Chapter 4 -Fire Ground Operations Flashcards

(33 cards)

1
Q

when attaching blind caps to the 6” intakes, it is only necessary to put them on ________.

A

hand tight

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

the hard sleeve connections must be hammered with a _____ to ensure a leak free fit

A

rubber mallet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

from the standpoint of maximum efficiency (volume), it is best to use the 6” intake on the _____side

A

drivers side

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

the end of the hard sleeve assembly shall be submerged at least ____inches

A

18

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

whirlpools can be prevented by placing a _____ at the water surface

A

baffle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

baffles can be improvised from what?

A

wooden door, salvage cover or similar objects

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

when preparing a pump for drafting, the transfer valve should be in the _____position

A

volume

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

if less than _____% of the capacity is being flowed, consider placing the pump in pressure stage after achieving a draft.

A

70%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

one inch of mercury is equivalent to ____ft of lift when not discharging any water

A

1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

fill your tank up from a draft (true/false)

A

false *do not fill tank from draft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

engage primer until draft is achieved, no longer than _____ seconds

A

45

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

the strainer should be kept off the bottom (true/false)

A

true *to prevent grit from entering the pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

hydrant capacity 1500 or > gpm

A

blue

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

hydrant capacity 1000-1499 gpm

A

yellow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

hydrant capacity 500-999 gpm

A

orange

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

hydrant capacity 500 or < gpm

17
Q

hydrant capacity (not tested yet)

18
Q

static reading - residual reading = __________

A

pressure drop

19
Q

pressure drop divided by static pressure =_________

20
Q

static pressure is ___________

A

no water flowing

21
Q

residual pressure is ____________

A

water flowing *250 gpm

22
Q

the pumping apparatus used in this department are rated for capacity at ______psi

23
Q

under the system of pumper classifications, pumping apparatus is rated for 150 psi, which signifies that they are _______

A

class a pumpers

24
Q

pump operators attempts to supply more water than is being taken in via a supply, causing the supply line to collapse. to prevent this from occurring maintain an intake pressure of at least ____ psi

25
full capacity of the pump with a pressure of 150 psi
1250 gpm
26
7/10 capacity of the pump with a pressure of 200 psi
880 gpm
27
1/2 capacity of the pump with a pressure of 250 psi
625 gpm
28
for dual line relay, how many engines would you need for 1600 ft of hose
3 (1 engine at the source and 2 laying out)
29
In dual line relay operations, pump pressures shall be calculated to give a minimum of ____gpm unless otherwise ordered
600 gpm
30
for dual line relay, how many engines would you need for 2400 ft of hose
4 (1 engine at the source and 3 laying out)
31
for heavy hookup utilize the _______or _______ banded hydrant
blue or yellow
32
waterous recommends that the pump be transferred from pressure to volume if the required fire flow is greater than _____% of its rated capacity
70
33
to prevent damage to the clappers that operate when transferring the pump from one stage to the other, the intake and discharge pressures shall be within ____psi of each other
50