EPs Equipment Practical Flashcards
Learn operation, precautions, preflight checks of portable equipment (46 cards)
Pre flight check for portable oxygen x5
1/ secured in brackets, serviceable, correct number and location 2/ dust covers in place 3/ no oil or greeae on fittings 4/ oxygen mask attached 5/ min pressure 15,000 psi
Portable oxygen precautions x5
same for both apart from 1 for aero space
1/Prepare out of sight of pax 2/ Do not drop or bump 3/ no greesy hands 4/ never leave unattended 5/ do not let pressure gage drop below 50 psi, only do so in an emergency
(Aero space) -make sure on/off knob is turn completely on
Portable oxygen operation (scott) x8
1/ Remove from brackets
2/ remove oxygen mask stowage pouch
3/ put strap on over head and secure diagonally across body
4/ check the mask tubing has red O ring b4 attaching to HIFLOW outlet & checking the dust cover
5/ turn on control valve fully on, listen for sound
6/ place mask on pax head, adjust straps & pinch nose
7/ check no knick in tubing, monitor pax & pressure gage
8/ turn off when no longer required
Portable oxygen operation B/E aerospace x9
1/ Remove from brackets
2/ remove oxygen mask if required
3/ Ensure On/Off valve is in OFF position
4/ put strap on over head and secure diagonally across body
5/ check the mask tubing attachment has red O ring b4 connecting to the HIFLOW outlet 4L
6/ Start oxygen flow slowly, listen for sound
7/ place mask on pax head, adjust straps & pinch nose
8/ check no knick in tubing, monitor pax & pressure gage
9/ turn off when no longer required
Oxygen flow times
HI Flow 15,000 - 50psi ?
51min
Oxygen flow times
Low flow 15,000 - 50psi?
102min
Mega phone pre flight check
- Standard, secured in brackets
- Squeeze for autable click
Mega phone operation x6
Remove from brackets Hold towards pax Squeeze hand grip Speak Can ajust volume Activitie horn by pulling pin
Infant life jacket differences to adults/child?
1/ Lanyard for attaching infant life jacket to able body once outside aircraft
2/ Harness strap
3/ No whistle
Infant lifejacket operation
Tear open bag, remove lifejacket, put infant head through opening, place harness strap between legs, check stud is fastened, tighten harness strap to secure.
When do u inflate an Infant lifejacket & operation of inflation?
At an exit immediately proir to evacuating
Pull two red toggles to inflate
Use two oral mouthpieces for further inflation
To deflate push valve in center of mouthpieces
Once outside AC attach infant lifejacket lanyard to able body adult
Precautions of infant life jacket?
1/ Recommended for use by infants up to 4 years of ages or 16kg
2/ do not inflate infant lifejacket using oral mouthpieces b4 pulling on toggles as it may burst
( only to be given out in an emergency situation)
Handcuffs operation
How do you prepare handcuffs for use?
1/ prepare out of view of pax
2/ hold the handcuffs & set one side at a time
3/ gripping one side of handcuff, push the jaw through until the notch reaches the frame
4/ repeat again for other side of handcuffs
5/ the handcuffs are now set and ready for use
Handcuffs operation? X4
1/ Push the jaw firmly against the wrist of pax to be restrained. The jaw will flip through & teeth with engage
2/ to prevent handcuff from becoming to tight, use key to double lock, one at a time.
3/ visually check wire is no longer visible
4/ once pax has been restrained, re turn key to stowage
What are the handcuff precautions? X5
1/ be confident and assertive when using
2/ be careful not cause injury to the person being restrained
3/ avoid fitting over clothing
4/ offender shall not be restrained to any part of the AC at any time
5/ offender shall be able to walk freely if an evacuation is required
Handcuff preflight check?
Standard
Check handcuffs in stowage case
Check two keys are in front pocket of stowage case
Pre flight for BCF (fire extinguisher) ? X3
1/ standard
2/ safety pin in possession and secured with red plastic tie
3/ needle in green band of pressure gauge
BCF duration?
10 seconds
BCF operation? X5
1/ Remove from brackets
2/ Remove safety pin and red plastic tie
3/ Test spray ( hold upright)
4/ Aim nozzle at base of flames
5/ Use sweeping motion
BCF precautions? X13!
Use 1-2 m away from fire
Never hold BCF at an angle greater then 60°
Use of PBE is recommended
BCF is not a cooling agent
Ensure the nozzle points towards fire
Initial discharge can cause paper or fabric fires to scatter
Initial discharge may cause a flare up
Content of the BCF are toxic & can lead to dizziness, difficulty breathing, as well as eye, nose irritation
After discharge it can take up to 7min for agent to dissipate
Smoke should be cleared & signs of bcf content dissipated b4 removal of PBE or removal of oxygen masks
Leaks maybe difficult to detect
Note: if a BCF was found leaking report to CM & FD immediately and treated as a DG
BCF after use?
Replace safety pin
PBE duration?
15min
PBE pre flight check?
Standard
Check humidity indicator is not pink
Insure PBE is within expiration date checking the front of the PBE for date,
If unable to see expiry date on front of case, add 10 years to manufacturer date
PBE operation? X10
1/ Open box by lifting latch marked lift
2/Remove PBE from box
3/Grasp red strip with one hand & tear bag open
4/Remove PBE
5/ Pull ring marked “ Pull to actuate”
6/ Flow of oxygen will be heard, if not discard, get another
7/Widen next seal & put on PBE onto head
8/ Pull down to forehead to engage headband
9/ Ensure neck seal clear & maintained around the neck
10/ Pull PBE skirt down
REMOVEAL:
1/ Remove away from smoke or fire
2/ Brush hands through hair to break down oxygen build up