Fire Tech Week 1 Flashcards Preview

Study Grp Week 1: Guide to Co. Journal, SCBA, AUC 202, 220, 323, 346,TB-apparatus C-2,L-7,P-3 > Fire Tech Week 1 > Flashcards

Flashcards in Fire Tech Week 1 Deck (15)
Loading flashcards...
1

This is a test question. Is rob clappi really gay ?

Hell Yes

2

List the layout of the Company Journal for Chiefs Visits and Drill Marks

Chiefs visits run pages 500 to 498. Company Drill Marks run pages 497 to 495.
Guide to Company Journal 3.1 3.2

3

Translate the following Flagging Column Entries:
CV COM DF DSP EE EI
PR SP VIS

CV - Chiefs visit to Qtrs Com - Complaints
DF - Diesel Fuel DSP- Discipline (Charges)
EE - Entries Examined EI - Exchange of Info
PR - Property (lost, damaged) SP- Special Entries
VIS - Visit by Non-Member

Guide Co. Journal sec 5

4

The Flagging Column is how many inches to the left of the existing red column in the Company Journal?

3/8"

Guide to Co. Journal Sec 3.4

5

T or F: As per AUC 202, Upon arrival of the Testing Unit the House Watchman should make an announcement for all members to report to the apparatus floor.

False

AUC 202 6.4.3

6

If your SCBA malfunctions or becomes depleted of air, where should you remove your face piece?

Face piece is removed upon exiting the contaminated area.
AUC 220 Sec 2.4

7

A Probationary FF should maintain their notebook for what time period?

One year following assignment to their company.

8

The Electronic BF4 (EBF-4) is linked to which databases?

HRIS Database
Spare Radio List
CADS
it is NOT linked with masks

AUC 346 Sec 1.1

9

Who is listed on the Preliminary EBF-4?

Members for that tour plus any members awaiting relief.

10

How long should the Company Journal be retained?

20 Years

11

1- Because of the many variables affecting a hydrants capacity, the intake pressure gauge should be continually monitored once water is flowing (Residual Pressure) to determine if the hydrants capacity will be able to support additional lines. When residual pressure drops below _____ psi on the intake pressure gauge, augmentation will be required

15

12

what position is to be utilized as a standard operating procedure for the transfer valve on an engine? ( the position that we keep it in for everyday normal use

Volume

13

When arriving at second or greater alarms the ________connection should be used if available

10’ hard suction

14

The Load capacity at the tip of a 100′ Aerial Ladder Apparatus Varies from______ Depending upon on the degree of elevation

250-750 lbs

15

when the PRO - PRESSURE GOVERNOR on an engine is Malfunctioning an officer would be correct if he knew that?

The company is OOS