E-stim Parameters Flashcards
(67 cards)
Muscle strengthening - pulsed biphasic
Waveform?
pulsed symmetrical biphasic on tower machine OR VMS on non-tower machine
Muscle strengthening - pulsed biphasic
Pulse frequency?
20-100 Hz or pps
Muscle strengthening - pulsed biphasic
Pulse duration?
125-600 microseconds
125-200 microseconds small
200-350 microseconds large
Muscle strengthening - pulsed biphasic
Amplitude?
strong visible contraction max tolerated
10% of MVIC for injured muscle
>50% for non-injured muscle
Muscle strengthening - pulsed biphasic
on : off time?
1:5 (10:50)
May decrease as patient progresses
Muscle strengthening - pulsed biphasic
Ramp?
2sec, depending on patient
Muscle strengthening - pulsed biphasic
Treatment time?
10-20 min to produce 10-20 reps 3-5x/week
Muscle strengthening - pulsed biphasic
Electrode placement?
Parallel with muscle fibers over motor points
Muscle strengthening - Russian
Waveform?
medium frquency burst alternating current
Muscle strengthening - Russian
Pulse frequency?
Carrier frequency preset at 250,000 hz
Burst 50 Hz
Duty cycle 50%
Muscle strengthening - Russian
Pulse duration?
preset at 10 milliseconds
Muscle strengthening - Russian
Amplitude?
Strong visible contraction max tolerated
10% MVIC for injured muscle
50% MVIC for non-injured muscle
Muscle strengthening - Russian
on : off time?
1:5 (10:50)
decrease as patient progresses
Muscle strengthening - Russian
Ramp?
2 sec depending on patient
Muscle strengthening - Russian
Electrode placement?
parallell with muscle fibers over motor points
FES/Muscle Re-education
Waveform?
Could use pulsed symmetrical bi-phasic or Russain
FES/Muscle Re-education
Pulse frequency?
dependent on Russian or biphasic current
FES/Muscle Re-education
Pulse Duration?
dependent on Russian or biphasic current
FES/Muscle Re-education
Amplitude?
sufficient contraction for activity
FES/Muscle Re-education
on:off time, ramp, treatment time?
activity dependent
FES/Muscle Re-education
Electrode placement?
parallel with muscle fibers over motor points
Edema reduction due to acute inflammation
Waveform?
High volt pulsatile current (HVPC)
Red wire is active
Edema reduction due to acute inflammation
Pulse frequency?
100-125 pps
present on machines
Edema reduction due to acute inflammation
Pulse duration?
2-100 microseconds
present on machine