Q

Who is the DCTT Leader?

A

XO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Who are the first responders to a casualty underway

A

Flying Squad

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Rapid Response teams job

A

Go straight to scene and take appropriate actions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

how many personnel are assigned to the Rapid Response Team

A

4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Who are the members of the Rapid Response Team

A

Fire Marshal
Electrician
2 Investigators/Boundary Men

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the responsibility of the Rescue and Assistance team

A

Back up to the at sea fire party and assist other ships in distress

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What NSTM can you find information about surface ship fire fighting

A

NSTM 555

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

If you needed to validate fittings on your CCOL where would you look?

A

Dc books

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What book contains step by step procedures for handling casualties?

A

Repair party Manual(RPM)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What book is used for combating fires in Main Spaces?

A

Main Space Fire Doctrine

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

If you need to keep a fitting open for an extended period of time what do you do?

A

Log it in the Material Conditions Violation section of the Closure log

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How long can you keep it open?

A

Not longer then 24 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Fittings you cannot secure are logged where?

A

OOC log (Out of Commission log)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Who maintains the closure log

A

EWS inport DCWS underway

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Who reviews the closure log?

A

FM, DUTY FM, ADCA, DCA, EDO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Name one side of the fire tetrahedron?

A

Oxygen, Fuel, Heal, uninhibited chain reaction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Describe Classes of Fire

A

A(Leaves Ashes) B (HAZMAT,Fuel) C (electrical) D (Combustible metals)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

What is the flashpoint of JP-5

A

140 Degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

4 Stages of fire?

A

Growth, Flashover, Fully developed and Decay

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

How many repair lockers do we have?

A

10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Name repair lockers?

A

2ND deck (2,3,4,5) 1st Deck(1F,1B,1A) 03 (7F,7B,7A)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Which repair lockers respond to main space fires?

A

Repair 4-5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

What do you use to inventory the kits in repair lockers?

A

AEL allowance equipage list

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

PKP comes in 2 sizes, what are they?

A

18, 27

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
PKP?
Potassium bicarbonate
26
What is effective range of a CO2 extinguisher
4-6 feet
27
In continuous operation, how long does the 15-pound CO2 extinguisher last?
40 seconds
28
Before you squeeze the lever to release the CO2, What should you do?
Ground the cylinder to the deck, Avoid static shock
29
How does CO2 extinguish a fire?
It reduces the concentration of oxygen in the air to the point where combustion stops.
30
What are the portable AFFF bottles used for?
Small grease and small class 'B' fires
31
What is the distance of a portable AFFF bottle?
15 ft and decreases with use
32
How much AFFF is in the bottle?
2 Gallons
33
What are the best woods to use for shoring, plugs and wedges?
Douglas fur and yellow pine
34
why do we use this type of wood?
it expands as it absorbs water
35
2 sizes of metal shores?
3-5 feet 6-11 feet
36
What is the vertical load strength of a 3 foot to 5 foot metal shore?
3 ft - 20,000 Lb , 5 ft - 12,000
37
What is the vertical load strength of a 6-11 ft metal shore?
6 ft 20,000 lb , 11 ft - 6000 lb
38
Name 3 types of shoring
I(Direct Pressure), K (Triangulation perpendicular), H (no deck anchorage)
39
What is the strongest shoring?
I type
40
What is the weakest shoring?
H type
41
How many types of pipe patches are there?
4
42
What are the type of pipe patches?
Soft, Banding, Ewarp, Jubilee
43
Which hold up to 100 PSI only?
Jubilee
44
What is the max temperature on a pipe you can apply EWARP?
300 Degrees
45
What is the Max PSI for Banding, Soft, Ewarp
150 PSI
46
What does NIFTI stand for?
Naval Firefighting Thermal Imager
47
What powers the Nifti?
10 AA batteries
48
Is the NIMH battery pack rechargable?
yes
49
How do you know the NIFTI is fully charged
10 bars on the bottom left corner
50
Name 5 kits found in a repair locker?
``` Investigator Electrician Comms Pipe patching Shoring ```
51
what does PECU stand for?
Portable Exothermic Cutting Unit
52
Where are they located?
Repair lockers
53
Who operates them?
Access/Overhaul person
54
What are the cutting rods of PECU made of?
Carbon Steel
55
What size of battery does the PECU use?
12 volt
56
What are the two types of portable eductors?
Stype and Peri jet
57
What is the primary use of eductors?
to remove Greasy, Oily and contaminated water
58
What is primary use of the P-100?
firefighting/dewatering
59
How many P-100 onboard?
2
60
Where are they?
HB1 STBD side MOORING RM | HB2 ADML Pway under the ladder
61
What cools the P-100 while its being used?
AIR
62
What is the maximum lift that a P-100 pump can take suction?
20 Feet
63
What type of fuel does the P-100 use?
JP-5
64
ESP?
Electrical submersible Pump
65
Submersible pumps are not designed for pumping what types of liquids?
Gasoline, Heavy Oils, or hot water
66
What is the maximum static head for the ESP?
70'
67
When using EPS in tandem, which pump do you start first?
The bottom one
68
Ram Fan?
De smoke spaces containing explosive gases
69
What powers the RAM fan?
Fire main
70
what safety precautions must be followed prior to energizing the ram fan?
Ground it
71
What maximum number of trunks can you put on the suction side?
3
72
Ram fan hoses on the suction side how are they connected?
Latching clamps on the ends of the trunks
73
How many cubic feet per minute will it move?
2000
74
Where can you use the Box Fan for desmoking operations?
spaces adjacent to weatherdeck/hanger bay areas
75
what powers the box fan?
Electricity
76
how much air will it move?
3200 CFM
77
Who is in charge of a repair locker during a casualty?
locker leader
78
who is responsible for handling electrical damage?
repair electrician
79
Who is overall in charge of a casualty inside the effected space?
team leader
80
Who caries the NFTI?
Team leader
81
How long will the OCENCO EEBD last during use?
10 minutes
82
Who wears a 30 minute bottle/45 minute SCBA pack?
30 Investigator, Boundary men, Scene leader | 45 team leader and hose team
83
What percent of air do you have left on your scba when the vibra-alert goes off?
25%
84
what are the 2 types of alarms on the SCBA when your air is low?
bell and the vibrant alarm
85
What are the SCBA bottles Made of?
Carbon Fiber
86
What should you do once you take out an SCBA pack prior ot use?
Ensure that it is not below 4000 PSI
87
The nozzle has 3 positions on it what are they?
Solid stream(Over haul), High velocity(Fire fighting), Low velocity(cooling and relief) and flush.
88
Which boundary should be set the fastest during a fire?
Above
89
Who determines a space is safe to enter without breathing protection after a fire?
DCA(at sea)/EDO inport
90
What person on the fire party conducts atmospheric testing?
Fire marshal/ Gas Free Engineer
91
What are the four principles of investigation?
thoroughly, cautiously, report, repeat
92
Air sucking in the test fitting indicates what kind of damage?
fire
93
Air escaping the test fitting indicates what kind of damage?
flooding
94
APC stands for?
Aqueous Potassium Carbonate
95
What is the APC system used for?
Protection for galley deep fat and doughnut fryers and their exhaust system
96
How does APC extinguish a fire?
Combines with the hot cooking oil to cut the oxygen out
97
Where can you find APC?
Galley
98
How many halon boards do we have?
9
99
What activates the halon board
fully pull the activation lever on the 5lb c02 bottle
100
what does 30 sec time delay mean?
unmanned space
101
Name on space where we have a halon board?
FWD/AFT EDG, Pump room 2 and 3, Shaft alley
102
Lights on board Halon
White : power avaiable Amber : Halon Activated Red : Halon discharge Green : vent damper
103
How many C02 fixed flooding systems do we have?
4
104
How do you activate c02 fix flooding?
Break glass pull T shaped handle until you see red on cable
105
Name one space the CO2 fix flooding can be found?
Hazmat storerooms
106
How many recharge stations do we have?
8
107
Name one recharge station?
1b(2), 1A, 1F, 2, 3, 7B, 7F
108
If we lose HP air, what do we use to fill the SCBA bottles?
EBAC (Emergency breathing air compressor)
109
How many EBAC's do we have?
2
110
Name the location of one?
1 forward STBD side, 2nd aft next to the jet shop
111
what is the purpose of list control?
To correct list, so planes can land
112
How many list control tanks do we have?
10
113
How many list control pumps?
2
114
How many places can you operate list control?
2 MCMS in DCC and locally in 4a shaft alley
115
What type of water is in the list control tanks?
Potable water
116
where are the list control pumps located?
4A shaft alley
117
What is the GPM for list control pumps
1800 GPM
118
who operates list control
DCWS
119
What 2 list control tanks can hold the most?
113&165
120
What do we use to determine the list?
Clinometer
121
What type of firemain do we have?
Composite loop
122
How many fire pumps do we have?
23 19 electrical, 4 steam
123
If there is a rupture in the firemain how do you keep it active in that section of the loop?
Rig a 2 1/2 "jumper hose between the 2 closest fire stations by removing the y gate
124
How many drainage eductors do we have?
13
125
How do you operate the drainage system to pump over the side
discharge valve, firemain valve, suction valve
126
how do you secure the drainage system over the side?
suction valve, firemain valve, discharge valve
127
What is the purpose of main drainage?
Pump oil waste or water out of the bilges
128
How many HICAP AFF stations do we have?
20
129
collectively, where are they located?
2nd deck
130
How many mixing stations do we have?
21
131
Where are they located?
on the 03 level
132
What so special about 21?
bomb farm
133
What are the tanks made of?
90/10 copper nickle alloy
134
how much AFFF is in the tanks?
600 gallons
135
how many AFFF stations have balance pumps?
16
136
how many AFFF have injection pumps?
20
137
which stations are injection pump only?
1,2,11,12
138
What is the mixing ration for Firemain and AFFF?
94%, 6%
139
What is the GPM for the injection pump?
60 GPM
140
What is the GPM for the BPP?
65 GPM
141
What is the pancake valve?
Regulates AFFF & Firemain
142
what must you have to ensure the AFFF station will operate?
firemain pressure
143
What is the minimum to maximum firemain pressure needed for AFFF?
125-170
144
SOPV
Energize the Station Solinode operate pilot valve
145
How many volts in the SOPV?
440V
146
How many reserve tanks do we have?
2
147
How much AFFF concentrate is in the transfer tank?
3600 gallons
148
Location of AFFF reserve tanks
HB1 PORT HB3 STBD
149
Reserve pump locations?
6,13
150
What is the GPM for the reserve pumps?
360 gpm
151
How can you activate the reserve station?
remotely and locally
152
Where can it be activated from?
Bridge panel, Pri fly Panel, Hose reels in the catwalks, Hanger bay sprinklers, Hose reels in the hangar bay, Weapons Elecators, Main Space hose reels, 2nd deck hose reels, Bilge and over head sprinklers
153
How many sound powered phone circuits are there?
5
154
What circuit links DC central to Repair lockers
2JZ
155
Primary use of communication from the locker to the scene?
Hydra
156
What is used to keep a hard copy record of events of a casualty
Message blanks and DC charts
157
How do we plot damage?
DCAMS and Dc charts
158
What does a circle on a message blank mean?
casualty contained
159
What is MPE?
Maximum permissible exposure
160
Who sets MPE?
CO
161
What does MOPP stand for?
Mission Oriented Protective Posture
162
What is the primary protection during Chemical, Biological and Radiological attack?
MCU-2P Gas Mask
163
What type of threads does the C-2 canister have?
NATO
164
What does ACPG stand for?
Advance Chemical Protective Garment
165
Don/Doff
Don put on Doff Remove
166
Remove ACPG smock?
Stage 1
167
what stage do you remove gloves and liners?
Stage 3
168
What is the purpose of the M-256a1 kit?
Used to detect Nerve, Blood, Blister in vapor form?
169
What does RSDL stand for?
Reactive Skin Decontamination lotion
170
Waht is RSDL for?
Decontaminate area of the skin
171
The kit contains how many pouches and what color are they?
3. color is green. blue is for training
172
How long must RSDL remain on the skin after applied?
2 Minutes
173
What color does M-9 paper turn when agent is present?
Red
174
At what MOPP level is M-8 paper posted?
Mopp level 2
175
How many MOPP levels?
5
176
What MOPP level are we we at right now?
1
177
MOPP levels?
0,1,2,3,4
178
IPDS?
Improved Point Detection System
179
CDU
Control Display Unit in central
180
RDU?
Remoate display unit bridge
181
Difference between CDU and RDU?
Bridge doesn't have controls just the one in central
182
what type of system is IPDS?
FIxed
183
What does it detect?
Nerve (g and H) series and blister
184
What is HTH
High test hypochlorite
185
How many CCA's do we have?
2 (HB1,HB3)
186
How many DS do we have?
4, Forward by REP2 Male berthing, 2 midship (Male weapons berthing, Female Chiefs Head) 1 AFT Reactor Male berthing
187
Repair 7F
03-10-2-Q
188
Repair 7B
03 ATO SHACK
189
Repair 7A
03-220-9Q
190
Repair 1F
1-69-2-Q
191
Repair 1B
1-143-2-Q
192
Repair 1A
1-225-5-Q
193
Repair 2
2-34-2-Q
194
Repair 4
2-99-2-Q
195
Repair 5
2-160-2-Q
196
Repair 3
2-220-9-Q