Fa Flashcards

1
Q

Two types of panel that are used ?

A

Addressable and conventional

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

A device from another protection system that is actuated from the fire alarm is?

A

Ancillary device

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Two types of smoke detectors

A

Photo electric and ionization.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Bell or horn is an example of

A

Notification cct

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

4 devices that would connected to an initiating cct are ?

A

Heat/smoke detector
Pull station/flow switch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

A device used to remotely display signals from a FA panel is known as

A

Annunciator

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

3 examples of ancillary devices

A

Door mag
HVAC shutdown
Elevator shut down

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

An initiation cct that leaves the fa panel and terminates at the end of line resistor would be ?

A

Class b cct

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

A cct that leaves the FACP connects to remote devices and returns to FACP would be ?

A

Class A cct

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Device used with an addressable FA system that will disconnect a portion of the system when a fault occurs is a?

A

ISO module

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

An electrical fire would be an example of what class ?

A

Class c

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

A ground fault or or open on a cct will be indicated by a ?

A

Trouble signal at the FACP

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Two types of heat detectors are

A

Rate of rise and fixed temp

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Three devices used in conjunction with the sprinkler system would be ?

A

Flow switch
Gate valve
Pressure switch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Activation of a flow switch would cause what in the FACP?

A

Alarm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Removing the cover of a flow switch activating the tamper cover switch would be indicated as what in the FACP

A

Trouble

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What must be observed when installing devices addressable fire alarm system ?

A

Polarity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

To control an ancilliary device from from an addressable what must be installed ?

A

Relay control module

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

To control an ancilliary device from a conventional system the ancilliary device must be hardwired back to a contact in the ?

A

Fa panel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

A fire alarm system that initiates an alert signal that will be followed by an alarm signal within 5 min if not acknowledged is a ?

A

2 stage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

What is the purpose of a fa system

A

To protect life and property

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

What devices are used to warn building occupants of a fire

A

Notification appliances

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

What notification appliances is used to warn hearing impaired people ?

A

Strobes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

What notification appliances are audible ?

A

Horns, bells, sirens

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
What type of device is used to activate the FA system when abnormal conditions occur
Initiation devices
26
List 5 initiating devices devices and list if they are manual or automatic
Pull station-manual Heat detector- auto Smoke detector -auto Gate valve - manual Pressure switch-auto Flow switch -auto
27
What is an ancillary device and list 3
A device or system operated from the FA PANEL doormag Fan shutdown Elevators
28
Why are notification appliances supervised and are they polarity sensitive
To insure no device can be disconnected from cct Yes they are polarity sensitive
29
What the main advantage of an addressable system over conventional?
Has exact location on devices instead of zones( more accurate )
30
Describe the installation of class b cct compared to class a cct
Class b cct leaves panel and terminated at eol Class a cct leaves panel and comes back to the panel
31
What are the 3 different states of a FACP
Normal alarm trouble
32
What devices are connected to monitoring zones in FACP
Gate valve and pressure switch
33
What device is used with an addressable system to control ancillary equipment
Relay control module (RCM)
34
Which class of fire is wood ?
class a
35
What class is flammable liquid/gas
Class b
36
What class is combustible metal
Class d
37
What class is cooking under for a fire ?
Class k
38
What class of fire is electrical
Class c
39
What’s the diffence between single stage and two stage fa system?
Single goes right into alarm two stage give you some time to clear the false before it goes into alarm
40
What is minimum clearance from the corner of a ceiling that a smoke detector can be installed
6”
41
What is the purpose of an iso module
It disconnected a portion of the doc cct
42
What are 4 stages of fire
Incipient Smouldering Flame Heat
43
Which cct contains an end of line resistor
Class b
44
What determines the spacing of heat detectors
Manufactures info
45
What type of smoke detectors is better at detecting a wider variety of smoke types ranging from invisible to black
Ionization
46
What is the most common type of suppression system
Wet sprinkler
47
Which type of extinguishing system can endanger life and will have a delay/warning before it activates ?
Co2- halon
48
Indicate what condition would indicated at the FACP for a wire coming off the terminal of a heat detector
Trouble
49
Indicate what condition would indicated at the FACP for the positive wire touching the metal conduit
Trouble or ground fault
50
Indicate what condition would be indicated at the FACP for pull station
Alarm
51
Indicate what condition would be indicated at the FACP for a flow switch
Alarm
52
Indicate what condition would be indicated at the FACP for a gate valve
Trouble /supervisory
53
Indicate what condition would be indicated at the FACP for cutting the active initiating cct of a conventional system with side cutter
Alarm
54
Indicate what condition would be indicated at the FACP for reversing the polarity on a smoke detector
Trouble
55
Indicate what condition would be indicated at the FACP for removing the cover of a flow switch that has a tamper switch
Trouble
56
What type of smoke detector would have the least nuisance trippin near a kitchen ?
Photo electric
57
3 parts of fire triangle
Heat oxygen fuel
58
In a conventional fire alarm system what device is used to provide cct supervision ?
EOL
59
What signal condition is caused in a two stage system when initiating device is activated ?
Alert signal
60
In a conventional fire alarm system which ccts require an EOL resistor ?
Initiating cct and notification appliance
61
In a conventional system which devices are polarity sensitive
Smoke detectors
62
In an addressable system which devices are polarity sensitive
All of them ….. notification appliances modules and initiating devices
63
List 3 types of sprinkler tree devices and the condition each device will initiate through fa panel
Flow switch -alarm Tamper switch-supervisory Low pressure switch -supervisory
64
What type of cable connector must be used for linear heat detector cable ?
Strain relief connector
65
Reason for an EOL resistor in a fa system
Provide supervision of system
66
List 3 types of linear heat detector
Stand digital Confirmed temp initiation Fiber optic
67
How shall a stand linear heat detector be tested ?
Measure loop resistance
68
What type of addressable module can be used to interconnect a conventional cct/device to a addressable system
Monitoring module