GTGs Flashcards
(7 cards)
1
Q
GTG Rating
A
3000 KW at 450 VAC, 4800 Amps, 60 Hz, 3 phase, 0.8 power factor
2
Q
ZEDS
A
Zonal Electrical Distribution System
3
Q
Electrical distribution system components
A
- 3 GTGs
- 3 Switchboards
- 23 Load Centers
- 10 Lighting Load Centers (LTG LCs)
- Power Panels (PPs)
- Power Distribution Boxes (PDBs)
- Manual or Auto. Bus Transfer (MBT/ABT), and Static Automatic Bus Transfer units (SABT)
- Lighting Distribution Panels
- Lightin Distribution Boxes
- Power and lighting Transformers
- Casualty Power distribution system
4
Q
ZEDS
Zones
A
1-5 Fwd –> Aft
6 –> 01 level up
5
Q
Start Permissives for the GTG
A
- Cooling fan running or in auto
- RPM <600 for Bleed Air starts
- RPM <1215 for RIMSS start
- No shutdowns active or illuminated
- Not in Input/Output (I/O) mode
- Not motoring
- Hard Wire Fuel Trip (HWFT) off
6
Q
Lubrication oil for the GTG
A
23699
7
Q
Stages that Bleed Air is extracted from
A
5th, 10th, and 14th
5 &10: Are open to the atmosphere during start to prevent stalling of the compressor
14: Vented to the atmosphere using diffuser valves
- Primary source of bleed air for the ship