cold water Flashcards
(41 cards)
Which British Standard makes recommendation on the minimum of cold water storage cistern for a particular property?
Bs6700
The water flow rate from a cold water tap is 8 litres per minute, what is the flow rate measured in litres per second?
0.13 l/s
The quantity of fittings delivered to site by a plumbers merchant will be shown in a
Delivery note
Which type of cold water system is normally used in a dwelling which has a high incoming water pressure?
e)Direct.
The Water Regulations require that the warning pipe in a small cold water storage cistern must be
Sized to be able to cope with the flow if water if the inlet valve fails
What is the required soundness test pressure pipe which has a maximum operating pressure of 4 bar? for a copper cold water supply
6bar
8 What is the minimum recommended clip spacing distance for a 15 mm vertical copper pipe?
1800mm
Which one of the following components must be sited immediately after the supply stop valve on entry to a dwelling?
Drain valve
Before leaving site, open ended pipework connected to a live but isolated cold water supply must be
sealed with watertight stop ends
Which one of the following is a key feature of a direct cold water system?
Cold water outlets are taken from the rising supply pipe
Which one of the following types of device is suitable to provide backflow protection for a pair of pillar taps to a kitchen sink?
AUK3 air gap.
What is the minimum recommended distance between the top of a cold water storage cistern and an adjacent sloping roof?
350mm
What should be carried out before undertaking a soundness test on a completed cold water system?
Visual inspection
What is the minimum recommended distance for an insulated cold water service pipe entering a dwelling through a suspended timber floor? The distributing
No recommended
The Water Regulations identifies that it is preferable to connect a cold water distributing pipe into a cistern at which one of the following locations? In the
base of the cistern
What name is given to the spacer used when fixing a pillar tap to a stainless steel sink?
Top hat
Which one of the following will most likely need to be informed before turning off the cold water supply to a rented house in order to carry out maintenance work?
Tenant
When permanently disconnecting the cold water supply, Water Regulations (Byelaws) requires
create any dead legs in the pipework system
What type of plumbing fitting is used to make a watertight seal to an open pipe end?
Stop-end.
What type of plumbing fitting can be used to control the water pressure supplied to a shower?
Pressure reducing valve
A maintenance programme in which float operated valves are re-washered annually regardless of whether the valve is defective is described as
planned preventative maintenane
Which one of the following will cause the minimum of disruption when isolating the entire cold water supply to undertake a maintenance job lasting up to 4 hours in a food production factory?
Doing the job outside normal working hours
Which one of the following is a replacement part for a pillar tap?
Rubber washer
There is no water flow at the cold water outlets in a property. What is the most likely cause of a blockage
Fully blocked line strainer