Coils Flashcards

(31 cards)

1
Q

Electromagnetic components of RF System maybe provided by outside supplier and assemble by MRI manufacture

A

RF SYSTEM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

2 Coils

A

SHIM COILS -MAKE MAGNETIC FIELD HOMOGENEOUS
RECEIVER COILS-DETECT THE RETERNING RADIOSIGNAL ARE ‘ANTENNA’ OF THE MRI SYSTEM THE BROADCAST

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

4 TYPES OF COILS

A

SURFACE COILS, PAIRED SADDLE COIL, HELMHORTZ PAIR COIL, BIRDCAGE COIL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

use are the simply loop of wire either circular or RECTANGULAR

A

Surface coil

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
  • Provide better homogeneity of RF in area of interest
A

PAIRED SADDLE COIL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

consis of two circular coils parallel

A

HELMHORTZ PAIR COILS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q
  • Transceiver coil for imaging of the head
A

BIRD CAGE COIL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What are the Power supply of MRI

A

2.4Kw, 5% voltage ripple, 1.5 Tesla commonly used

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Use ALUMINUM, FORM OF SHEILD FARADAY CAGE, PRETECTION THE VERY WEAK RF SIGNAL

A

FARADAY CAGE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Is used in MRI to describe the relative contribution detected signal of background noise

A

SNR/SIGNAL NOISE RATIO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

IF SNR WILL INCREASE
FACTOR AFFECTING SNR

A

BO,T1,T2,TE,TR,FOV,nex,matrix size, RF BANDWIDTH, PIXEL SIZE, SLICE THICKNESS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

6 INCREASE IN FACTORS AFFECTING SNR

A

BO,TR,T2,FOV,RF BANDWIDTH,PIXEL SIZE, SICE THICKNESS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

4DECREASE IN FACTORS AFFECTING SNR

A

T1,TE,NEX,MATRIX SIZE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Types of IF ALL PARAMETERS ARE CONSTANT/bandwidth

A

RF COIL,RF BANDWIDTH,THE RECEIVER (ACQUISITION)BANDWIDTH,THE TRANSMIT BANDWIDTH,PULSE SEQUENCE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

IF ALL PARAMETERS ARE CONSTANT

  • smaller sensitive volume of coil,local coil or better amd selected SLICE PLANE
A

RF COIL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q
  • refers the frequencies associated either with RF excitation
17
Q

Range of frequencies accepted by the receiver to sample MR signal

A

THE RECEIVER (ACQUISITION)BANDWIDTH

18
Q

Slice selection in pulse sequence, slice thickness, lowering the PULSE

A

THE TRANSMIT BANDWIDTH

19
Q
  • Acquire images with different tissue contrast mechanism
A

PULSE SEQUENCE

20
Q
  • MRI uses technology is called?
A

Pulse sequence

21
Q

diffusion movement of molecules due to random motion

A

Diffusion weighted imaging(DWI)-

22
Q

How many hours in DWI/Diffusion weighted imaging in prior scan

A

72HOURS prior scan

23
Q

What will use in DWI?

A

used CVA/ CARDIOVASCULAR ACCIDENT and CNS/CENTRAL NERVOUS SYSTEM

24
Q

In what signal diffusion values in DWI

25
WHAT IS THE DWI REMAINS SENSITIVE ?
T1AND T2 RELAXATION
26
Most widely used start in 90pulse and ends of 180 degree pulse
SPIN ECHO
27
Refocus the spin gradient echo are more susceptible to blood flow 90° in additional TRand TE, Aka reverse the polarity of gradient
GRADIENT ECHO
28
How many flip angles of GRADIENT ECHO
LESS THAN 90°
29
2FAST PULSE SEQUENCE
Fast gradient echo(FGRE),FAST SPIN ECHO (FSE)
30
For turbulent blood flow
Fast gradient echo(FGRE)
31
is quicker because it is cover wide range of tissue used start in 90pulse and ends of 180 degree pulse
FAST SPIN ECHO(FSE)