Controls- Part B Flashcards

(37 cards)

1
Q

The three primary reasons for sending and measuring variables are to

A

Indicate record and control

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The fore main typed of measured variables are

A

Liquid level temp pressure and flow rate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

To protect thermometer and other sencing bulbs from high external pressure and possible damage,_______ are installed in pressure vessels and pipe

A

Thermoweld

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The_________ ________ ______ produces a longer scale of measurement then other types so a more accurate reading can be take

A

Inclined tube manometer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

_______or _______ to be applied to the gauge ID connected to the housing that encloses the diaphragm

A

Pressure or vacuum

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

As a result, the _______ rises and falls with the liquid level and this movement can be used to operate a control valve

A

Float

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

An _______ is the most common form of restriction used to measure flow

A

Orifice plate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The term ________ ________ is explained as the point where the area is at a minimum size; therefore the fluid is at its highest Velocity and lowest pressure

A

Vena contracta

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

______ ______ sense impact and static pressure at the same instant.

A

Pito tube

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

On a small system, a______ ______ ______ located in the compressor room supplies reduced pressure to the entire control system.

A

Pressure reducing station

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The _______ _____ filter is to prevent dust or other airborne contaminants from entering the intake valves of the compressor.

A

Air filter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The compressor oil must be the type recommended by the _______ manufacturer to maintain the life of the compressor and the warranty

A

Manufacturer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Limiting _________ in compressed air piping is of the utmost importance

A

Moisture

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Another type of dryer involves the use of ______ or chemical to remove moisture from the control air

A

Desiccant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The______ ______ is located in the piping between the compressor and pressure- reducing valve

A

Moisture condenser

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The _______ _______ has been decreased in the system thereby reducing the amount of water deposited throughout the system

A

Air temperature

17
Q

Precautions should be made when working moving equipment;________ and _____ procedures should be followed

18
Q

When troubleshooting the sensing and measuring variables, you would be primarily concerned with.

A

Primary element

19
Q

A thermometer is really designed to measure

A

Molecular movement

20
Q

When a pressure gauge is located on the process piping, it is classified as

A

Integral mounted

21
Q

The sending element normally used in a pressure gauge is

22
Q

The thermoelectric promoter temperature uses.

A

DC millivolts

23
Q

Floats can control, indicate, or record events; this liquid level device is based on the laws of

A

Buoyancy laws

24
Q

The only type of flow measuring device that accurately measures volume is the

A

Positive displacement type

25
When installing an orifice plate between a pair of orifice flanges, the stamped face is normally installed.
Upstream of flow
26
Which flow sensing device will handle more flow with less pressure drop
Pilot tube
27
The type of water this is mainly used ad an indicating device is the
Rota meter
28
Moisture is introduced into the pneumatic control system from the
Intake filter
29
The air compressor is controlled by a
Pressure switch
30
The aftercooler is located
Before the receiver
31
Lubrication should remain in the
Compressor
32
The type of air drying technique that uses a cooling tower is
Moisture condenser
33
The building type that would require the most ridged HVAC standards is an
Hospital
34
The primary noises transmitted from the compressor are caused by.
Vibration
35
They type of pipe or tubing found on a large pneumatic instrumentation system is
Galvanized pipe
36
Before filling and testing a system that contains float type meters. You should
Install plugs
37
Each control balv4 should have a
ID tag