Dataman 470 Series Flashcards
(28 cards)
These are the two Dataman 470 Series models available.
Dataman 474 and 475
What algorithms does the Dataman 470 series utilize?
1DMax, 2DMax, Hotbars, PowerGrid
This is the image sensor used by the Dataman 474.
1/1.8″ CMOS
This is the image sensor used by the Dataman 475.
2/3″ CMOS
What are the image sensor properties of the Dataman 474 model?
Diagonal 8.9 mm; 3.45 µm square pixels
What are the image sensor properties of the Dataman 475 model?
Diagonal 11.1 mm; 3.45 µm square pixels
What is the resolution of the Dataman 474 model?
2048 x 1536 (3MP)
What is the resolution of the Dataman 475 model?
2448 x 2048 (5MP)
What is the electronic shutter speed(µs) of the Dataman 470 Series readers?
Min. exposure: 15 µs
Max. exposure: 1000 µs with internal illumination/10000 µs with external illumination
What is the maximum acquisition speed of the Dataman 474?
Up to 80Hz
What is the maximum acquisition speed of the Dataman 475?
Up to 55Hz
What are the lens options for all Dataman 470 Series readers?
Liquid lens 10 mm, 16 mm, 24 mm; C-mount 12 mm, 16 mm, 25 mm, 35 mm, 40 mm
True/False: The Dataman 470 Series readers do not have trigger and tune buttons on them?
False: All Dataman 470 series readers have trigger and tune buttons for quick setup intelligent tuning
Is the aimer optional or mandatory on all Dataman 470 Series readers?
Optional
How many inputs and outputs do the Dataman 470 Series readers have?
Inputs: 2 fixed + () opto-isolated
Outputs: 2 fixed + () opto-isolated
What other I/O points are available on the Dataman 470 Series?
2 user-configurable
What status outputs are available on the Dataman 470 Series reader?
Beeper, 5 multifunctional LEDs, 10 LED bar array, 360 degree indicator
What lighting options are available for the Dataman 470 Series?
Integrated LEDs, red, blue, or IR; diffuse, polarized, high
powered integrated light (HPIL), high powered integrated
torch (HPIT), various controllable external light options
**Dataman 475 does not have the HPIL option
What communication options are available for the Dataman 470 series?
Ethernet and Serial
What protocols are available for the Dataman 470 series?
RS-232, TCP/IP, PROFINET, EtherNet/IP(TM), SLMP, Modbus TCP, NTP, SFTP, FTP, MRS
Java Scripting enabled for custom protocols
What power input is required for the Dataman 470 Series readers?
24 VDC ±10%
What power consumption is there for the Dataman 470 Series?
24 VDC ±10%, 1.5 A maximum (HPIL/HPIT1)
24 VDC, 250 mA maximum (reader)
Supplied by LPS or NEC class 2 only
How much do the Dataman 470 Series Readers weigh?
373g
What is the operating temperature of the DAtaman 470 Series Readers?
0–57 °C (32–134.6 °F)²
² In situations where the operating temperature exceeds 40 °C, an external heat sink is required.