Ch27 medical physics Flashcards
(13 cards)
x ray tube
at cathode, an electric current heats a filament that produces electrons.
electrons are accelerated by pd towards the anode(targeted metal)
when electrons strike the metal, x rays are produced
x ray absorption mechanism
simple scattering
x ray has energy less than work function.
so x ray performs a simple scatter in which it does not lose energy.
x ray absorption mechanism
compton scattering
the incoming x ray has a high energy so it removes the electron
there is still some energy left and a lower energy photon is scattered.
x ray absorption mechanism
pair production
incoming x rat has high energy and interact with the nucleus
an electron-positron pair is produced
they normally annihilate and produce a pair of low energy photons
x ray absorption mechanism
photoelectric effect
x ray with high energy is absorbes
electron gain this energy and escape
electron released with some kinetic energy
x ray characteristics
x rays contrast media
barium and iodine are injected into the patient or digested.
the contrast media absorbs x rays duebto high num of protons.
x ray attenuation is proportional to z^3
contrast media allow outlines of soft tissue
CAT Scan
- x ray tube rotates around the patient.
- a thin fan shaped beam pf x ray is used
- x rays are absorbed differently by different tissues and intensity of x rays is recorded by the detector
- images of slices pf patient are taken
- x ray tube moves along the patient
- computer software produce 3d images
adv and dis of CAT Scan
- x-rays scan is quicker and cheaper than CAT
- CAT can be used to create 3D images
- harmful if exposed for long time
medical tracers
medical tracers are radioactive substances, either injected or digested, used for diagnosis or treatment of patients.
properties of medical tracers
- typically gamma sources.
- half life need to be long to be detected but short so it doesn’t stay in the patient for long time.
- activity must be large to be detected from outside the body
- must be non toxic
examples of medical tracers
technitium 99m
flourine 18
used in pet scan