cold water Flashcards

(41 cards)

1
Q

Which British Standard makes recommendation on the minimum of cold water storage cistern for a particular property?

A

Bs6700

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The water flow rate from a cold water tap is 8 litres per minute, what is the flow rate measured in litres per second?

A

0.13 l/s

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The quantity of fittings delivered to site by a plumbers merchant will be shown in a

A

Delivery note

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Which type of cold water system is normally used in a dwelling which has a high incoming water pressure?

A

e)Direct.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The Water Regulations require that the warning pipe in a small cold water storage cistern must be

A

Sized to be able to cope with the flow if water if the inlet valve fails

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the required soundness test pressure pipe which has a maximum operating pressure of 4 bar? for a copper cold water supply

A

6bar

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

8 What is the minimum recommended clip spacing distance for a 15 mm vertical copper pipe?

A

1800mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Which one of the following components must be sited immediately after the supply stop valve on entry to a dwelling?

A

Drain valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Before leaving site, open ended pipework connected to a live but isolated cold water supply must be

A

sealed with watertight stop ends

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Which one of the following is a key feature of a direct cold water system?

A

Cold water outlets are taken from the rising supply pipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Which one of the following types of device is suitable to provide backflow protection for a pair of pillar taps to a kitchen sink?

A

AUK3 air gap.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the minimum recommended distance between the top of a cold water storage cistern and an adjacent sloping roof?

A

350mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What should be carried out before undertaking a soundness test on a completed cold water system?

A

Visual inspection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the minimum recommended distance for an insulated cold water service pipe entering a dwelling through a suspended timber floor? The distributing

A

No recommended

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The Water Regulations identifies that it is preferable to connect a cold water distributing pipe into a cistern at which one of the following locations? In the

A

base of the cistern

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What name is given to the spacer used when fixing a pillar tap to a stainless steel sink?

A

Top hat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Which one of the following will most likely need to be informed before turning off the cold water supply to a rented house in order to carry out maintenance work?

18
Q

When permanently disconnecting the cold water supply, Water Regulations (Byelaws) requires

A

create any dead legs in the pipework system

19
Q

What type of plumbing fitting is used to make a watertight seal to an open pipe end?

20
Q

What type of plumbing fitting can be used to control the water pressure supplied to a shower?

A

Pressure reducing valve

21
Q

A maintenance programme in which float operated valves are re-washered annually regardless of whether the valve is defective is described as

A

planned preventative maintenane

22
Q

Which one of the following will cause the minimum of disruption when isolating the entire cold water supply to undertake a maintenance job lasting up to 4 hours in a food production factory?

A

Doing the job outside normal working hours

23
Q

Which one of the following is a replacement part for a pillar tap?

A

Rubber washer

24
Q

There is no water flow at the cold water outlets in a property. What is the most likely cause of a blockage

A

Fully blocked line strainer

25
defective double check valve sited inside the property that is supplying an hose union bib tap can be repaired by
replacing the hose union tap with one that contains a double check valve
26
replacing the hose union tap with one that contains a double check valve
replacing the hose union tap with one that contains a double check valve
27
A plumber is most likely to be required to complete a maintenance record for a cold water system when working in which one of the following types of property?
Food production factory
28
Food production factory
Food production factory
29
The re-washering of a tap fails to prevent dripping at its outlet, which one of the following may overcome the problem?
Re-cutting the worn tap seat
30
Which of the following is considered a reliable underground water source?
Artesian wells
31
What makes water "plumbo-solvent"?
Soft water with added CO2
32
What is the primary purpose of flocculation in water treatment?
To remove colour and turbidity
33
Which system supplies water directly to all outlets without storage?
Direct cold water system
34
What level of chlorine is typically added during disinfection?
Less than 1 mg/L
35
35
35
35
35
35
35