Dc Flashcards

(58 cards)

1
Q

Transverse bulkheads

A

9, 10, 16, 22, 28, 36, 44, 52, 64, 70, 76, 82, 88

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Fire zone bulkheads and what is special about them

A

28, 52, 76. They are fireproof due to the coating

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Members of a attack team

A

Nozzleman, hoseman, plugman

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Mission oriented protective posture(MOPP) levels

A

MOPP 0: NO THREAT.
MOPP 1: ATTACK SUSPECTED
MOPP 2: ATTACK POSSIBLE
MOPP 3: ATTACK PROBABLE
MOPP 4: ATTACK IMMINENT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Counter measure wash down(Cmwd zones)

A

Zone 1: focsle
Zone 2: fwd of the super structure
Zone 3: aft super structure
Zone 4: flight deck
Zone 5: fantail

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

5 fire pump locations

A

Bow thruster room
Amr (gen 1)
Fmmr (gen 2)
Ammr (main prop)
Pump room 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Firemain activations

A

Locally(panel next to pump)
Remotely(grey activation box outside of space)
MCMS
MAG SPRINKLERS
AFFF

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Places with installed AFFF

A

AMR
FMMR
AMMR
GEN3
INCINERATOR ROOM
JP5
PORT AND STBD HANGAR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

AFFF HOSE LOCATIONS

A

Amr (stbd)
Fmmr (port)
Ammr (port)
Fantail
Port and stbd hangar
Gen3 (soft hose)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Water mist locations

A

Amr
Fmmr
Ammr
Gen3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Fm200 spaces

A

Hazmat locker
Flammable liquids locker
Paint locker

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Indirect vs direct fire fighting

A

Wide v: Fighting smoke and spreading over wide areas

Straight beam: fighting fire directly or ricocheting off walls to fight indirectly

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Main drainage activation process

A

Location in stbd FMMR
1 Discharge/
2 firemain/
3 suction/

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Where to activate water mist

A
  1. MCMS
  2. Push buttons between the scuttle and QAWTD in AMR, AMMR, AND FMMR
  3. Push buttons by the escape trunks in AMR, FMMR, AND AMMR
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Escape trunks in AMR, FMMR, AMMR

A

AMR: Lowest level port side. Leads all the way to main deck. Pops out AFT of pelican/FWD of wardroom

FMMR: lowest level stardboard side. Leads to main deck. Pops out FWD of ECR + into incinerator room

AMMR: lowest level FWD port side. Leads to main deck. Pops out into ECR + FWD STBD side into laundry #2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What are the installed firefighting systems

A

1 AFF
2 WATER MIST
3 MAG SPRINGKLERS
4 FIREMAIN
5 CO2
6 FM200
7 Apc

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

How many fire pumps do u need for CMWD

A

4 pumps

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

What are the Firemain crossconnects

A

Emergency asw
Emergency asw for gen3
Afff
Vcht
CMWD
Main drainage
Mag sprinklres
Trash room

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

E stop locations

A

AMR: on the gen, vcht, and outside the space

FMMR: on the gen and outside the space

AMMR: on the gen and outside the space

GEN3: on the gen and outside the space

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Where are the taco switches

A

One master one in ECR

And one outside of each space

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

What is different about AMR escape trunk

A

It has AFF by it (others only have water mist)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Where are both water mist tanks

A

Water mist 1 tank is above it in laundry 1
Water mist 2 tank is aft of the galley next to dry store

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

FMMR fuel transfer pumps or fuel purifier issue

A

Use the taco switch to turn it off

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

How to depressurize the firemain

A

In anchod windless. Make sure u turn off the firemain and open both valves on port and stbd of the room

25
How do you use mag sprinkler and why do you wait
Open the tab, hold it for 3seconds, pull the valve to open until u hear water rushing, then pull it back to neutral so that it can be accessed through mcms
26
Where do they keep the 4inch hoses
Water mist 1 and upper annex
27
If someone is acting sus walking out of a restricted area what do u do
Try to stop them, if not, man the space, report it, and have them secure the brow
28
If theres a massive oil leak happening in a engine room what do u do
Report it immediately. E stop it, try to flow it down with aff as if its a fire into the bilge, if it ignites, still continue as a normal fire
29
How do you do draft readings
They are the number plus a 1 on the side. 20 being 20
30
Underway and in port mag sprinkler permissions
Co permission underway, ood permission inport
31
What are taco switches for
Vents, fuel, and auxiliary equipment
32
Whats special about countermeasure WD
You can use the MOV in jhawk to mix afff with cmwd to use it on the flightdeck
33
If the firemain ruptures, what can you do to supply the other side?
You can isolate the rupture and use a hose to jump it
34
How far apart are gun bags supposed to be
100feet or 10 seconds
35
Dc hierarchy in case of casualty
1 DCA IN DCC 2 LOCKER LEADED IN LOCKER 3 OSL ON SCENE 4 ATL ON SCENE
36
What sre the ways to desmoke
Natural ventilation Box fan Ram fan 2000 Vents
37
What does main drainage do
It drains all compartments below the waterline, with the main drainage eductor which can be powered by the firemain or balast pumps to a balast tank or overboard with CO permission
38
What is the collective protection system(CPS)
A zone where by using outward pressure from filtered air it keeps contaminants out like liquid, solids, or gases like CBR agents(bridge down to chiefs cross)
39
Tell me about shoring specs and where they are
3-5feet mechanical shoring: 12klb extended 20klb compacted 6-11ft mechanical shoring: 6klb extended 20klb compacted Wooden shoring: Douglas fur wood Yellow pine wood (Because they absorb water and expand) They are located close to repair lockers. Repair 3 has them in aft steering. Repair 2 has them right outside. anchor windless has the wooden shoring
40
Portable eductor specs and difference
Peri jet:: no strainer 2 1/2inch fire hose supply 4inch fire hose discharge 500 GPM DISCHARGE S type:: uses strainer 1 1/2inch fire hose supply 2 1/2inch fire hose discharge 265 GPM DISCHARGE
41
2 main drainage pumps where and GPM
375 GPM One in AMR and one in AMMR
42
What are firemain pumps rated for
1000GPM at 125psi
43
Types of fire and ext for them
ALPHA: embers, wood, paper(water, afff) BRAVO: flammable liquids(afff, pkp, co2) CHARLIE: electrical(turn off, co2) DELTA: combustible metals(jettison or sand
44
Where do they keep the 4inch hoses
In water mist 1 and the upper annex
45
Desmoking specs
Box fan: 3200 cubic feet of air per minute. 2 each in repair 2 and 3 Ram fan 2000: first ground it. 1 each in repair 2 and 3. Powered by the firemain with a 1 1/2 hose at 1640 to 1950 cubic feet per minute depending on the pressire
46
What do you want if u use p100 inside
Exhaust pipes to get rid of the co2
47
P100 lift capacity
20ft lift at 83PSI 40ft lift at 45PSI
48
Shoring kit
C clamp Wedges Mallet Measuring tape
49
Plugging kit
Wood plugs Handsaw Hammer Cold chisel
50
Patching kit
Syntho glass Hacksaw Wood wedges Wood chisels
51
Afff station locations
One by ECR One by water mist 1 by repair 2
52
Water mist station locations
1 by the fwd afff station 1 by reefers
53
Peri jet and s type locations
For repair 3 theres some in the room infront of the gym as well as the room before aft steering For repair 2 theres some inside the locker as well as inside the water mist station 1
54
How many p100s on board and where. Plus discharge and suction
2 in the focsle 2 in the fantail 2 1/2discharge 3inch suction 100gpm 20ft lift 68gpm 40ft lift
55
Apc system temperature to melt
360f
56
9 man and 13man positions
OOD JOOD RPE ATL EOW 2investigators Nozzleman Hoseman For a 13man you add 3boundaryman and 1 plugman
57
Electrical submersible pumps(ESP)
2 in each repair locker inside the respective water mist stations. 200Gpm 50ft head 140Gpm 70ft head Has a 2 1/2inchdischarge and can be ran in tandem by using 2 1/2inch double female adapter. Connected to the 440v plugs
58
Where to connect p100s for firemain replacement
Manifolds found::: Pt and stbd of the focsle. Fantail Fas deck/boat deck