Engine Company Handbook Flashcards

1
Q

Engine Company Handbook

All Sacramento Fire engine apparatus meet the specifications and standards as outlined by the NFPA __________________.

A

1901-Standard for Automotive Fire Apparatus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Engine Company Handbook

Sacramento Fire engines have permanently mounted centrifugal fire pumps which can produce up to __________ their rated capacity with adequate water supply from a hydrant.

A

twice

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Engine Company Handbook

Securing a water supply is a top priority but does not supersede the need to establish an ___________________.

A

interior attack hose line

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Engine Company Handbook

The hose beds on a Sacramento Fire engine are configured to perform both ________ and __________ operations.

A

supply / fire attack

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Engine Company Handbook

Each engine has two ___ inch intakes equipped with a ball-intake valve.

A

6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Engine Company Handbook

All engines have a permanently mounted fire pump with a rated discharge capacity of at least ____ gpm.

A

1,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Engine Company Handbook

On a Type VI unit, how many gallons does the water tank hold?

A

400

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Engine Company Handbook

How much 3” hose is in a flat load on a Type 1 engine?

A

600

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Engine Company Handbook

The primary mission of an engine is to provide ______ ________ for fire streams.

A

adequate pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Engine Company Handbook

The Dash class engine is outfitted with a ________ pump, while the Velocity and the Enforcer classes are outfitted with a _______ pump

A

two-stage / single stage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Engine Company Handbook

All of the hose used by Sacramento Fire meets the requirements set forth by the NFPA _________.

A

1961-Standard on Fire Hose

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Engine Company Handbook

In the three-inch hose bed, small hand loops will be placed every _______ on the _______ stack.

A

50’ / right

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Engine Company Handbook

The primary causes of damage to fire hose are _______, _______, and ________.

A

mechanical / thermal/ chemical

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Engine Company Handbook

The polyester hose jacket can melt in the range of ______.

A

500 F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Engine Company Handbook

Have the Sacramento Fire Hose Shop service-test hose if there is suspicion of a ________ exposure.

A

chemical

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Engine Company Handbook

After such chemical exposures, hose must be thoroughly washed as soon as possible with _______, _______ water.

A

warm, soapy

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Engine Company Handbook

The two primary types of hose couplings used by the Sacramento Fire are ________ and _________.

A

threaded / Storz

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Engine Company Handbook

National Pipe Straight Hose (NPSH), also known as “pipe thread”, is used on __________ hose.

A

1” forestry

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Engine Company Handbook

To ensure each section of hose is eventually rotated throughout the entire hose bed, the _________ method will be followed.

A

“first-to-last”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Engine Company Handbook

Remove _______ and ______ from the hose before placing it back into hose beds as this is a leading cause to the breakdown of the fibers in the jacket.

A

dirt / grit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Engine Company Handbook

When hose is sent in for repair, place an ______ next to its inventory number in the “Hose Rack” box.

A

“x”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Engine Company Handbook

Company officers are responsible for ensuring that newly received hose undergoes the _______ ______ process.

A

service test

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Engine Company Handbook

All fire hose will undergo service testing on an _______ basis and after any ________ are made.

A

annual / repairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Engine Company Handbook

Maximum length of hose to be tested per engine outlet is ______ feet.

A

300

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
# Engine Company Handbook Secure hose lines with rope and keep personnel at least _____ feet away from the testing area.
25
26
# Engine Company Handbook The 1 ¾” nozzle is a _______ \_\_\_\_\_\_ flow nozzle with an effective reach of ______ feet.
constant gallonage / 110
27
# Engine Company Handbook Fittings are identified in order by: \_\_\_\_\_\_\_; \_\_\_\_\_\_\_\_; \_\_\_\_\_\_\_.
size / direction of flow / fitting name
28
# Engine Company Handbook Size of the fitting listed as _______ side first, _______ side last.
female / male
29
# Engine Company Handbook An _______ is defined as any device through which water passes.
appliance
30
# Engine Company Handbook The adjustable pressure relief dump valve has a range from ___ to ___ psi and can unload up to ______ gallons.
50 / 300 / 1,000
31
# Engine Company Handbook The dump valve should be set to ______ psi on the intake located on the engineer’s panel and _____ psi on the officer’s side panel.
75-90 / 150
32
# Engine Company Handbook The LDH manifold has a pressure relief dump valve which ranges from ___ to ___ psi.
75 / 250
33
# Engine Company Handbook There are three basic types of hydrant wrenches that can be found on any Sacramento Fire engine company: \_\_\_\_\_\_\_\_, \_\_\_\_\_\_\_\_, and \_\_\_\_\_\_\_\_.
adjustable hydrant/spanner wrench / Corey Hydrant wrench / five-hole hydrant wrench
34
# Engine Company Handbook The hose roller is located on all _______ companies.
truck
35
# Engine Company Handbook FireAde has a working foam concentrate ranging from ___ percent to ____ percent.
0.1 / 3
36
# Engine Company Handbook How many gallons of foam concentrate are needed to make a 3 percent mixture for one booster water tank worth of water?
15
37
# Engine Company Handbook What is the rating for the Dry Chemical extinguisher?
2A: 10B: C
38
# Engine Company Handbook The use of an aerator can increase the foam blanket by up to ____ percent.
45
39
# Engine Company Handbook What are the two simple ideals of the Sacramento Fire Department?
The fire goes as the first line goes, If you put the fire out, everything gets better
40
# Engine Company Handbook The company officer’s responsibilities at a structure fire can be broken into what 3 basic phases?
Responding to, on arrival, suppression
41
# Engine Company Handbook The officer has several options for securing a water supply, name the 6?
1) tank water 2) lay-in wet 3) lay-in dry 4)lay-out 5) split lay 6) hand-jack
42
# Engine Company Handbook What are the 3 operational modes of the incident for a company?
Investigation, fire attack, command
43
# Engine Company Handbook Second and subsequent arriving companies base their operations on the \_\_?
Initial actions taken by the first company
44
# Engine Company Handbook The _____ \_\_\_\_\_\_ is the accepted department standard for providing updates to incoming companies or the established incident commander.
C.A.N. Report
45
# Engine Company Handbook The first arriving officer, and/or back-up firefighter must control ___ \_\_\_\_\_ when possible.
The door
46
# Engine Company Handbook What 3 basic responsibilities does the engineer have during fire operations?
Delivering the crew and apparatus safely to the scene; pumping operations; securing a water supply
47
# Engine Company Handbook Third and later-arriving engines should consider taking a position where to provide additional hose lines if necessary?
In the alley behind the structure
48
# Engine Company Handbook If the structure is set back greater than \_\_\_\_, consider using the 200’ tank line.
100 feet
49
# Engine Company Handbook The ____ tankline should NOT be the first line stretched as it would require it to be backed-up with 3” and Sac Pack.
300’
50
# Engine Company Handbook For fires in public hallway apartment buildings and complexes (garden style), the _____ and _______ may be the most efficient option.
3” supply line, Sacramento Pack
51
# Engine Company Handbook What are 3 situations that commonly require the second-arriving engine company to assist with the advancement of the first line?
Upper floor fires, basement fires, 2½” hose line operations
52
# Engine Company Handbook The back-up firefighter should include what 2 things in their tool selection while in investigation mode?
The water can and the irons
53
# Engine Company Handbook For subsequent arriving engines, what 4 tasks should only be completed after the initial attack line has been stretched and is advancing into the fire?
1) Assume command; 2) water supply; 3) stretch additional hose lines; 4) staging
54
# Engine Company Handbook What is the primary consideration at any fireground operation?
The protection of life
55
# Engine Company Handbook What shall deter the nozzle firefighter from getting the nozzle to the seat of the fire?
NOTHING
56
# Engine Company Handbook What are the three phases of the logical sequence of firefighting, according to FDNY Deputy Chief Emamuel Fried?
Phase 1 - locate the fire; Phase 2 - Confine the fire; Phase 3 - Extinguish the fire
57
# Engine Company Handbook Initial extinguishment includes _____ of visible flames and extinguishment of smoldering debris.
“knockdown”
58
# Engine Company Handbook What method of fire attack is generally accepted as the preferred way and is the way that the Sacramento Fire recommends for fire attack?
Direct method
59
# Engine Company Handbook Which method is the most common method and involves the direct application of water on the burning fuel to cool it below its ignition temperature and eliminated production vapors that burn?
Direct Method
60
# Engine Company Handbook At a ceiling temperature of 1,0000F or more, water expands over ______ times its original volume.
4,000
61
# Engine Company Handbook Transitional fire attack is not a method intended __ \_\_\_\_\_\_ \_\_\_\_\_\_\_.
For getting extinguishment
62
# Engine Company Handbook A single engine company can only effectively stretch ____ \_\_\_\_ \_\_\_\_\_.
One hose line
63
# Engine Company Handbook What is not an appropriate technique for the application of water?
“Penciling”
64
# Engine Company Handbook Prior to advancing the hose line to upper floors, it is always a good practice to ____ \_\_\_\_ ____ before proceeding to an upper floor position.
Check the lower floors for fire
65
# Engine Company Handbook During transitional fire attack, how long should the solid/straight stream be held steady and flowed at a 450 angle at the upper levels of the room?
6 to 10 seconds
66
# Engine Company Handbook More lives are saved at fires by the proper ______ and _____ of hose lines than by all other means.
Positioning, operating
67
# Engine Company Handbook What are the three essential fundamentals that must be followed every time a hose line is stretched?
Determine the location of the fire before beginning a stretch; determine proper size hose; estimate the amount of hose needed
68
# Engine Company Handbook What is the most important decision that the engine company officer will make after determining the location of the fire?
Which hose line to stretch
69
# Engine Company Handbook It is an accepted practice that the minimum flow rate for interior operations in residential structures should be \_\_\_\_\_\_.
150 gpm
70
# Engine Company Handbook The acronym _____ can assist the engine company officer in determining when a ___ hose line is an appropriate choice.
“ADULTS”; 2½”
71
# Engine Company Handbook When should a 2½” hose line be put into service without first securing a water supply?
Only under extreme circumstances
72
# Engine Company Handbook To help determine the amount of 2½” needed, what is the rule of thumb for commercial buildings?
Length + Width + 50 feet
73
# Engine Company Handbook The tactic of stretching the first hose line via the primary means of egress allows what 2 things?
Occupants to evacuate via the stairs; members to proceed above the fire for search
74
# Engine Company Handbook What 3 fire conditions warrant the use of a second hose line for fire attack?
The volume of fire creates the need; fire on a lower floor of a multi-floor occupancy; exposure protection
75
# Engine Company Handbook Department SOGs allow the advancement of the 2OUT hose line in what 4 situations?
An additional attack hose line is needed; pressure loss to the attack hose line is experienced; nozzle team is trapped by fire; truck company members’ egress is cut off
76
# Engine Company Handbook The 2OUT hose line must be what in regards to the attack line?
The same diameter, or larger than
77
# Engine Company Handbook Do not ____ \_\_\_\_ using the 2OUT line.
Fight the fire
78
# Engine Company Handbook To assure efficient and timely stretching of the fire attack hose line in multiple-story buildings, the services of the first ____ \_\_\_\_\_ companies should be utilized.
Two engine
79
# Engine Company Handbook A charged hose line is _____ times more difficult to move.
Six
80
# Engine Company Handbook What are 4 methods in which a firefighter can physically advance the hose line?
Crawling; duck walking; leg forward; pin and hit
81
# Engine Company Handbook Garage fires that have living quarters over the garage will require the use of a minimum of how many lines?
Three attack lines
82
# Engine Company Handbook When must windows of a basement be properly vented as the initial hose line makes entry and begins fire attack?
Simultaneously
83
# Engine Company Handbook What is the best way to protect exposures, both interior and exterior?
Rapidly and aggressively put the fire out from the interior
84
# Engine Company Handbook Exterior exposure lines should almost always be what size hose line?
2 ½”
85
# Engine Company Handbook It is common to have ____ feet or less between adjacent Victorians.
five
86
# Engine Company Handbook What is another construction feature that adds to the difficulty of extinguishment in garden apartments?
They have a common attic
87
# Engine Company Handbook These types of apartments get called or are confused with garden style apartments.
Exterior Hallway Apartments
88
# Engine Company Handbook The ______ is a vertical opening within the center of the stairway that permits a single 50’ length of hose to reach from the first to the fourth floor.
Wellhole
89
# Engine Company Handbook A unique stairwell construction feature known as a “\_\_\_\_\_\_” or “\_\_\_\_\_\_\_” exists in many of the older residential high-rises in Sacramento.
Fire-tower; smoke-proof tower
90
# Engine Company Handbook Wet standpipe systems installed prior to ___ are required to provide only _____ psi residual pressure at the building’s highest standpipe outlet.
1993; 65
91
# Engine Company Handbook The decision to use the Sacramento Pack should be made only when a ___ standpipe is used or a ___ standpipe with a minimum of ____ residual pressure.
Dry; wet; 100 psi
92
# Engine Company Handbook Commercial fires will dictate specific actions in specific order, what are the 4 actions?
1) locating the fire; 2) apparatus placement; 3) water supply; 4) forced entry
93
# Engine Company Handbook Most fires involving the residence of a Taxpayer can be successfully fought with what size hose line?
1¾”
94
# Engine Company Handbook Typical tilt-up warehouses have what type of roof construction?
Lightweight panelized
95
# Engine Company Handbook A general guideline to follow is do not operate more than ___ inside a commercial building unless absolutely necessary.
150’
96
# Engine Company Handbook For a majority of these types of buildings (strip mall), the roof assembly is constructed with a flat, \_\_\_\_\_\_\_\_\_\_\_\_, with newer styles incorporating \_\_\_\_\_\_\_\_\_\_.
Lightweight roof wood truss; open-web bar joists
97
# Engine Company Handbook Prior establishment of a permanent water supply is required when?
Flowing a second hose line
98
# Engine Company Handbook The engineer may elect to hand-jack the supply line to the plug where the hydrant is within ___ of the engine.
100 feet
99
# Engine Company Handbook Who determines the type, size, and spacing of its hydrants?
Each water district
100
# Engine Company Handbook Where can a Clow Hydrant be found?
Commercial or industrial occupancies
101
# Engine Company Handbook Whenever possible, the engine company should _____ a warf for a _____ \_\_\_\_\_\_.
Pass; regular hydrant
102
# Engine Company Handbook A 4½” hydrant outlet will deliver ____ gpm with a flow pressure of 15psi.
2,100
103
# Engine Company Handbook According to color coding standards within the city, what is the water capability of a red hydrant.
Less than 500 gpm
104
# Engine Company Handbook Who will remain at the hydrant when utilizing the “wet” forward lead?
The back-up firefighter
105
# Engine Company Handbook The first-arriving engine MUST transmit on the radio its intention to start a ___ lay.
split
106
# Engine Company Handbook During emergency operations, it is permissible to ____ \_\_\_\_\_ hose lines.
Drive over
107
# Engine Company Handbook A Class I standpipe is for _______ use only.
Fire department
108
# Engine Company Handbook A Class II standpipe has what size outlet?
1½”
109
# Engine Company Handbook Prior to 1993, the riser had to provide ____ gpm at 65psi residual pressure.
500
110
# Engine Company Handbook Current NFPA standards require a minimum of \_\_\_\_psi at the top outlet.
100
111
# Engine Company Handbook What is the most common type of flow-restricting device?
Orifice plate
112
# Engine Company Handbook Sacramento Fire SOGs allow crews to use the elevators for fires above the ____ floor.
Seventh
113
# Engine Company Handbook Each engine company crew assigned fire attack will bring all three 2½” high-rise bundles along with what 3 other items?
High-rise kit; gated wye; a forcible entry tool
114
# Engine Company Handbook Where should all standpipe hookups be made?
The floor below the fire
115
# Engine Company Handbook Where can additional hose lines be attached if needed? (2)
1) two floors below; 2) standpipe outlets in more distant stairways
116
# Engine Company Handbook The decision to use the Sacramento Pack in residential high-rise buildings should only be made when certain criteria have been met, what are they? (2)
1) A dry or wet system with a residual pressure of at least 100 psi; 2) the fire is confined to one unit with no fire present in the public hallway
117
# Engine Company Handbook Sacramento Fire engines companies carry what two separate master stream devices?
The “Stinger”; the “RAM” or “QAM”
118
# Engine Company Handbook The ____ \_\_\_\_ is a built-in safety feature that prevents the nozzle from being accidentally rotated too low.
Limiter pin
119
# Engine Company Handbook When a master stream strikes a fuel load, its cooling capability is _______ to its flow rate.
Proportional
120
# Engine Company Handbook Thought should be given to use more master streams through large ______ openings at ______ level.
Horizontal; ground
121
# Engine Company Handbook A stream of sufficient volume will extinguish all of the fire it can in \_\_\_\_\_\_\_\_.
Less than a minute
122
# Engine Company Handbook The engine company is best served by leading _____ the truck ____ the water supply.
From; to
123
# Engine Company Handbook What are the three most common uses of the manifold in Sacramento Fire?
1) supplemental water supply; 2) multiple hose lines/master streams; 3) ladder pipe operations
124
# Engine Company Handbook Which way should the directional arrow on the manifold point in relation to the ladder pipe?
Towards the ladder pipe
125
# Engine Company Handbook What should always be remembered to use on the manifold when connecting a 2½” line?
The high rise gauge
126
# Engine Company Handbook When the relief valve is correctly set on the manifold, what will be the indication?
A small trickle of water will be seen exiting the dump valve