Crime Scene Manual Flashcards

(188 cards)

1
Q

This technique is used to test stains for the presence of proteins found in blood.

A

Hemastix - Presumptive Test for Blood

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

When using Hemastix, a positive response indicates the suspected stain is ______________________________.

A

possibly comprised of or contains blood

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Hemastix ____________________ distinguish human blood from the blood of animals.

A

cannot

False positive results are possible.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When using Hemastix _____________ results are possible.

A

“false positive”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Hemastix has a shelf life of ________________.

A

Approximately One year

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

While using Hemastix beyond the expiration date will not produce “______________” results, it may produce “______________” results.

A

will not produce “false positive” results

may produce “false negative” results

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

As a general practice, Hemastix should be __________ or used only for training beyond the date of expiration.

A

discarded

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Before being used to perform test(s) upon questioned stains, the Hemastix reagent should be tested _______________________.

A

against a known human blood standard

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

A control test should be conducted whenever test strip(s) from a new container are used _______________________________ or if ______________________________________________.

A

for the first time or if more than 24 hours has elapsed since a control test was performed for a previously used container.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Testing with Hemastix will likely __________________ the appearance of the stain being tested.

A

change

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

A stain should be photographed prior to testing if its _______________ may be relevant to the investigation.

A

characteristics

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Hemastix is very sensitive; therefore, it is only necessary to transfer _______ of the stain onto the swab.

A

a trace

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

When testing with Hemastix, a positive result is indicated by the immediate appearance of a __________ color on the pad.

A

blue-green

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When using Hemastix, if the color change is _____________ (within 1-2 seconds), the result is negative.

A

not immediate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

If a Hemastix test result is not “immediate” (1-2 seconds) then there is not a _______________.

A

positive result

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The pale yellow pads at the ends of the strips ore impregnated with the chemical compound ___________________, which is a blood reagent commonly used in liquid form to perform presumptive tests at crime scenes.

A

tetramethylbenzadine

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

The chemical components of the Hemastix ________________ with DNA analysis.

A

do not interfere

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

The two techniques used to test stains for the presence of the acid phosphatase enzyme present in human semen utilized by the Texas Rangers are the _____ ______ _____ _______ and the _________ _________.

A

Peavy Seminal Fluid Dischap - Presumptive Test for Semen

and

Arrowhead Forensics

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

When using Peavy Seminal Fluid Dischap, a ________________ response indicated the probable presence of semen.

A

positive (purple color)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

When using Peavy Seminal Fluid Dischap the color change should occur within a few seconds (__________), color change may not be immediate.

A

30 seconds

any color change after 30 seconds should be disregarded

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

When using Arrowhead Forensics, a ________________ response indicated the probable presence of semen.

A

deep purple

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

The acid phosphatase reagent ampoule _______________ be applied directly to the suspected semen stain.

A

should not be

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

The acid phosphatase testing will __________ change the appearance of the stain being tested.

A

likely

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

When using either the Peavy Seminal Fluid Dischap or the Arrowhead Forensics, a stain should be _____________ prior to testing if its characteristics may be relevant to the investigation.

A

photographed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
The ____________________ or _______ test is the test utilized in the DPS Crime Laboratory for the detection of semen.
acid phosphatase or "AP"
26
Since the acid phosphatase enzyme is present in ___________, ________________ need not be present for a positive reaction.
semen spermatozoa
27
This chemical reagent is used to locate latent traces of blood on both porous and non-porous surfaces.
Bluestar
28
Bluestar should be used in a ____ room.
darkened
29
When using Bluestar outdoors, ______________.
wait for night
30
Bluestar should be used to _______________ and ______________ post-offense cleaning of a bloodstained area rather than as purely a presumptive test.
demonstrate and photograph
31
When spraying Bluestar, apply a _________ of the mixture from a distance of about two feet.
fine mist
32
_____________ Bluestar will not increase the effectiveness of the mixture.
Over-spraying
33
To photograph a luminescent response with Bluestar, one should use ____ ________ ____ ________ photography.
Bulb Extended Time
34
When using Bluestar a _______________ response is presumptive positive for the presence of blood.
luminescent
35
The use of Bluestar _________________ the testing of evidence for DNA.
will not prohibit
36
Bluestar has a shelf life of _____ years.
three
37
Once Bluestar is mixed, it is best used within _____ of production.
three hours
38
Bluestar __________ be stored after production.
should not
39
Packaging of bloodstained clothing should be done in order to __________________________________.
to avoid or prevent transfer or alteration
40
Bloody clothing may be placed on a sterile clothes hanger and _______ __ _____ with all seams taped.
wrapped in paper
41
If blood soaks through a packaged item of evidence you should__________________________?
not unpackage the item Remove the evidence tag, repackage the item, then place the evidence tag on the outside of the new paper.
42
The technique used to collect a portion of a visible biological stain (blood, semen, saliva, etc.) for subsequent crime laboratory DNA analysis:
Discriminate collection of a biological stain.
43
The technique used to collect a portion of a visible biological stain (blood, semen, saliva, etc) for subsequent crime laboratory (DNA) analysis is:
dampen an individually packaged sterile swab with sterile water, then vigorously scour the portion of the stain to be collected. Return the swab to its wrapper with the swab end near the opening.
44
When swabbing a biological stain, one should attempt to obtain a _____________ of the biological material on one portion of the swab rather than allowing _________ of the stain throughout the swab.
concentration / diffusion
45
The technique used to attempt to collect latent traces of biological material (blood, semen, saliva, etc.) from surfaces upon which its existence is suspected but not apparent or visible.
Indiscriminate collection of biological material. Collection method the same as discriminate collection.
46
For pourus surfaces with visible blood stains, it is always best to ___ _ ______ containing the stain when it is not practical or possible to collect the entire item.
cut a swatch
47
This technique is used to enhance faint pattern transfers in blood on absorbent surfaces.
Tri-Dri Leucocrystal Violet
48
Leuccrystal Violet (LCV) can create _______________ when applied to bloody pattern transfers which can cause degradation of pattern detail, especially in friction ridges.
bubbles
49
LCV is preferred for ______________________________ (e.g., carpeting, clothing, paper, etc.).
porous or absorbent surfaces
50
LCV produces a _____________________ colored reaction when it comes into contact with blood. The background surface color should be considered when deciding to whether to apply LCV.
violet or purple
51
LCV has a __________________ shelf life. Once mixed, the LCV solution has a ____________ shelf life.
indefinite | 30 day
52
A Tri-Dri Lecocrystal Violet Kit is mixed with one _____ ______ __ ________ ________.
one 16 oz. bottle of hydrogen peroxide
53
All bloodstains must be _______________ prior to the application of LCV or Amido Black.
dried
54
Cyanoacrylate fuming may be __________________ to the LCV and the Amido Black process.
detrimental
55
The ______ detail can normally be achieved by applying the LCV to the faintest patterns.
finest
56
When applying LCV for footwear patterns, spraying ___________ the last visible pattern will normally produce the best results.
just beyond
57
If the pattern is comprised of blood, the LCV solution will react within __________ by changing the stain a violet color.
30 seconds
58
This technique is used to enhance faint pattern transfers in blood on non-porous surfaces.
Amido Black
59
Amido Black is preferred over Leucocrystal Violet for the ___________ and ___________ of bloody friction ridge detail.
enhancement and development
60
Caution must be exercised when applying the methanol-based formula to ___________________ surfaces because it may destroy friction ridges and/or other pattern transfers as well as the surface beneath them.
painted or lacquered
61
Amido Black should not be applied to ______ ________ because it may stain the surface and prevent visualization of any enhanced bloodstain patterns.
porous surfaces
62
_________________ is preferred over _________________ for the enhancement and development of bloody friction ridges.
Amido Black preferred over Leucocrystal Violet
63
Amido Black produces a ______ or ____ ____ stain when it comes into contact with blood.
indigo or dark blue
64
Amido Black has two forms of solutions, ______________ and ___________.
methanol based and water based
65
Amido Black has an __________ shelf life.
indefinite
66
Amido Black should be stored at ________________.
room temperature
67
Amido Black __________ be stored in vehicles for extended periods.
should not
68
The Amido Black water-based formula is _______ in sensitivity and color intensity to that of the methanol-based formula.
similar
69
If both LCV and Amido Black are contemplated, ___________ must be sequenced first.
LCV
70
When using the methanol based Amido Black solution leave the developer solution on the surface for approximately __________ to ________.
30 seconds to 1 minute
71
When using the water based Amido Black solution leave the developer solution on the surface for approximately __________ to ________.
3 to 5 minutes
72
A small fan or pressurized air canister may be used to ______ the solutions away from the developed patter.
"push"
73
Once a pattern has been enhanced with Amido Black, it may then be photographed using ______________________.
Comparison Photography
74
When burning photos taken with the Nikon D7100 / D7000 camera to a disk, two DVD-R should be created. The first DVD-R created will be labeled ___________________ and should be handled as a piece of evidence. The second DVD-R will be labeled _______________ and should be kept in the investigative file.
1st disk - "Original/Archive Disk" 2nd disk - "Working Disk"
75
This technique is used to photograph subjects under reduced or limited lighting conditions whenever an exposure under existing light is preferred over the use of the flash and when the proper exposure can only be achieved with a shutter speed that renders hand-held operation of the camera impractical due to camera movement.
Metered Extended Time Exposure
76
The Metered Extended Time Exposure technique involves slower shutter speeds that make camera movement and subject movement a paramount concern, the camera and subject should be rendered ____________ during the exposure period. The remote shutter release cable or time delay function must be used. Using hands/fingers to activate the shutter release usually results in a blurred image.
immobile
77
This technique is preferred for exposures made under lighting conditions that are too dark for metering or when the desired exposure time exceeds 30 seconds.
Bulb Extended Time Exposure
78
The Bulb Extended Time Exposure technique involves exposure times in excess of 30 seconds; therefore, the camera must be immobilized on a tripod or other similar device during exposure periods. _________ operation is not an option.
Hand-held
79
These procedures are used to obtain macro photographs of items of evidence that are to be used for comparison with known standards.
Comparison Photography
80
Due to the shallow depth of field associated with macro photography, use the tripod and remote shutter release cable (or time delay shutter release function) to immobilize the camera to prevent ________ of fine details.
blurring
81
The objective of comparison photography is to utilize _____ and/or _______ to obtain a sharp image with the greatest possible contrast between the subject and surrounding surfaces.
light and/or shadows
82
Oblique or angled lighting is often employed when using comparison photography to produce ____________ in order to achieve this effect, especially when photographing impressions, tool marks, engravings, etc.
fine shadows
83
This technique is used to obtain photographs of luminescent chemical reactions associated with reagents such as luminol and BlueStar.
Luminescent Reagent Photography
84
Due to the __________ nature of luminescent chemical reactions, the "faster" 50mm w/f1.8 aperture lens may be the preferred lens to use for this technique.
transient
85
This technique is used to obtain illuminated images of extremely dark areas that, due to their size, cannot be effectively illuminated with a single function of the flash.
Painting with Light
86
This technique is used to obtain images of laser beams to illustrate bullet path(s) convergence/origin point(s) for bloodstain patterns, and/or any circumstance where photography of a laser beam is desirable.
Photography of Laser Beam
87
This technique is used to photograph subjects under reduced or limited lighting conditions whenever the introduction of artificial light from the flash unit is preferred over existing light.
General Flash Photography
88
This technique is used to photograph subject areas by introducing artificial (flash) onto a dark foreground while using metered time exposure to properly expose lighted background areas. It is referred to __________________ because the flash is activated when the shutter is first opened (typical) or just before the shutter is closed during the exposure interval. This technique is most effective in large areas (usually at night) where the lighted background is too far away to be influenced by the flash.
Curtain Flash Photography
89
This technique is used to photograph subjects that fluoresce when illuminated with a forensic light source (e.g. dry semen stains, florescent fingerprint powders, certain fibers, etc.).
Fluorescent Photography
90
Fluorescent Photography technique involves slower shutter speeds that make camera movement and subject movement a paramount concern, the camera and subject should be rendered ____________ during the exposure period. The remote shutter release cable or time delay function must be used. Using hands/fingers to activate the shutter release usually results in a blurred image.
immobile
91
When using Fluorescent Photography, a forensic light source is used to illuminate the subject at a particular _________ so that the fluorescent response may be visualized and photographed.
bandwidth
92
TrackStone casting compound is used to create ___________________ casts of impression evidence such as footwear and tire tread impressions found in materials such as dirt, mud, etc.
three-dimensional
93
Trackstone casting compound is a __________________ that hardens when exposed to humidity.
very fine powder
94
TrackStone begins to set __ _____ as it is mixed with water.
as soon
95
TrackStone should be applied to the impression as soon as the ________ ___________ is achieved.
desired consistency
96
Efforts to obtain casts of impression evidence are not always successful; therefore, _____________________ should be made of any impressions before casting is attempted.
photographs
97
Loose debris that has obviously accumulated in the impression since it was formed can be _______________________.
removed with tweezers
98
Debris which is ____________________ in the impression should be left in place.
imbedded
99
Impressions found in loose aggregate (e.g., sand) should be set with an ______________ fixative prior to casting.
aerosol spray
100
If necessary or desirable, place the _______________ around the impression to contain the casting compound, especially on sloped surfaces.
casting frame
101
Never _______________ the compound into the impression.
simply pour
102
Pour the Trackstone compound from a height near the surface onto an area ____________ the edge of the impression so that the compound will spill over the edge and slowly fill the impression.
just outside
103
Use a _______ to interrupt the fall of the Trackstone compound and direct the flow of the compound into the impression.
baffle (e.g., stir stick, piece of cardboard)
104
When using Trackstone to cast impressions in snow, __________ should be substituted for some of the water to create slush.
snow
105
When casting impressions completely submerged in water, the impression should be isolated with a casting frame or other form so that the frame or form is above water level.
True
106
Dry TrackStone powder should be added to the submerged impression until the water is displaced and the desired consistency is achieved.
True
107
In wet conditions TrackStone should be allowed to dry for ________.
one hour
108
A good rule of thumb for allowing the Trackstone cast to set is _____________________.
20 to 30 minutes
109
The Trackstone cast will set _______ in hot weather and ___________ in cold weather.
faster in hot weather and take longer in cold weather
110
Thick mixtures of Trackstone set ________ while thin mixtures __________.
quicker take longer
111
The top of the Trackstone cast should be appropriately marked with a permanent marker immediately after the curing process with at a minimum of _____, ______, __________, and _____________. It should also be marked with an arrow indicating north.
time, date, evidence number, and investigators initials
112
Any casting compound similar to TrackStone such as _________________ may be used to obtain casts of impression evidence. However, _________________ is not recommended.
dental stone Plaster of Paris
113
Adhesive materials (wide fingerprint tape, contact paper, etc) are used to lift larger pattern transfers (e.g., _______________, ________________________, etc.) that have been developed with fingerprint powder on relatively smooth surfaces.
footwear patterns, plantar friction ridge detail
114
Powder development is most effective for patterns that contain __________________ or ______________________.
oily materials or moisture
115
Powder development ____________ normally be used to collect pattern transfers in dust.
should not
116
Black gelatin lifter should be used for ________ __ ____.
patterns in dust
117
________________________ are used to lift pattern transfers (especially footwear patterns) that have been deposited in dust or developed with fingerprint powder.
Gelatin lifters
118
Generally, _____________________ colored gelatin lifters are used to lift patterns developed with fingerprint powder while _____________ colored gelatin lifters are used to lift those found in dust.
white colored for fingerprint powder black colored for dust
119
Since a larger lifting medium is being used to lift footwear patterns, plantar friction ridge detail, etc., extra care must be employed to prevent the development of ______________ between the lifting medium and the surface.
air pockets
120
In some cases, it may be desirable to create a ______________ in air pockets that do develop so as to insure the adhesive makes contact with all detail in the pattern.
pin hole
121
Gelatin lifters are subject to degradation from ____________________.
high temperatures and humidity
122
Gelatin lifters may be routinely carried in the trunks of automobiles but should not be normally carried in the _____________________, especially during summer months.
passenger compartments
123
Gelatin lifters may be routinely carried in the trunks of automobiles but should not be normally carried in the _____________________, especially during summer months.
passenger compartments
124
To prevent the effects of humidity, the _________________ packaging should not be opened until the lifters are to be used.
foil packaging
125
Photographs made of patterns lifted with gelatin lifters are the ___________________ of the patterns as they were on the original surface. When such an image is submitted to the crime laboratory, this condition should be noted so that the image may be reversed when the final image is rendered for comparison analysis.
reverse image
126
_______________ is used to make high resolution casts of various types of pattern transfer and impression evidence.
Mikrosil
127
Mikrosil can be used to make high resolution casts of such evidence as ______________, ____________, and other ____________________.
tool marks firearms marks other small impressions
128
Mikrosil is also effective in lifting fingerprints developed with powder from ___________ or _____________ surfaces.
rough textured
129
Mikrosil begins to set as soon as ______________ are mixed. Therefore, it should be applied to the impression or surface immediately thereafter.
the components
130
Mikrosil is available in four (4) colors: ______________________. Each color provides unique contrast for various applications.
white, gray, black, and brown
131
White and black Mikrosil are preferred for lifting developed fingerprints from __________________________.
irregular surfaces
132
Brown and gray Mikrosil are preferred by ________________ and _________________ examiners for the contrast provided for microscopic comparison examinations.
tool mark and firearms examiners
133
A Mikrosil Kit consists of ___________ separate compounds that must be mixed prior to use.
two Tube of Mikrosil Tube of hardener
134
The two tubes of Mikrosil should be blended together for _______ seconds.
30 to 60
135
The Mikrosil compound needs to set for ____ to _____ minutes in if the temperature is above 68 degrees. The material will need to set for ________ longer in colder temperatures or thick applications.
five to eight minutes fifteen minutes
136
____________________ or _____________________ can be used to develop sebaceous (oily) latent friction ridges on various surfaces.
Standard fingerprint powder or magnetic fingerprint powder
137
Powder development is an instinctive process; however, care must be taken to avoid _______________ and/or ___________ of the ridge detail.
overdevelopment and/or destruction
138
If possible, prints should be ___________ throughout the development process and prior to any attempt to lift them.
photographed using comparison photography
139
Silver/grey powder may be used on __________________ surfaces. However, plain black powder is preferred.
dull black
140
Florescent powder development may be preferable for ________________________ surfaces.
multi-colored
141
Fluorescent powder should be used _______________ than standard fingerprint powder.
more sparingly
142
A _____________________ must be used in concert with the development process of fluorescent powder to insure proper development.
forensic light source
143
If practical, the object containing the latent prints should be treated with ________________________ prior to powder development.
cyanoacrylate (Super Glue)
144
Trace elements that have been visually identified are collected discriminately using a ____________, ______________, ______________, or ________________.
gloved hand, sterile tweezers, adhesives, or other methods
145
If it is necessary to test a suspected bullet defect in an immovable object for the presence of both lead and copper, the _______________ test must be sequenced first.
copper
146
__________________________ are utilized to indiscriminately process the hands of persons suspected to have fired, handled, or been in proximity to a firearm when it was discharged.
Adhesive stub type gunshot residue (GSR) evidence collection kits
147
Laboratory examinations of the stub type GSR kits are conducted using the __________________________ or ___________________________.
scanning electron microscope (SEM) or Energy Dispersive Spectrometer (EDS)
148
GSR stub lifts collected more than ______________ following the event will not normally be analyzed by crime laboratory examiners.
4 hours
149
GSR stub lifts collected from gunshot victims (including suspected suicide victims) will _______________ be analyzed by crime laboratory examiners.
not normally
150
The 2-stub kit may be submitted to the DPS Crime Laboratory.
True
151
There is no practical concern that the use of a 2-stub kit would cause a stub to become "__________" before GSR particles could be collected.
overloaded
152
The DPS Crime Laboratory will not report conclusions as to where on the hand the GSR was detected (back or palm).
True
153
An __________________ is utilized to collect gunshot residue from immovable objects/surfaces.
acetic acid solution
154
________________________ is utilized to determine and demonstrate bullet flight paths for shooting scene reconstruction.
Laser trajectory kit
155
Bodily fluids (especially dry semen stains) are known to emit a fluorescent response when "_____________" with UV, violet, or blue wavelengths.
excited
156
____________ and other types of _______________ may also have fluorescent properties when excited with various wavelengths and viewed through the appropriate barrier filter.
Fibers and other types of trace evidence
157
Typically, prints are _____________ with fingerprint tape and placed onto a backing card after they have been developed and photographed.
lifted
158
This technique is used to develop and preserve latent friction ridge detail on non-porous items that are small enough to be placed into a fuming chamber using the HotShot.
Chambered Cyanoacrylate Fuming
159
Ideally, fuming should be accomplished before ______________ to stabilize and preserve the prints.
packaging
160
______________ are applied to develop latent fingerprints primarily on porous surfaces.
Iodine fumes
161
Iodine fumes are absorbed by _________________ residue in latent fingerprints to render the prints visible.
fatty or oily
162
Iodine fuming __________________ interfere with any other fingerprint processing technique.
will not
163
____________________ is primarily used to develop latent prints on multicolored surfaces for visualization and photography with a forensic light source.
Fluorescent fingerprint powder
164
Magnetic fingerprint powder is used to develop ________________ latent friction ridges on various surfaces. Typically, prints are lifted with fingerprint tape and placed onto a backing card after they have been developed and photographed.
sebaceous (oily)
165
Chemical enhancement techniques (i.e., Leucrocrystal Violet and/or Amido Black) are used to develop _________________ evidence deposited in blood.
latent friction ridge
166
Prior to using any indiscriminate process for collecting trace evidence, suspected surfaces should be carefully examined with both _____________ and a _______________ in an effort to visually locate trace elements.
white light and forensic light source
167
Trace items discovered by using a white light or a forensic light source should be photographed using the ______________________.
comparison photography method
168
Trace elements may be easily lost if not __________________.
carefully handled
169
The method of collection must be tailored to the ____________ of evidence being collected.
type and size
170
Some trace items may be very easily collected with a ______________ or _________________ while others may require a small piece of tape or other adhesive to securely collect.
gloved hand or sterile tweezers
171
Mikrosil casting material is used to make _________________ casts of bullet defects.
high resolution
172
To cast bullet defects, tool mark, or other impressions, use _____________ colored Mikrosil.
gray or brown
173
_________________ are preferred to by tool mark and firearms examiners for the contrast provided for microscopic comparison examinations.
Gray and brown
174
A chemical reagent ________________ is utilized to test a suspected bullet defect in an immovable object for the presence of copper.
rubeanic acid
175
If test for both lead and copper are contemplated, the _____________ copper test must be sequenced first.
copper
176
To prevent contamination of the chemicals when testing for copper, do not allow the ________ to come into contact with the swab.
dropper
177
Before being used to test a suspected bullet defect, a control test should be performed upon a known standard containing copper (e.g., _________________________________.
a piece of copper wire or a penny
178
The rubeanic acid reagent also reacts positively to ______ and ______.
nickel and cobalt
179
A small glass dropper bottle containing ______________________________ and a small glass dropper bottle containing ___________________ of rubeanic acid solution.
12% ammonium hydroxide solution 1% ethanol solution
180
A presumptive positive test result for the presence of copper is indicated by an immediate ___________ colored reaction.
green-black
181
The field test for copper should only be used to field test _________________.
immovable objects
182
Whenever possible the actual suspected bullet defect should be _______ and submitted for crime laboratory analysis.
excised
183
A chemical reagent (Sodium Rhodizonate) is utilized to test suspected bullet defects in ____________________ for the presence of lead.
immovable objects
184
Before being used to test a suspected bullet defect, a positive control test should be performed upon a known standard containing lead (e.g., _____________________________).
a bullet, a lead fishing weight, etc.
185
The sodium rhodizonate solution used to test a bullet defect for the presence of lead has a very short shelf life (_____). Therefore, it must be used at the scene.
1 day
186
The sodium rohodizonate solution also reacts positively to other heavy metals (e.g., ______, etc.).
Barium, Strontium, Etc.
187
A small glass dropper bottle containing pre-mixed solution of ______________ and sodium rhodizonate powder are needed to test for the presence of lead.
15% acetic acid
188
The presumptive positive result for the presence of lead is indicated by a __________ color reaction.
red-violet