Flt Deck Prep Flashcards Preview

AK Limitations > Flt Deck Prep > Flashcards

Flashcards in Flt Deck Prep Deck (16):
1

FDAS TEST: How is it checked? When does it need to be done?

FDAS Switch NORM. Door OPEN
FLT DK Door switch AUTO
access code + ENT
-double chime
-auto unlock illuminates
FLT DK Door switch DENY
-auto unlock light extinguishes
FDAS switch OFF
-lock fail illuminates
FDAS switch NORM
(Inside flight deck)
Close door ensure locks
FDAS - OFF

Only on the first flight


2

When do you have to address PBE with replacement before takeoff?

Both seals broken and pink spot.
(Broken seals and a baby girl)😳

3

Fault/inop detection test. What should you see during the test?

OVHT/DET switches - NORMAL
TEST switch - FAULT INOP
VERIFY (2) master cautions
OVHT/DET Annunciator
FAULT light
APU DET INOP light

4

What happens if during the fire protection FAULT/INOP test you notice the FAULT light fails to illuminate?

The fault monitoring system has failed

5

What should you do if you notice during the fire protection FAULT/INOP test that the APU DET fails to illuminate?

DO NOT OPERATE THE APU

6

OVHT/FIRE detection test. What should you see or hear during the test?

Test switch - OVHT/FIRE
Warning Bells
(2) Master Warning Lights
(2) Master caution lights
OVHT/DET annunciator illuminate

Master Fire WARN - push
-verify bell and master fire cancel
-verify
---ENG1/APU/ENG2 fire illuminate
---ENG1 and ENG2 OVHT lights illuminate
A/C power - Main Wheel Well fire illuminate
Verify FAULT light and APU DET INOP stay extinguished
-if fault light illuminates a detection loop is inoperative.

7

CARGO FIRE/SMOKE detection test. What should you see or hear during the test?

Detector Select -Norm/both
Test switch -push
-verify
Fire Bell
(2)Master fire Warning
PUSH Master Warning LIGHT
-verify
Fire bell ceases
Master Warning lights extinguish
Cargo Fire (FWD/AFT) warning and EXT are illuminated
-verify
Detector fault remains extinguished

8

Prior to APU start what should you confirm?

APU bleed switch -OFF
PACK switches- OFF
#1 AFT fuel pump- ON

9

What should you see when you turn on GEN #1 bus switch (apu running)?

Both Transfer Bus Off lights- extinguish
No. 1 Source off light - extinguish

10

What should you see when you turn on GEN #2 bus switch (apu running)?

No. 2 Source off light - extinguish
BAT Discharge Light- extinguish

11

Main wheel well fire warning test. What should you see or hear during the test?

TEST switch - hold to OVHT/FIRE
Verify
-fire bell
-(2) master warnings
-(2) master cautions
-OVHT/DET annunciator illuminates
PUSH MASTER WARNING
Verify
-Bell cancels
-(2) Master Warning lights extinguish
-Wheel Well Fire light illuminated

12

What should you hear when you press the mach airspeed warning?

Clacker

13

What should you see when stall warning is pushed?

Control column vibration

-The stall warning test requires AC transfer busses be powered for 4 mins.

14

When you connect AC POWER what lights should extinguish?

Transfer Bus Off, Source Off, Bat Discharge, TR Unit, ELEC, Standby power off lights
ELEC
Standby power off
Source off
Transfer bus off
Unit TR
Discharge (battery)

15

What is the verbatim announcement to Flight Attendants prior (minimum of 2 mins prior) to Takeoff?

Flight Attendants should now be seated for Takeoff

16

What are the engine call outs and visual ques?

3.050 ph6