Validity of building permit if the project is not commenced after its issuance
Within a period of ONE(1) YEAR from the date of such permit
Administrative fines to be imposed for failure to post certificate of occupancy/use/operation.
LIGHT VIOLATIONS- a fine of P 5,000.00
An opening of an attic shall not be less than how many millimeters in diameter?
600 millimeters
Maximum door leaf width of an exit door based on National Building Code of the Philippines
1.20 METERS (4 FEET)
Radius for vicinity map/location plan that must be presented for hospital project.
2 KM RADIUS (HALF KM IF RESIDENTIAL)
If only one (1) RROW services a lot and such is only 6.00 to 7.00 meters wide, what will be the building height limit of the structure?
Max is 3 storeys but not more than 9 meters
Minimum clearance between the established grade of the street and/or side walk and the lowest under surface of any part of the balcony based on NBC
3 meters
Size of an average automobile (car) parking slot for parallel parking
2.15 X 6 M.
Number of storeys that are required to be equipped with dry stand pipes based on NBC
4 OR MORE
Fences shall entirely enclose the construction/demolition site and shall be erected on the building side of sidewalks or walkways and shall be made of approved materials. How high should be the fence from the curb line?
2.4 meters
1 meter railing if with canopy
ndrails shall be placed not more than how many millimeters above the nosing of treads?
NOT LESS THAN 800MM NOR MORE THAN 900MM
NBCP - NOT MORE THAN 865MM (34IN) AND NOT LESS THAN 760MM (30IN)
These are areas within the lot that are with exposed soil and planted; this sub-classification is the true open space
UNPAVED SURFACE AREAS (USA) (like front yard/ FRONT SETBACK)
Amount of cash bond to be imposed for 80 cubic meter excavation
IN THE PHILIPPINES PHP 50,000.00 = FIRST 50 CUBIC METERS, ADD PHP 300.00 FOR EACH ADDITIONAL CUBIC METER BEYOND 50
Maximum floor area of a one storey and single detached building/structure to be exempted for structural analysis and design
20 SQM (ACCORDING TO NBCP)
The portion of a yard for which the permitted limit of paving/hardscaping shall not exceed 50% of the area of the yard
COURTYARD
Maximum center to center distance between the sprinklers based on the NBC
1.8 M
Minimum width of stairs for Group A Dwellings
750 MM
The physical development within a lot or property that is under-utilized, unfit/unsafe for habitation/use or within other lots/properties that are similarly situated
REDEVELOPMENT
How large should be the dispersal area of a two storey building with total floor area of 400 sq. meters if it has a capacity of 150 persons?
at least 42 sq. meters (150 persons x .28 sq.m/person) (annex A
A school building has 4 storeys, the first storey has occupant capacity of 300 persons, the second storey has 500 persons, the third storey has 400 capacity and the fourth storey has a capacity of 200 persons. How many exits will be the minimum number to be provided on the second storey?
3 EXITS
How much will be the amount of fine for failing to post the building permit construction information sign?
LIGHT VIOLATIONS - PHP 5,000.00
In a building equipped with a complete automatic fire extinguishing system, what will be the maximum travel distance to exit from any point of the building base on NBC?
60.0 METERS
Exterior doors and windows shall have how many hour/s of fire resistivity?
1-HR FIRE RATING
Where the walkway occupies part of the roadway or is adjacent to an excavation, what is the minimum height of required railings that shall be built substantially strong and sturdy as pedestrian protection during construction or demolition?
SHALL NOT BE LESS THAN 1.00 METERS