Ch.2 Mammo Flashcards

(60 cards)

1
Q

What is the frequency of ACR Acceditation?

A

Every 3years

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The material used for the exit port of the mammography tube is necessary because

A

Regular glass would harden the emerging beam

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The intensity of the X-Ray beam from the cathode side of the tube is generally higher because

Q.3 pg.48

A

The heel effect causes variations in the intensity of the X-ray beam

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The design of the lip of the compression paddle (both height and angle along the chest wall) affects all the following except

Q. 4 pg.48

A

It ensures higher compression of the anterior breast tissue

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The primary goal of compression is to

Q.5 pg 48

A

Allow uniform penetration of structures within the breast

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What features of the high-transmission cellular (HTC) grid allow these grids to maintain equal or less radiation dose to the patient compared with linear grids ?

Q6 pg. 48

A

They have copper as the strips and air as the interspace material

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The grid ratio can vary in modern mammography units. A common grid ratio used is

A

5:1

SN: can be as low as 3:1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The chest wall edge of the compression paddle should be aligned just beyond the chest wall edge of the detector to

Question 8 on Pg 48

A

Avoid projecting the chest wall edge of the paddle on the mammogram

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Which of the following affects focal spot size ?

A

Angle of the anode

SN: the focal spot is the area where electrons strike on the target

SN: effective focal spot is the area projected onto the patient or detector

SN: spatial resolution is related to focal spot size, BUT CHANGES IN SID, OID, and Size of Collimation Field do NOT affect the focal spot size !

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Which of the following is the commonly used focal spot size for routine work in mammography?

A

0.3mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Which of the following mammography quality control test is performed as needed?

A

Repeat analysis

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The general criteria to pass the new American College of Radiology-Digital Mammography (ACR DM) phantom require a minimum of

A

2.0 masses

See question 12 on PG 49
See answer question on PG 56-57

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the compression thickness indicator test?

Q.13 pg 49

A

A check to ensure that the indicated compression thickness is within normal compression

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the name given to the test to determine whether the unit has consistent detector signal-to-noise level for all breast thickness?

A

Visual checklist

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

A technologist test that is performed semiannually is

Q. 15 on pg 49

A

Compression force test

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Repeats are

A

Images that involve unnecessary exposure to the patient

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

To get a meaningful analysis, the repeat analysis needs a patient volume of at least ?

A

250 patients

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Mammography facilities can receive certification from
1. ACR
2 FDA
3. States as Certifiers (SACs)

A

2 or 3 only

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Aluminum filtration is likely to be matched with _____ targets

A

Tungsten

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Which of the following visual checklist tests must be performed before clinical use ?

A

Paddles/ face shield must not be cracked

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

What tool is used to evaluate for artifacts ?

A

Phantom

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

A single binary digit of data, such as “0” or “1” is called a

A

Bit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

In general, higher magnification will require the use of a
Q.23 pg50

A

Smaller focal spot size

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

A grid is not necessary during magnification because
Q.24 pg50

A

The large OID produces the same effect as a grid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
The air gap in magnification allows increase subject contrast by Q.25 pg.50
Reducing scatter
26
If the magnification mammography is performed without using a small focal spot size, the resulting image will be magnified
And blurred
27
At higher magnification factors there is 1. Higher skin dose 2. Increased scatted 3. Decreased source-to-object distance
1&3 only
28
Magnification is beneficial in all of the following situations except Q.28 pg50
Imaging the entire breast in a single exposure
29
Using a small focal spot size is recommended for magnification Question 29 on pg 50
To compensate for the loss of image detail
30
Which of the following is a big disadvantage of magnification?
Increased patient dose
31
If the backup time stops a breast exposure, the technologist can repeat the radiograph by using a
Higher peak kilo voltage setting
32
The type of X-rays created from displacement of K-shell-binding, electrons in the molybdenum atom are called
Characteristic radiation
33
The function of the filter in mammography is to remove Q.33 pg.51
Photon energies higher and lower than the range needed for breast imaging
34
A recommended labeling for the mammographic image that is not required by the Mammography Quality Standards Act (MQSA)
Technical factors
35
Lack of breast compression is most likely to cause Q.35 pg51
Motion unsharpness
36
How long should a facility maintain records of serious complaints?
3years
37
Which of the following focal spot sizes is used in routine imaging ? Q.10 pg49
.3
38
Which of the following systems does not use a grid ?
Any magnification mammography system
39
Aluminum (Al) can be used as the filtration in Q.39 pg.51
Digital breast tomosynthesis tubes with tungsten targets
40
The detector element (DEL) is located in the
Thin-film transistor (TFT)
41
Which of the following statements about detector elements is incorrect See PG 52 for the question 41
The size of the detector element can be controlled by the technologist See PG 69 for detail See PG 41 for the question
42
To allow full coverage of the detector, a tube with a 16-degree anode angle requires a tube tilt of approximately ___ degrees to achieve an effective anode angle of 22 degrees
6 SN: see pg 69 for detail
43
Which of the following monitors is used to interpret the mammograms? Q. 43 pg52
Review monitor See page 70
44
Which of the following is a system that can be used to store 12months or more of image data and can retrieve the data within a few minutes
Redundant array of independent (inexpensive) disk (RAID) See page 70
45
A computer network system that allows images to be viewed at various monitors or transmitted or stored is termed
PACS Picture archiving and communication system
46
The remote transmission of images is
Teleradiology
47
What is the purpose of CAD See Question 47 on pg 52
A method of prereading mammograms See answer to question on 72
48
Which of the following is included in a workflow plan for a technologist Q.48 pg. 52
Retrieving the results of prior examinations for the patient
49
What system is identified as a storage for radiology imaging information
RIS
50
When transmitting mammography images, the compression required is termed Q.50 pg.52
Lossless compressing
51
The device used to convert electronic signal to computer language is called
ADC SN: see pg 73 Question 51
52
Changing the image contrast would mean adjusting the Se question 52 on pg 53
Window width SN: See pg 73
53
In direct digital technology, the x-ray strike ___ in the detector
amorphous selenium
54
What test tool is used to calibrate the brightness of the monitor ?
SMPTE SN: SE PG 74
55
Which of the following is a true statement according to the EQUIP mandated by FDA See question 55 on pg 53
Written documentation is required for the clinical image review of each radiologic technologist (RT) and interpreting physician (IP), and it must be done at least annually See answer explanation on pg 74-75
56
What is the maximum possible score for each test in the ACR phantom
6 See pg 75
57
Synthesized 2D imaging is a See question 57 on pg 53
Two-dimensional (2D) reconstruction of the three-dimensional (3D) image See answer to question on PG 75
58
Computer-aided detection (CAD) is used to See question 58 on PG 53
Analyze or preread the image See answer pg 76
59
What BI-RAD category recommends short-interval (6month) follow up? Question 59 on pg 53
Category 3 See pg 76
60
The patient has a BI-RAD category 5 report This finding indicates
High possibility of malignancy See PG 76