Dat Gustaf Doe Flashcards Preview

light > Dat Gustaf Doe > Flashcards

Flashcards in Dat Gustaf Doe Deck (28)
Loading flashcards...
1
Q

When was the Gustaf first produced?

A

1964

2
Q

What is the penetration of the HEAT round?

A

400m RHA

3
Q

What does the stop protection do?

A

Retains the venturi locking lever in the forward position when the venturi is open

4
Q

What does the safety protection do?

A

Prevents full travel of the firing rod and cam plate when the Venturi is fully closed

5
Q

What does the locking protection do?

A

Locks the Venturi in the closed position

6
Q

Where are the three projections located?

A

On the Venturi latch lever

7
Q

What is the max effective range of the ADM 401?

A

100 meters

8
Q

What is the ADM 401 made for?

A

Close in protection in jungle or urban warfare (flechette and ball bearings)

9
Q

What is the HE 441D round designed to combat?

A

Troops in the open, behind cover, in slit trenches, or soft skinned vehicles.

10
Q

Which round has a time mode for air burst?

A

HE 441D

11
Q

What is the effective range of the HE 441D?

A

Airburst: 1250 meters
Impact: 1300 meters

12
Q

What target is the HEAT 551C made for?

A

Armored vehicles

13
Q

What is the effective range of a HEAT 551C round?

A

700 meters

14
Q

What makes a HEAT 751 different from the HEAT 551C round?

A

It has a tandem warhead

15
Q

What is the effective range of an HEDP 502 round?

A

Moving targets: 300m

Buildings: 500m

16
Q

What is the max effective range for an HEDP 502 round on troops in the open?

A

1000 meters

17
Q

What is the burn time for an illumination round?

A

30 seconds

18
Q

What degree should the gun be at for targets more than 800m when firing illum?

A

20 degrees

19
Q

What degrees should the gun be at for firing illum at less than 800m?

A

25 degrees

20
Q

What rounds match the first setting on the fire control device?

A

HEAT 551, TP 552

21
Q

What rounds match the second setting on the fire control device?

A

HE 441
ADM 401
SMOKE 469

22
Q

What rounds match the third setting on the fire control device?

A

HEDP 502 RS

23
Q

What rounds match the fourth setting on the fire control device?

A

509B ASM

24
Q

What temperature dictates hot ammunition, and what color is that setting?

A

Above 86 degrees, red.

25
Q

What temperature dictates normal ammunition, and what color is that setting?

A

32-86 degrees, White.

26
Q

What temperature dictates cold ammunition, and what color is that setting?

A

Below 32 degrees, Blue.

27
Q

How big is the danger area of the Gustaf?

A

40 meters at 90 degrees

28
Q

How big is the caution area of the Gustaf?

A

100 meters at 90 degrees.