friction loss values 2 1/2" and 4" Flashcards

(38 cards)

1
Q

80 GPM 2 1/2

A

2 PSI PER 100’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

125 GPM 2 1/2

A

4 PSI PER 100’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

200 GPM 2 1/2 (FDC)

A

10 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

250 GPM 2 1/2

A

15 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

300 GPM 2 1/2

A

20 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

325 GPM 2 1/2

A

25 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

350 GPM 2 1/2

A

28 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

400 GPM 2 1/2

A

36 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

500 GPM 2 1/2

A

55 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

530 GPM 2 1/2 (stookie)

A

60 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

550 GPM 2 1/2

A

66 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

600 GPM 2 1/2

A

78 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

650 GPM 2 1/2

A

91 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

660 GPM 2 1/2

A

94 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

700 GPM 2 1/2

A

105 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

750 GPM 2 1/2

17
Q

800 GPM 2 1/2

18
Q

855 GPM 2 1/2

19
Q

1000 GPM 2 1/2

20
Q

1060 GPM 2 1/2

21
Q

200 GPM 4”

22
Q

250 GPM 4”

23
Q

300 GPM 4”

24
Q

325 GPM 4”

25
350 GPM 4" (portable monitor)
3 PSI
26
400 GPM 4"
5 PSI
27
500 GPM 4" (portable monitor)
5 PSI
28
530 GPM 4"
5 PSI
29
550 GPM 4"
6 PSI
30
600 GPM 4" (1 1/2" ladder pipe)
7 PSI
31
650 GPM 4"
8 PSI
32
660 GPM 4" (hydro foam)
9 PSI
33
700 GPM 4"
10 PSI
34
750 GPM 4" (portable monitor)
11 PSI
35
800 GPM 4" (1 3/4" ladder pipe)
12 PSI
36
855 GPM 4"
14 PSI
37
1000 GPM 4" (2" ladder pipe)
19 PSI
38
1060 GPM 4"
20 PSI