1
Q

What is the best type of push-button operator to use in an emergency stop application?

A

Jumbo Mushroom

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

A selector switch with a legend plate labeled SLOW/FAST is an example of what type of selector switch?

A

2 Position

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A selector switch with a legend plate labeled SLOW/OFF/FAST is an example of what type of selector switch?

A

3 Position

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

In a truth table, X represents what contact condition?

A

Closed Contact

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

In a truth table, O represents what contact condition?

A

Open Contact

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the main advantage of using a joystick in an application such as moving the passenger loading ramp for an airplane?

A

Control many operations without removing hand

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

In a joystick symbol, what does the dot denote?

A

Position needed to actuate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

If the moving part of a limit switch is drawn below the contacts in the symbol, is the switch NO/NO held closed or NC/NC held open?

A

NO/NO held closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

If the moving part of a limit switch is drawn above the contacts in the symbol, is the switch NO/NO held closed or NC/NC held open?

A

NC/NC Held Open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What type of limit switch actuator allows detection of a moving object from any direction except head on?

A

Wobble Stick

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What type of limit switch actuator allows the arm length to be adjusted to meet the application?

A

Lever Arm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When a foot switch has 3 positions, does the toe operate all 3?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Is the OFF position of a foot switch usually a maintained position or a spring loaded position

A

Spring Loaded

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What does a pressure switch rated in inches of W.C. refer to?

A

Inches of Water Column

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

If a pressure switch is used to maintain a set pressure, are NO or NC contacts used to control the compressor motor starter?

A

NC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

If a temperature switch is used in a heating system to maintain a set temperature, are NO or NC contacts used to control the heating contactor?

17
Q

If a temperature switch is used in a cooling system to maintain a set temperature, are NO or NC contacts used to control the cooling contactor?

18
Q

If a flow switch is used to sound an alarm when there is no flow, are NO or NC contacts used to control the alarm?

19
Q

If a flow switch is used to detect flow in an automatic sprinkler system that had detected a fire and opened the sprinklers to flow, are NO or NC contacts used to control the alarm?

20
Q

If a level switch is used in a charging system, are NO or NC contacts used to control the pump motor starter?

21
Q

If a level switch is used in a disharging system, are NO or NC contacts used to control the pump motor starter?

22
Q

Is a diode used to help protect electrical contacts in an AC or DC load switching circuit?

23
Q

What position are most flow switches designed to operate in?

24
Q

If voltage is measure on the incoming side of a switch, but not on the outgoing side, what is the state of the switch?

25
If voltage is measured on both sides of a switch, what state is the switch in?
Closed
26
What do most flow switches use?
A paddle
27
What does CEMF stand for?
Counter Electro-Motive Force
28
Can 1 push-button operate both NO and NC contacts?
Yes