site criteria for memorial parks or cemeteries
- periphery of town center, little hazard to life/health
- # of cemeteries to be allowed will be based on needs/death rate in municipality as well as future catchment areas
location of memorial parks/cemeteries
- for cemetery based on CLUP
- if none, CLUP - open space (not within SAFDZ) or agricultural (not prime agri land, not tenanted, not part of CARP, not irrigated)
- if without CLUP - adjacent to existing cemetery, area w/in 100m is neither residential, commercial, industrial, institutional, or area deemed by board as appropriate and aligned with PUD principles
what is PUD
planned unit development
one concept of real estate dev/land dev scheme aiming to optimize use of land through innovative site layout etc
physical suitability of cemeteries
- not in environmentally critical areas (Proclamation no. 2146)
Water table should not exceed ___ below ground surface as certified by NWRB (National Water Resources Board)
4.5 m
site accessibility
must be served by a road with minimum ROW of ____ m
8.00
ratio for saleable area
no fixed ratio
for memorial parks, MINIMUM ___% to be utilized for ground interment to maintain park-like character
50%
burial plot size
ground interment
1 x 2.44 minimum
- 5 minimum depth
- 0 setback for plots fronting ROW (no above ground structure)
- 4 MAX height of structure above ground
burial plot size
tomb
- 6 x 3 minimum
- 3 minimum setback
- 0 minimum setback fronting ROW
burial plot size
mausoleum
4 x 5 minimum
- 5 setback
- 0 setback fronting ROW
minimum dimensions for cinerarium
0.3 x 0.3 x 0.6
burial plot size
columbarium/ossuary
0.3 x 0.3 x 0.6
no plot shall be more than ___ meters away from roadway
60
no plot shall be more than ___ meters away from pathway
30
minimum ROW for major roads
8 m
6m carriageway, 2m sidewalk or 1m easement both sides
minimum ROW for minor roads
- 5m
4. 5m carriageway, rest = sidewalk or easement
cul-de-sac minimum diameter
15m
paving material of roads and pathways + minimum path width
either concrete or asphalt
1m minimum - nonslip
for memorial parks located along national primary and secondary roads, a distance of at least ___ meters from edge of ROW shall be imposed with no burial plot
25
buffer strip from national road can be utilized for:
service road
parking purpose
admin building
other facilities
for memorial parks with <=1ha, main pathwalk should be ___ meters minimum width from main gate and ___ meters width pathwalk network
2, 2
if cemetery abuts street/road, setback should be sufficient to accommodate ___ vehicles simultaneously
10
cemetery perimeter fence max height
3m