1
Q

What is the minimum distance required from the shower outlet for hobless removal?

A

1500mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What typically requires a full renovation in bathroom construction?

A

Hob removal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is a potential solution to reduce water leaking into the home when the shower recess is next to a door?

A

A weighted curtain with a screen panel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is a challenge when installing rails in a steel frame house?

A

The installation of rails into steel ‘studs’ do not provide the sufficient SWL. Therefore, work can only be done if a stud can be “blocked” out from the other side of the wall (can’t be done if other side of wall are tiles such as a kitchen or outdoors)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What condition must be met to install into a steel frame?

A

Can block it behind

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Is a HHSH peg or slider more appropriate for majority of clients?

A

A peg as it is easier for people with fine motor difficulties and requires less strength

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the typical distance for a stud from another stud?

A

450 or 600mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

True or False: You can remove the vertical shower screen frame attached to the wall for better clearance.

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What are brick patterned tiles?
Why are they a problem?

A

Tiles that line up in alternate rows such as bricks. As there is no straight vertical line to cut down, any work that may require bricks to be cut out, will require re-waterproofing and thus cost more.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Does a peg need to be installed into a stud?

A

No it does not as it is not redesigned for weight bearing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How far can an underbracket extend past a stud?

A

250mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is recommended on OT reports as per Aaron?

A

Alternate options such as cheaper alternatives

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What can be a possibility with assuring easier opening of an outswing door when recommending a landing?

A

A wider landing so that the client can step to the side when opening the door

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Are vertical or horizontal grab rails easier to install in a shower recess?

A

Horizontal is easier to install into studs. Vertical grab rails may become non-functional for the client if the stud is too far from the recommended position.
Verticals may be able to be installed towards the edge of the shower

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Where are there typically studs in the shower recess?

A

Corner of the shower, middle of the shower and just outside of the shower recess

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Are there bariatric rails available?

A

No, not yet. The rails are available, however a proven fixture type has not been found.

17
Q

Is there an option for the bottom of the handrail if there is not much clearance space for a lead in?

A

Yes, you can have the bottom of the rail curved towards itself, providing the client with initial contact prior to the first step