FLSD On Site Flashcards

(59 cards)

1
Q

Building Identification Number

A

4457326

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Address

A

135-33 38th Ave

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Construction Class

A

Class IC, Type IB, Non Combustible

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Hotel Floors

A

Basement to 8th Floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Number of Rooms

A

32

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Building Population during Day

A

45

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Building Population during Night

A

54

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Building Population during Weekend

A

66

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Stories Above Grade

A

8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Stores Below Grade

A

1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Height of Building

A

83 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Ground Level Floor Area

A

1350 sq ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Ground Level Dimensions

A

25ft x 58ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Type of Construction

A

Steel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Truss Construction Roof or Floors

A

N/A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Horizontal Connections

A

N/A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Roof Setback Levels

A

Roof to Fl-8 roof

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Exit Stairway A

A

Basement to 8th Floor, Not Pressurized, Has Standpipes, Setback

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Exit Stairway B

A

Basement to 8th Floor, Not Pressurized, Has Standpipes, Setback

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Re-Entry Floors

A

Every floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Access / Convenience Stair Located Between Floors

A

Cellar to 1st Floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Roof Access Provided By Stairwells

A

Stair D

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Fire Tower

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Elevator A

A

1 Car, Serves Basement to 8th Floor

25
Freight Elevator Banks
N/A
26
Sky Lobby
No
27
HVAC Zones
Guest rooms are heated and cooled with individual wall units, located in each room. No HVAC for the cooridors
28
Building Management System
No
29
Smoke Management System
Yes, with Purge, MANUAL
30
Location of Mechanical Room
There is a mechanical room on each floor, from the Cellar to Fl8
31
Fuel Oil Tank Locations
N/A
32
Roof Storage
N/A
33
Standpipe Location(s)
Scissor Stairs, so the standpipes alternate
34
Stair A: Floors 1, 3, 5, 7
35
Stair B: Floors 2, 4, 6, 8
36
Standpipe Isolation Valve Location
Basement Storage, Cellar Meter Room
37
FD Connections Location
38th Ave, Ext, Combined (Sprinkler / Standpipe)
38
Building Fully Sprinklered
Yes
39
Pressure Reducing Valve Floor Location(s)
N/A
40
Pump Types and Locations
Water Pumps in Basement Storage/Cellar Meter Room
41
Non-water Fire Extinguishing System
N/A
42
Natural Gas Service
Yes
43
Electric Service
Yes
44
Steam Service
N/A
45
Gas Shutoff Location
Cellar Meter Room
46
Electric Service Location
Cellar Meter Room
47
System Water Source
City Main and FDNY Connection, Emergency Gravity Tank
48
Cell Tower Location
N/A
49
Energy Storage System
N/A
50
Uninterrupted Power Systems
N/A
51
Communication for FDNY
3 Radios at Front Desk
52
Number of Radios for FDNY Use
3
53
24 Hour Location
Front Desk
54
Fire Safety Director
Peter Yau
55
Work Number
7184613888
56
FSD Emergency Number
9177706883
57
Building Engineer
N/A
58
Managing Agent
Sean Hu
59
Manager Emergency Number
6468359605