANING AND IN NO CASE LATER THAN THE NEXT DAY
262
TB127 IN TERMS OF LUBE, IN MOST CASES?
TOO LITTLE IS FAR WORSE THAN TOO MUCH
263
TB127 WHAT IS USED TO LUBE CHASSIS?
CHEVRON BLACK PEARL
264
TB127 WHEN USING POWER LUBE EQUIPMENT, WHAT IS THE MAX AIR PRESSURE?
60PSI
265
TB127 WHAT SHOULD BE WIPED CLEAN PRIOR TO LUBING TO PREVENT FORCING CONTAMINANTS INTO AREA BEING LUBRICATED?
ALEMITE OR ZERK FITTINGS
266
TB127 WHAT IS USED TO LUBE FIRE PUMPS?
AQUA LUBE
267
TB127 WHAT TYPE OF ENGINE OIL IS USED?
15-40
268
TB127 WHO HANDLES TRANSMISSION OIL AND DIFFERENTIAL OIL?
THE SHOPS
269
TB127 HIGH QUALITY PAINT PROVIDES WHAT?
PROTECTION FOR LIFE
270
TB127 MEMBERS SHALL NOT PAINT UNDERCARRIAGE, EXCEPT?
TO BARE METAL AND TO PROTECT SURFACES FROM CORROSION
271
TB127 WHO IS ALLOWED TO USE SPRAY PAINT?
SHOPS ONLY
272
TB127 WHEN WILL UNDERCARRIAGE PAINT BE INSPECTED AND BY WHOM?
ANNUALLY AT PUMP TEST BY S&M
273
TB127 INSPECTION STANDARDS PRIMARY FOCUS WILL BE?
MAINTAINED AND CLEAN SERVICEABLE CONDITION SAFE READY TO RESPOND
274
TB127 INSPECTION IS A MEANS TO VERIFY?
PROPER PREVENTATIVE MAINTENANCE; DOCUMENTATION IS BEING PERFORMED
275
TB127 THE MOST TELLING INDICATOR OF PRIDE IS?
CONDITION OF TOOLS AND EQUIPMENT
276
TB127 APPARATUS INSPECTION IS DIVIDED INTO WHAT 4 CATEGORIES?
1) INSPECTION OF RECORDS; 2) DRIVERS KNOWLEDGE OF APPARATUS; 3)DRIVERS KNOWLEDGE WHEN MAINTENANCE WAS PERFORMED; 4) PHYSICAL INSPECTION
277
TB127 BIMONTHLY INSPECTION IS CONDUCTED BY WHO?
CAPTAIN AND BC
278
TB127 WHO SCHEDULES BI MONTHLY INSPECTION AND BY WHEN?
BC BY THE FIRST 2 WEEKS OF EVEN MONTHS
279
TB127 WHO SCHEDULES 4 MONTH UNDERCARRIAGE?
S&M; WITH SUBSEQUENT INSPECTIONS SCHEDULED BY BC
280
TB127 F978 IS DOCUMENTED BY WHOM? 978B?
CAPTAIN AND BC; BC
281
TB127 WHO SCHEDULES PUMP/AERIAL TEST?
S&M
282
TB127 WHO SCHEDULES BI ENNIAL INSPECTION?
COMMANDER, BES
283
TB127 FOR COMMUNITY DESIGNATORS, WHAT MUST BE ON FILE?
APPROVED LETTER
284
TB127 WHEN SHOULD YOU REPORT ANY TEARS OR HOLES IN THE BOOTS OF TAK4 INDEPENDENT FRONT SUSPENSION?
PROMPTLY
285
TB127 THE F972 DAILY PRE TRIP INSPECTION FORM SHALL BE CONDUCTED WHEN?
AS SOON AS PRACTICAL FOLLOWING RELIEF
286
TB127 F 972 SHALL BE RETAINED FOR HOW LONG?
RETAIN IN LOG BOOK, ONE MONTH PAST LAST ENTRY
287
TB127 F 972 SATISFIES WHAT TITLE IN CCR?
TITLE 13 OF CCR 1215
288
TB127 AIR COMPRESSOR SHALL CUT IN AT WHAT PSI?
85; 100 TYPICALLY FOR LAFD
289
TB127 NORMAL CUT OUT PRESSURE IS BETWEEN WHAT PSI WITH A MAX OF ?
110-120; 130
290
TB127 LOW PRESSURE WARNING DEVICE MUST ACTIVATE BETWEEN WHAT PSI?
55-75
291
TB127 F-977 F-978 F-978B F-979 ARE RETAINED FOR HOW LONG?
3 YEARS
292
TB127 APPARATUS IS DELIVERED TO S&M FOR WHAT 5 REASONS?
1) ANNUAL TEST; CLEAN LADDERS AT LEAST 2 WEEKS PRIOR 2) SCHEDULED REPAIRS 3) UNSCHEDULED REPAIRS (EMERGENCY) 4) ROUTINE LUBRICATION 5) ACCIDENTS
293
TB127 WHAT IS THE MAXIMUM SPEED LIMIT AT MTA YARDS?
8MPH OR POSTED SPEED LIMIT
294
TB127 WHEN AT THE MTA YARD, WHAT MUST BE WORN?
REFLECTIVE SAFETY VEST; BRUSH JACKET
295
TB127 BODY ARMOR ISSUED AFTER WHAT YEAR IS ROLLED AND STORED IN CARRYING BAG?
2005
296
TB127 WHAT PART OF THE YARD SHOULD OFFICERS CHECK?
WHERE UNDERCARRIAGE WAS CLEANED
297
TB135 WHAT IS T.H.RE.A.T.
T=THREAT SUPRESSION H=HEMORRAGE CONTROL RE=RAPID EXTRACTION A=ASSESSMENT BY EMS T=TRANSPORT TO DEFINITIVE CARE
298
TB135 WHAT IS AN ACTIVE SHOOTER RESPONSE?
2 BC 2 EMS 1 COMMAND POST CO 1 LF 2 E 4 ALS RA 2 800
299
TB135 THE FIRST ARRIVING OFFICER SHALL: CONFIRM NATURE OF INCIDENT (AS VS SHOOTING) PROVIDE SIZE UP AND?
DESIGNATE A STAGING AREA
300
TB135 WHO WILL MEET WITH LAW ENFORCEMENT AND ESTABLISH UNIFIED COMMAND?
FIRST ARRIVING BC
301
TB135 WHO WILL NORMALLY BE ASSIGNED RESCUE GROUP SUP?
SECOND BC
302
TB135 WHO SHOULD BE MEDICAL COMMUNICATIONS?
1ST EMS
303
TB135 WHO SHOULD BE MEDICAL GROUP SUP?
SECOND ARRIVING EMS
304
TB135 FIRST ARRIVING FIRE COMPANY AND RA SHOULD?
PREPARE EQUIPMENT AND PERSONNEL FOR DEPLOYMENT AS RTF
305
TB135 COMPLEX INCIDENT SHALL HAVE WHAT DEVELOPED?
UNIFIED COMMAND IAP
306
TB135 IAP SHALL INCLUDE WHAT?
RESCUE GROUP MEDICAL GROUP FIRE GROUP COMMS PLAN
307
TB135 IF NO WARM ZONE OR CCP EXISTS, WHO WILL COORDINATE MOVEMENT OF PATIENTS TO TREATMENT AREAS?
TRIAGE UNIT LEADER
308
TB135 TREATMENT AREAS ARE IN WHAT ZONE?
COLD
309
TB135 WHAT CAN BE USED WHEN NO OTHER OPTIONS ARE AVAILABLE WHEN IT IS UNSAFE FOR FIREFIGHTERS TO CONTROL THE SPREAD OF FIRE?
HELICOPTER WATER DROPS
310
TB135 AT A MINIMUM, WHAT IS THE PERSONNEL FOR A RTF?
2 FF 2 FORCE PROTECTION OFFICERS; WHEN POSSIBLE 1FFPM
311
TB135 BALLISTIC HELMETS ARE IDENTIFIED WITH COMPANY DESIGNATOR WITH VELCRO LOCATED WHERE?
BACK OF HELMET
312
TB135 WHAT ARE THE 3 TIERS OF TEMS?
TIER 3: TEMS FRO 4 HOURS MIN/YEAR ALL MEMBERS TIER 2: TEMS TECHNICIAN TEMS COURSE NO SWAT TIER 1: TEMS SPECIALIST 40HR TEMS COURSE+ 80HR SWAT COURSE
313
TB135 WHEN RESPONDING TO AN ACTIVE SHOOTER INCIDENT, LAW ENFORCEMENT ARE TRAINED TO USE WHAT TACTIC?
IMMEDIATE ACTION/RAPID DEPLOYMENT
314
TB139 WHAT NFPA STANDARD IS AIR MANAGEMENT?
1404
315
TB139 AIR MANAGEMENT DRILL SHALL BE DONE IN WHAT MONTH?
JANUARY
316
TB139 WHERE SHALL COMPANY COMMANDERS DOCUMENT AIR MANAGEMENT TRAINING?
PRB 393 F2
317
TB145 COMBUSTABLE METALS ARE CLASSIFIED AS WHAT TYPE OF FIRE?
CLASS D
318
TB145 COMBUSTABLE METAL FIRES CAN RANGE FROM WHAT TEMPERATURES?
5000-9000 DEG
319
TB145 HYDROGEN BECOMES A FREE BURNING CELL AND OXYGEN BECOMES WHAT?
AN OXIDIZER THAT ACCELERATES THE BURNING RATE, FIRE SPREAD, AND TEMPERATURE
320
TB145 COMBUSTABLE METALS ARE CATEGORIZED INTO WHAT TWO CATEGORIES?
ALKALI METALS ALKALI EARTH METALS
321
TB145 ALKALI METALS ARE LITHIUM, SODIUM AND?
POTASSIUM
322
TB145 ALKALI METALS ARE WHAT UNDER NON FIRE CONDITIONS AND APPLYING WATER WILL RESULT IN FIRE AND EXTREME REACTIONS?
WATER REACTIVE
323
TB145 ALKALI METALS SHOULD BE PLACARDED WITH WHAT UNDER NFPA 704 SYSTEM?
"W"
324
TB145 ALKALI EARTH METALS ARE MAGNESIUM AND ALUMINUM WITH WHAT TWO THAT ARE TRANSITIONAL METALS?
TITANIUM ZIRCONIUM
325
TB145 ALKALI EARTH METALS DO NOT PRESENT THE SAME HAZARDS AS ALKALI METALS, BUT WHEN BURNING THEY CAN BE _______WHEN IN CONTACT WITH WATER?
EXTREMELY DANGEROUS
326
TB145 "M" CATEGORIES ON NFPA704 PLACARDING ARE FOR THE FOLLOWING METALS?
TITANIUM MAGNESIUM ZIRCONIUM ALUMINUM
327
TB145 "M" SHALL BE IN THE FOURTH SPACE ON THE NFPA DIAMOND WHEN QUANTITIES EXCEED HOW MANY POUNDS OF COMBUSTABLE METALS?
500LBS
328
TB145 WHAT HAPPENS WHEN MULTIPLE HAZARDS EXIST ON NFPA 704 PLACARD?
MOST SEVERE HAZARD ON TOP AND METALS ALWAYS ON BOTTOM
329
TB145 MEMBERS SHALL BE FULLY ENCAPSULATED WITH SCBA WHEN WORKING WITHIN HOW MANY FEET OF BURNING METALS?
30' IDLH
330
TB145 WHAT IS THE EXTINGUISHMENT METHOD FOR COMBUSTABLE METALS?
SMOTHERING
331
TB145 WHAT DRY POWDER IS THE ONLY APPROVED PRODUCT BY THE LAFD?
MET L X
332
TB145 HOW MUCH MET L X DOES THE SHOPS HAVE?
500LBS
333
TB145 PER THE MANUFACTURES RECOMMENDATION, HOW MUCH MET L X IS REQUIRED TO TO EFFECTIVELY SMOTHER A FIRE?
1" LAYER
334
TB145 HOW MUCH WATER IN A COURSE STREAM CAN BE EFFECTIVE ON CERTAIN TYPES OF COMBUSTABLE METALS IN SMALL QUANTITIES?
COPIUS AMOUNT
335
TB145 WHAT IS THE BEST COURSE OF ACTION IN FIGHTING COMBUSTABLE METAL FIRES?
SEPARATE ISOLATE EXTINGUISH
336
TB145 IT IS EXTREMELY IMPORTANT TO NOT DISRUPT THE CRUST UNTIL THE METAL HAS BEEN COMPLETELY OXIDIZED TO THE POINT OF EXTINGUISHMENT. DEPENDING ON SIZE AND AMOUNT OF PRODUCT, HOW LONG COULD THIS TAKE?
24 HOURS OR LONGER
337
TB150 WHAT 5 GASES DOES THE DRAEGER MONITOR?
CO, CARBON MONOXIDE O2, OXYGEN H2S, HYDROGEN SULFIDE HCN, HYDROGEN CYANIDE EXPLOSIVE VAPORS
338
TB150 DRAEGER IS INTRINSICALLY SAFE, RESISTANT TO ELECTROMAGNETIC INTERFERENCE, IT IS ALSO SAFE AGAINST?
WATER AND DUST
339
TB150 WHAT TYPE OF CALIBRATION IS DONE BY FIELD PERSONNEL?
FRESH AIR
340
TB150 HM SQUADS PERFORM A GAS CALIBRATION HOW OFTEN?
EVERY 6 MONTHS OR ANYTIME SENSOR INDICATES A PROBLEM
341
TB150 ELECTROMAGNETIC SENSORS ARE DISPLAYED IN WHAT UNITS?
PPM
342
TB150 WHAT HAPPENS IF AN "X" IS DISPLAYED ON UPPER R HAND CORNER OF THE SCREEN UPON START UP?
METER CANNOT BE USED
343
TB150 DO NOT STORE DRAEGER NEAR?
SILICONE SPRAY
344
TB150 CATALYTIC COMBUSTABLE SENSOR MAY READ INCORRECT IN ATMOSPHERES LESS THAN ___ OXYGEN BECAUSE THE SENSOR REQUIRES OXYGEN TO BURN COMBUSTABLE VAPORS?
10%
345
TB150 IF OXYGEN IS GREATER THAN ___, IT IS NOT SAFE AND YOU MUST LEAVE?
23.5%
346
TB150 WHAT IS HYDROGENS FLAMMABILITY RANGE?
4-75%
347
TB150 WHAT IS ACETYLENES FLAMMABILITY RANGE?
2.5-100%
348
TB150 WHAT DO YOU DO IF YOU SUSPECT THE PRESENCE OF GAS?
EXIT BUILDING REQUEST HAZ MAT
349
TB150 WHAT IS METHANES FLAMMABILITY RANGE AND LOWER LIMIT?
5-15% 5%
350
TB150 ALARM 1GOES OFF AT?
10% LEL
351
TB150 ALARM 2 GOES OFF AT?
20% LEL
352
TB150 PRESS AND HOLD "OK" KEY FOR 3 SEC WILL DO WHAT?
TURN ON DEVICE
353
TB150 HOW DO YOU TURN OFF DEVICE?
PRESS AND HOLD OK AND + BUTTONS AND COUNTDOWN BEGINS
354
TB150 IT ATMOSPHERE CAUSES METER TO ACTIVATE ALARM, WHAT SHALL YOU DO?
LEAVE IMMEDIATELY
355
TB150 HOLDING OK BUTTON FOR 2 SEC WILL DO WHAT?
DISPLAY VALUES
356
TB150 HOW DO YOU CLEAR PEAK VALUES?
PRESS + 3X SELECT TRIANGLE ICON B PRESSING + THEN THE OK BUTTON HOLD OK FOR 5 SEC TO CLEAR
357
TB150 FRESH AIR CALIBRATION IS USED TO IMPROVE ZERO POINT ACCURACY. O2 SENSOR IS AT ___? WHILE ALL OTHERS ARE AT 0%
20.9%
358
TB150 HOW DO YOU PERFORM A FRESH AIR CALIBRATION?
AFTER WARMED UP, DEPRESS + 3X SELECT FRESH AIR SYMBOL PRESS OK WAIT 5 SEC OR PRESS OK
359
TB150 ALARM WILL RESET IF CONCENTRATION DROPS BELOW ALARM THRESHOLD. PRESS WHAT TO SWITCH OFF ALARMS?
OK
360
TB150 A BATTERY ALARM WILL SOUND WHEN 1/3 OF BATTERY FULL SYMBOL WILL FLASH ON R SIDE OF DISPLAY. PRESS OK TO ACKNOWLEDGE ALARM. HOW LONG WILL THE BATTERY LAST?
20 MIN
361
TB150 REPLACE BATTERIES WITH 2 AA. BATTERIES LAST APPROX 2-3 WEEKS. HOW LONG WILL IT TAKE TO WARM UP?
30 MIN
362
TB150 AN EMPTY BATTERY SYMBOL INDICATES?
DEVICE WILL SHUT OFF IN 10 MIN
363
TB150 AFTER EACH USE, CHECK BATTERY STATUS 3/4 FULL. THEN PERFORM WHAT?
FRESH AIR CALIBRATION
364
TB150 WEEKLY, MAINTAIN BATTERY ABOVE 3/4. PERFORM FRESH AIR CALIBRATION AND CLEAN WITH WAHT AS NEEDED?
DAMP SPONGE
365
TB150 HM SQUAD WILL CALIBRATE ALL CHEMICAL SENSORS HOW OFTEN?
EVERY 180 DAYS
366
TB150 WHEN WILL THE DEVICE BE BUMP TESTED?
ANYTIME USED AT AN INCIDENT WHEN READINGS ARE REGISTERED
367
TB151 WHAT IS A DISADVANTAGE TO A SIMPLE HOSE LAY?
WATE FLOW MUST BE STOPPED BEFORE IT CAN BE EXTENDED WITH ADDITIONAL HOSE
368
TB151 A PROGRESSIVE HOSE LAY ALLOWS FOR _______ WATER APPLICATION WHILE EXTENDING THE LAY AND ALLOWS FOR A SERIES OF LATERAL JUNCTIONS AT 100' INTERVALS?
CONTINUOUS
369
TB151 THE "MAIN" LINE BEING PROGRESSIVELY EXTENDED AROUND THE PERIMETER IS KNOWN AS?
TRUNK LINE
370
TB151 WHAT IS THE MINIMUM SIZE FOR A TRUNK LINE?
1 1/2"
371
TB151 PROGRESSIVE HOSE LAYS HAVE MANY ADVANTAGES, WHAT IS A DISADVANTAGE?
INCREASED FRICTION LOSS DUE TO INCREASED NUMBER OF FITTINGS
372
TB151 WHAT IS THE MINIMUM SIZE HOSE FOR ATTACK AND LATERAL LINES?
1"
373
TB151 A COMPANY TASKED WITH PUTTING IN A PROGRESSIVE HOSE LAY MUST DO A MINIMUM OF HOW MANY DROPS?
3
374
TB151 WHAT IS THE COMPANY COMPLEMENT OF SMOKEY PACKS?
4 + STARTER ROLL
375
TB151 HOW MUCH DOES EACH PACK WEIGH?
26#
376
TB151 DESCRIBE THE HOSE IN THE SMOKEY PACKS?
100' POLYESTER SINGLE JACKETED HOSE WITH POLYURETHANE LINING
377
TB151 HOW MANY FORESTRY ADAPTERS COME WITH A SMOKEY PACK?
2
378
TB151 IN ADDITION TO THE SMOKEY PACKS AND STARTER ROLL, EACH COMPANY WILL RECEIVE HOW MUCH HOSE?
400' SINGLE JACKETED 1" 400' SINGLE JACKETED 1 1/2"
379
TB151 WHEN ASSEMBLING THE STARTER ROLL, WHICH END IS ON TOP AND HOW FAR BACK IS IT BEHIND THE OTHER COUPLING?
MALE; 24"
380
TB151 WHEN LOADING, SECURE THE HOSE EVERY HOW OFTEN UNTIL THE 1" IS COMPLETELY LOADED?
8-10'
381
TB151 WHAT COLOR SHALL FORESTRY ADAPTERS BE PAINTED?
WHITE FOR IDENTIFICATION
382
TB151 WHILE TESTING SINGLE JACKETED HOSE, WHERE SHOULD YOU TEST HOSE?
GRASS OR LIGHT FUEL BED
383
TB151 SINGLE JACKETED HOSE SHALL BE TESTED AT WHAT PSI?
300PSI
384
TB151 SINGLE JACKETED HOSE IS PROFF TESTED AT WHAT PSI?
600PSI
385
TB151 SINGLE JACKETED HOSE IS BURST TESTED AT ?
900PSI
386
TB151 WHAT ARE THE WEIGHTS OF THE SINGLE JACKETED HOSE?
5# 7#
387
TB155 LEADERS INTENT FOR STRUCTURE PROTECTION, FIRST:
FIREFIGHTER SAFETY PUBLIC SAFETY
388
TB155 WHAT WILL DICTATE STRATEGIES THAT WILL BE USED?
FIRE BEHAVIOR AND AVAILABILITY OF RESOURCES
389
TB155 WHICH CONDITION HAS THE MOST POTENTIAL FOR HOUSE TO HOUSE IGNITION?
INTERFACE
390
TB155 WHICH CONDITION IS MORE COMPLEX TO TRIAGE?
INTERMIX
391
TB155 WHAT IS A PREPLANNED AREA WHERE FIREFIGHTERS CAN IMMEDIATELY TAKE REFUGE FOR TEMPORARY SHELTER AND SHORT TERM RELIEF WITHOUT USE OF FIRE SHELTER?
TEMPORARY REFUGE AREA
392
TB155 WHAT ARE THREE STRUCTURE TRIAGE CATEGORIES?
NOT THREATENED THREATENED DEFENSIBLE THREATENED NON DEFENSIBLE
393
TB155 WHICH STRUCTURE TRIAGE CATEGORY HAS TRA AND SAFETY ZONES PRESENT BUT LACKS DEFENSIBLE SPACE THAT REQUIRES FIREFIGHTERS TO PROTECT DURING FIRE FRONT CONTACT?
THREATENED DEFENSIBLE
394
TB155 IN TERMS OF WATER GUIDELINES, HOW MUCH WATER SHOULD YOU KEEP IN RESERVE?
100 GAL
395
TB155 WHAT IS THE DIFFERENCE BETWEEN STRATEGY AND TACTICS?
STRATEGY GIVES A GENERAL PLAN TACTIC IS A SPECIFIC ACTION
396
TB155 WHAT ARE THE SEVEN TACTICAL MANEUVERS?
1) CHECK AND GO 2) PREP AND GO 3) PREP AND DEFEND 4) FIRE FRONT FOLLOW 5) BUMP AND RUN 6) ANCHOR AND HOLD 7) TACTICAL PATROL
397
TB155 WHAT ARE THE MILITARY 5 LEVELS OF ENGAGEMENT
DRAW-D DEFEND/HOLD REINFORCE ADVANCE WITHDRAW DELAY
398
TB155 MINIMUM CLEARANCE AROUND AROUND STRUCTURE?
100'
399
TB155 WHAT IS A GENERAL GUIDELINE FOR PROTECTING A STRUCTURE?
ONE ENGINE PER STRUCTURE; WITH ONE ADDITIONAL ENGINE FOR EVERY 4 STRUCTURES AS A "BACKUP" AND FOR PATROL
400
TB155 WHEN CAN ONE ENGINE PROTECT 2 STRUCTURES?
STRUCTURES THAT ARE CLOSE 50' OR LESS
401
TB155 MAINTAIN A MINIMUM DISTANCE OF HOW MANY FEET FROM TRANSMISSION LINES?
35'
402
TB155 SPOT FIRES OR LOW GROUND FIRES CAN BE FOUGHT WITH HOSE LINES IF HEAVY SMOKE OR FLAME IS NOT WITHIN HOW MANY FEET OF POWER LINES?
100'
403
TB156 THIS TYPE OF HOME IS THE MOST DANGEROUS, MIN OF 2 STORIES, HAS LARGE PICTURE WINDOWS, AND COMMONLY OFFERS CANTILEVER BALCONIES OFF LOWEST LEVEL?
DESCENDING
404
TB156 HOW MANY FEET CAN CANTILEVER HILLSIDE HOMES CANTILEVER OUT?
50-75'
405
TB156 WHEN WERE CANTILEVER HOMES ORIGINALLY BUILT
EARLY 1900'S
406
TB156 WHEN BUILDING FEATURES MAKE IT IMPOSSIBLE TO ATTACK THE FIRE AT OR BELOW THE LOWEST LEVEL OF FIRE INVOLVEMENT, WHAT TACTIC SHOULD BE CONSIDERED?
TRANSITIONAL ATTACK
407
TB156 WHAT MUST BE IN PLACE BEFORE VENTILATING OVER AN UNENCLOSED STAIRWELL?
FIRE SUPPRESSION LINES IN PLACE
408
TB156 WHEN SHOULD HORIZONTAL VENTILATION BE CONSIDERED AS A CONTINGENCY PLAN?
WHEN THE FIRE IS BELOW GRADE AND THE ONLY ENTRY TO ESTABLISH FIRE ATTACK IS FROM THE FIRST FLOOR
409
TB156 WHAT SHOULD BE A FACTOR WHEN DETERMINING THE BEST VENTILATION METHOD?
DIURNAL WINDS
410
TB156 WHY IS PARKING ON THE SAME SIDE AS THE HYDRANT?
FOR SUPPLY LINES TO BE TUCKED UP AGAINST THE PARKED CARS
411
TB156 WHAT IS THE HIGHEST PRIORITY WHEN PERFORMING A 360 ON A HILLSIDE HOME?
IDENTIFYING A PORTAL OF ENTRY
412
TB156 FIRE ATTACK, BACKUP, AND ALL ADDITIONAL RESOURCES SHALL MAKE AN ATTACK FROM A COMMON PORTAL OF ENTRY UNTIL WHEN?
WATER CAN BE PLACED ON THE SEAT OF THE FIRE
413
TB156 WHEN UTILIZING THE TIC, IT IS IMPORTANT TO REALIZE THAT IT ONLY READS?
SURFACE TEMP
414
TB164 WHAT IS A COORDINATED APPLICATION OF WATER WITH A STRAIGHT STREAM FROM THE EXTERIOR THAT PROVIDES A BREAK IN THE FIRE TRIANGLE BY COOLING THE ENVIRONMENT PRIOR TO TRANSITIONING INTO AN OFFENSIVE ATTACK?
TRANSITIONAL ATTACK
415
TB164 WHEN SHOULD TRANSITIONAL ATTACK BE CONSIDERED?
-IMMINENT SIGNS OF FLASHOVER -FIRE CONDITIONS MAKE ACCESS UNSAFE -FORCIBLE ENTRY DELAYED -VENTILATION IS DELAYED OR NONEXISTENT -WATER SUPPLY DELAYED OR INSUFFICIENT -EXCESSIVE STORAGE
416
TB164 WHERE IS WATER APPLIED WHEN UTILIZING TRANSITIONAL ATTACK?
ONLY TO WINDOWS OR DOORS WHERE FIRE IS PRESENT OR VOLATILE SMOKE IMMINENT OF FLASHOVER
417
TB164 CAN YOU USE A TRANSITIONAL ATTACK WITH A WINDOW PANE INTACT?
NO
418
TB164 HOW LONG DO YOU FLOW WATER WHEN UTILIZING A TRANSITIONAL ATTACK?
UNTIL A CHANGE IN CONDITIONS OR BULK OF FIRE KNOCKED DOWN
419
TB164 CAN YOU USE A SWIRLING MOTION OR FOG PATTERN DURING TRANSITIONAL ATTACK?
NO
420
TB174 HOSE TESTING STANDARDS ARE CONSISTENT WITH STANDARDS OF SAFETY, WHAT NFPA?
1962
421
TB174 WHAT HOSE IS TESTED BY THE TESTPIT ENGINEER?
HARD SUCTION HOSE 2 1/2"HIGH PRESSURE HIGH RISE HOSE
422
TB174 WHEN SHOULD NEW AND REPAIRED HOSE BE TESTED?
AS SOON AS POSSIBLE AFTER RECEIPT BY FIRE STATION
423
TB174 WHEN DOES LAFD RECOMMEND TESTING HOSE?
WITHIN 24 HOURS OF DELIVERY
424
TB174 ALL HOSE THAT IS IN SERVICE SHALL BE TESTED OW OFTEN?
ANNUALLY
425
TB174 ALL HOSE THAT HAS BEEN STORED FOR LONGER THAN 1 YEAR SHALL BE WHAT BEFORE PLACED IN SERVICE?
TESTED
426
TB174 WHEN ARE FIREFIGHTING LINES CHANGED WHEN DIRTY OR DAMP?
WITHIN 24 HOURS
427
TB174 FABRIC JACKETED SUPPLY HOSE SHALL BE CHANGED HOW OFTEN?
WEEKLY OR MORE FREQUENTLY IF DAMP OR DIRTY
428
TB174 WHO SHALL THE STATION COMMANDER CONTACT FOR REPLACEMENT HOSE?
EQUIPMENT ENGINEERING UNIT AT S&M
429
TB174 WHAT IS THE SERVICE LIFE OF HOSE?
10 YEARS
430
TB174 ALL HOSE SHALL BE CLEANED AFTER USE. DIRTY HOSE CLEANED WITH CLEAR, COLD WATER. HEAVILY SOILED HOSE CAN BE CLEANED WITH WHAT?
5-10% LIQUID SOAP
431
TB174 WHEN HOSE IS TAKEN OUT OF SERVICE FOR LEAKS, WHERE SHOULD THE HOSE BE TAPED?
AROUND AREA OF LEAK
432
TB174' WHEN TESTING HOSE, SLIGHTLY OPEN GATE AND NOZZLE, RAISE PRESSURE TO WHAT?
45PSI
433
TB174 WHEN TESTING HOSE, RAISE PSI NO GREATER THAN?
15PSI PER SEC
434
TB174 HOW LONG IS HOSE TESTED FOR?
5 MIN
435
TB174 WHILE INSPECTING FOR LEAKS, REMAIN OUTSIDE TESTING AREA. NEVER STAND WHERE?
1) WITHIN 15' IN FRONT OF THE FREE END OF THE HOSE; 2) CLOSER THAN 15' TO EITHER SIDE OF THE HOSE; 3) STRADDLE HOSE IN THE TESTING AREA
436
TB174 WHAT HAPPENS IF A SECTION OF HOSE IS LEAKING OR BURSTS?
IMMEDIATELY STOP TESTING. DRAIN HOSE AND REMOVE DEFECTIVE HOSE
437
TB174 AFTER HOSE HAS BEEN TESTED HOW LONG SHOULD THE ENGINE IDLE BEFORE BEING SHUT DOWN?
5 MIN
438
TB174 HOW DO YOU OBSERVE FOR COUPLING SLIPPAGE?
MARK FULL CIRCUMFERENCE OF HOSE
439
TB174 STATION COMMANDERS SHALL MAKE WHAT ENTRY AFTER COMPLETION OF HOSE TEST?
F2 F129
440
TB174 ALL DOUBLE JACKETED FIREFIGHTING HANDLINES (1"- 2-1/2") ARE TESTED TO WHAT?
400PSI
441
TB174 ALL HOSE OTHER THAN DOUBLE JACKETED FIREFIGHTING LINES ARE TESTED AT WHAT PSI EXCEPT SUPPLY HOSE?
300PSI
442
TB174 4" SUPPLY HOSE IS TESTED AT?
250PSI
443
TB103 200 AND 400 SERIES ENGINES ARE EQUIPPED WITH WHAT FOAM EQUIPMENT?
FOAM NOZZLE JET CONTROLLER
444
TB103 WHAT FOAM EQUIPMENT DO ENGINES, 200 AND 400 SERIES HAVE?
1 1/2" IN LINE FOAM EDUCTOR 1" BUBBLE CUP NOZZLE
445
TB103 CLASS A FOAM REDUCES SURFACE TENSION AND INCREASES THE EFFECTIVENESS OF WATER BY?
3-5 TIMES
446
TB103 CLASS B FOAM SEALS FLAMMABLE VAPORS UNDER THE FOAM. WHAT PERCENTAGE OF THE STREAM FLOW SHOULD LAND ON THE FLAMMABLE LIQUID?
AT LEAST 80%
447
TB103 HOW FAR WILL EFFICIENT FOAM DEVICES THROW FOAM?
NEARLY AS FAR AS WATER
448
TB103 WHAT TYPE OF NOZZLE IS THE HYDRO FOAM NOZZLE?
NON ASPIRATING TYPE
449
TB103 THE HYDRO FOAM SYSTEM ENTRAINS ____AIR INTO THE SYSTEM?
LESS
450
TB103 THE HYDRO FOAM SYSTEM PRODUCES HIGH QUALITY FOAM THAT EXPANDS TO THE OPTIMUM RANGE OF?
3:1 TO 6:1
451
TB103 THE HYDRO FOAM SYSTEM CAN WITHSTAND ATMOSPHERIC WINDS AND ?
THERMAL UPDRAFTS
452
TB103 THE HYDRO FOAM NOZZLE PRODUCES 660 GPM AT WHAT PSI?
100PSI
453
TB103 WHAT IS THE REACH OF THE HYDRO FOAM NOZZLE?
180FT
454
TB103 WHAT PERCENT IS THE FOAM CONCENTRATE PROPORTIONED MIXTURE?
3%
455
TB103 THE HYDRO FOAM CAN BE USED FOR NON FOAM SITUATIONS. WHAT PATTERNS CAN BE USED?
STRAIGHT STREAM AND FULL FOG
456
TB103 SOME ADVANTAGES OF THE HYDRO FOAM NOZZLE ARE THERE ARE NO MOVING PARTS ON THE 2 1/2" INLET FITTING, ALLOWS FULL ENERGY OF WATER POWER TO PRODUCE FOAM AND CAN OPERATE EFFECTIVELY AT LOW NOZZLE PRESSURES AS LOW AS?
75PSI OR LESS
457
TB103 THE JRC USES SMALL AMOUNTS OF WATER, PASSING THROUGH WHAT TYPE OF DEVICE?
HIGH EFFICIENCY VENTURI TYPE
458
TB103 THE JRC OPERATES IN THE SAME WAY AS WHAT DEVICE?
SIPHON EDUCTOR
459
TB103 THE SUCTION (FOAM CONCENTRATE INLET) IS LOCATED ON THE SIDE OF THE JRC AND COMES WITH A STANDARD DRUM KIT. WHAT COMES WITH A STANDARD DRUM KIT?
CLEAR PLASTIC PIGTAIL AND RIGID PVC "STINGER" PIPE
460
TB103 WHAT IS THE MAXIMUM AMOUNT OF 1 1/2" HOSE TO CONNECT THE JRC TO THE HYDRO FOAM NOZZLE?
1000FT
461
TB103 BE SURE TO HAVE A SUPPLY OF FOAM CONCENTRATE READY. EPECT TO USE HOW MUCH GALLONS OF CONCENTRATE PER MINUTE?
20 GAL/MIN WHILE WATER IS FLOWING
462
TB103 WHAT IS THE FL FOR THE JRC APPLIANCE?
50PSI
463
TB103 WHAT IS THE FL FOR LP ASSEMBLY WITH JRC?
40PSI
464
TB103 WHAT ARE THE TWO MANUFACTURERS OF THE 1 1/2" IN LINE FOAM EDUCTOR?
WILLIAMS FIRE AND HAZARD CONTROL (.5-6%) TASK FORCE TIPS (.25-6%)
465
TB103 WHAT PERCENT SETTING IS USED FOR FLAMMABLE LIQUIDS FOR THE INLINE FOAM EDUCTOR?
3%
466
TB103 WHAT PERCENT SETTING IS USED FOR POLAR SOLVENTS WITH THE IN LINE FOAM EDUCTOR?
6%
467
TB103 HOW DO YOU STOP THE FLOW OF THE IN LINE FOAM EDUCTOR?
REMOVE PICK UP TUBE OR ROTATE METERING DEVICE TO "0"
468
TB103 MOVING SELECTOR RING FROM FOAM TO WATER WITHOUT A DECREASE IN PUMP PRESSURE WILL RESULT IN A LARGE INCREASE IN NOZZLE PRESSURE. THROTTLE BACK HOW MUCH BEFORE CHANGING FROM FOAM TO WATER?
10%
469
TB103 THE BUBBLE CUP NOZZLE CAN BE USED AS WHAT TWO TYPES?
CONVENTIONAL AND ASPIRATING
470
TB103 WHILE ASPIRATING, SLIDE THE GRAY SLEEVE PORTION FORWARD. WHEN FULLY EXTENDED WHAT WILL BE VISIBLE AT THE BASE OF THE GRAY SLEEVE?
A WHITE LINE ON THE SHAPER
471
TB103 WHAT PERCENT IS WET FOAM?
0.1-0.3%
472
TB103 WHAT PERCENT IS DRY FOAM?
0.3-0.6%
473
TB103 FOAM APPLICATION RATE OF 0.6-1.0% WILL OFFER MINIMALLY MORE FOAM QUANTITY BUT PROVIDE MORE SURFACTANT IN THE BUBBLE SHELL FOR A LONGER LASTING FOAM BLANKET. IT CLINGS READILY TO VERTICAL SURFACES, MAKES FOAM BARRIERS FOR EXPOSURES AND WET LINES THAT WILL HOLD FOR HOW LONG?
30MIN
474
TB175 HERO WIPES ARE AVAILABLE FROM WHO AND ORDERED THROUGH?
S&M; SRS
475
TB175 WHEN WILL ARSON DETERMINE A FIRE WATCH IS NECESSARY?
IF INSURANCE COMPANY SHOULD INVESTIGATE
476
TB175 WHAT IS THE MINIMUM PPE FOR A FIRE WATCH?
FULL PPE AND SCBA
477
TB 183 THE RS3 HAS A Diesel engine WITH WHAT HP?
37.4
478
TB 183 WHAT ARE THE DIMENSIONS OF THE THERMITE RS3?
L: 115" W: 65.5" H: 65" WEIGHT: 3,630LBS
479
TB 183 THE RS3 HAS AN ELKHART BRASS MONITOR TAHT IS SELF ADJUSTABLE AND FLOWS WHAT GPM?
500-2,500
480
TB 183 WHAT IS THE HORIZONTAL AND VERTICAL REACH OF THE RS3?
HR: 300' VR: 150'
481
TB 183 THE WINCH IS ATTACHED AT THE REAR AND HAS 100' OF 1/4" BRAIDED CABLE STEEL AND IS RATED AT?
8,000LBS
482
TB183 THE OPERATOR CONTROLS HAS HOW MANY JOYSTICKS AND ONBOARD CAMERAS?
2; 4
483
TB 183 WHEN INTRODUCING FOAM, PUMP PRESSURE NEEDS TO BE?
HIGHER IN ORDER TO OPEN CLAPPER VALVES
484
TB 183 THE FRONT PLOW IS USED TO PUSH DEBRIS. IT MOVES UP AND DOWN USING HOW MANY HYDRAULIC ARMS?
2
485
TB 183 RS3 IS REQUESTED THROUGH METRO AND HOUSED WHERE?
FS88
486
TB 183 WHEN SUPPLYING THE RS3 WHAT IS THE PREFERRED WATER SUPPLY?
4" WIH A 2 1/2" GATED WYE
487
TB 183 THE RS3 IS ABLE TO OPERATE IN WATER UP TO WHAT DEPTH?
8"
488
TB 183 THE RS3 IS POWERED BY AN INTERNAL COMBUSTION ENGINE AND UTILIZES WHAT TO OPERATE?
OXYGEN
489
TB 187 THE OASIS HYDRANT ASSIST VALVE WEIGHS?
35LBS
490
TB 187 WHAT PROVIDES CORROSION RESISTANCE TO THE INTERIOR OF THE VALVE?
ALUMINUM HALF BALL VALVE
491
TB 187 THE OHAV IS HYDROSTATICALLY TESTED AT WHAT PSI?
900
492
TB 187 THE OHAV HAS A MAX OPERATING PRESSURE OF WHAT AND WHAT FLOW?
250PSI 2000GPM
493
TB 187 IN THE EVENT OF A PUMP OR OPERATIONAL FAILURE, THE BUILT IN SAFETY VALVE WILL DO WHAT?
THE INTERNAL CLAPPER VALVE WILL AUTOMATICALLY CLOSE AND TRANSFER BACK TO HYDRANT PRESSURE WITHOUT AN INTERRUPTION OF FLOW
494
TB 187 WHAT WILL CAUSE THE CLAPPER VALVE TO OPEN AND CLOSE?
VARIATIONS IN HYDRANT PRESSURE OR PUMP PRESSURE, WHAT EVER IS GREATER
495
TB 187 MEMBER WILL REMOVE HYDRANT SLING AND OHAV FROM THE TAILBOARD AND PROCEED AWAY FROM THE TAILBOARD HOW MANY STEPS?
7
496
TB 187 PRIOR TO VERBALIZING TO "TAKE OFF", HOW MUCH SUFFICIENT SLACK SHOULD BE WRAPED AROUND THE HYDRANT?
10'
497
TB 187 WHEN LAYING A LINE, ENSURE THE HAND CRANK IS TURNED WHICH DIRECTION?
COUNTER CLOCKWISE
498
TB 190 WHAT IS A FIRELINE CONSTRUCTED WITH CHAINSAWS AND HANDTOOLS TO REMOVE THE FUEL SUPPLY BY CLEARING FLAMMABLE MATERIAL AROUND THE FIRE?
HANDLINE
499
TB 190 LAFD TYPE II HANDCREW ARE USED FOR:
CONSTRUCTING LINE ON COLD FLANKS AND FOR OVERHAUL
500
TB 190 ALL ENGINES ARE EQUIPPED WITH WHAT BRUSH TOOLS?
2-PAIRS CHAIN SAW CHAPS 2- REFILLABLE METAL FUEL BOTTLES (BAR OIL/PREMIX) 2-RHINOS 1-PULASKI 1-FIRE SHOVEL
501
TB 190 THE PULASKI IS USED FOR CUTTING BRUSH AND SMALL TREES, GRUBBING AND TRENCHING. ONE SIDE IS SIMILAR TO A SINGLE BIT AXE AND THE OTHER SIDE HAS WHAT TO DIG ROOTS AND CUT TRENCHES?
GRUBBING EDGE
502
TB 190 THE FIRE SHOVEL IS SPECIFICALLY DESIGNED FOR HANDLINE CONSTRUCTION. WHEN SHARPENING, START WHERE?
1 1/2" FROM THE HEEL TO THE TIP OF THE BLADE
503
TB 190 WHAT IS A COMBINATION TOOL OF A HOE AND RAKE, CONSISTING OF A HOE BLADE AND TINES?
MCLEOD
504
TB 190 THE MCLEOD, COMBITOOL AND RHINO ARE SHARPENED AT WHAT ANGLE?
45
505
TB 190 WHAT IS A LONG HANDLED TOOL WITH A MULTI-POSITIONED HEAD TO BE USED AS A SHOVE, PICK AND HOE?
COMBI TOOL
506
TB 190 THE RHINO IS A BENT SHOVEL WITH A ___ BEVELED BLADE?
7"
507
TB 190 SAND ALL SPLINTERED WOOD HANDLES WITH WHAT AND FOLLOW UP WITH?
120 GRIT; A LIGHT COAT OF LINSEED OIL
508
TB 190 WHEN CARRYING HANDTOOLS, STAY HOW FAR APART?
10'
509
TB 190 CONTACT WHO FOR REPAIRS, REPLACEMENT AND DAMAGED HAND TOOLS?
WILDLAND FUELS MANAGEMENT UNIT AT FS88
510
TB 190 A SAWYER IS THE MEMBER UTILIZING THE CHAINSAW. WHO CLEARS THE MATERIAL THE SAWYER CUT?
SWAMPER
511
TB 190 WHEN CONSTRUCTING LINE, ALWAYS START WHERE?
AT A SAFE ANCHOR POINT
512
TB 190 WHO SETS THE PACE FOR THE REST OF THE LINE CONSTRUCTION OPERATION?
SAW TEAM
513
TB 190 THE WIDTH OF THE SAW CUT IS DETERMINED BY THE SAW LEADER AND MAY VARY FROM 4' TO 20' DEPENDING ON?
FUEL HEIGHT; CROWN SPACING; WEATHER; FIRE BEHAVIOR
514
TB 190 ONLY CUT ENOUGH VEGETATION TO CONTROL THE FIRE. THE STEEPER THE SLOPE, THE ____ THE LINE SHOULD BE?
WIDER
515
TB 190 WHAT METHOD OF LINE CONSTRUCTION IS WHERE EACH MEMBER STARTS FROM THE FRONT OF THE LINE AND IMPROVES THE CONDITION OF THE LINE UNTIL IT MEETS THE SPECIFICATIONS BY THE TIME THE LAST TOOL IS ENGAGED? EACH PERSON TAKES A PERCENTAGE OF THE WORK NEEDED TO COMPLETE THE ENTIRE HANDLINE.
SWING N STEP OR ONE LICK
516
TB 190 WHAT METHOD IS WHEN EACH TEAM CUTS A SWATH OR SECTION OF THE HANDLINE, WITH THE LEAD TEAM CUTTING ENOUGH FUEL TO ESTABLISH THE HANDLINE, AND FOLLOWING TEAMS COMPLETE THE HANDLINE TO THE REQUESTED LINE SPECIFICATIONS?
SWATH
517
TB 190 LINE SHOULD BE CUT TO WHAT TO ELIMINATE THE POTENTIAL FOR FIRE TO BURN THROUGH GROUND FUELS?
MINERAL EARTH
518
TB 190 HANDLINE WIDTH IS DEPENDENT ON?
FUEL SIZE FLAME LENGTH SLOPE SPREAD POTENTIAL WEATHER
518
TB 190 WHAT IS AN UNDERSLUNG LINE?
HANDLINE THAT IS CONSTRUCTED ON A SLOPE WITH FIRE ABOVE AND UNBURNED FUEL BELOW
519
TB 190 WHAT ARE BURNT YUCCA STUMPS CALLED?
PINEAPPLES
520
TB 190 WHAT IS REQUIRED WHEN CONSTRUCTING AN UNDERSLUNG LINE TO CATCH ROLLING DEBRIS?
CUP TRENCHING
521
TB 190 WHAT IS COMMONLY USED WHEN FLARE UPS OR SPOT FIRES OCCUR AND IT IS NECESSARY TO RETREAT TO A SAFETY ZONE OR ESCAPE ROUTE?
REVERSE TOOL ORDER
522