High Rise Flashcards

1
Q

The peekaboo feature is not available during independent control

A

true

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

*Independant control should only be used of firefighter control is not available and at the discretion of the officer

A

true

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What happens in Phase 1 (emergency recall)

A

all elevators in that shaft return to the lobby and all their doors open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What happens in phase II

A

The difference is how the elevator is opened, press and hold the open until the door is fully opened

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Do not rely on the nameplate for emergency recall key

A

it can be jostled out of place

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the firefighter helmet light for

A

For the elevator shaft, if it is flashing the elvator is not safe to use

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The firefighter control switch inside the elevator will only function if the Phase I controls have been activated

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What coupling is on the outside of the high rise packs?

A

Female

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Municpal water supplies enough water pressure up to how many floors without a pump

A

3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What are the next two zones

A

3rd-13th and 13 +

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How many kpa is the fire pump set to for the top floor

A

700 kpa

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How many floors below suspected fire floor should you stop

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What floor is the stanpipe made on

A

one below

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What does CFD consider a highrise?

A

Any building 6 or more

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

If two or more alarms are showing on a panel there is a higher chance of a working incident

A

true

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

How many floors are allowed before a crossover floor must exist

A

5

17
Q

A minimum of 3 people are required for the first investigating team

A

and one left as elevator control person

18
Q

If phase one cannot be established do not use elevators

A

true

19
Q

Occupants may still use elevators until phase one is manually activated by FF

A

true

20
Q

Independent control gives full control gives full control but without

A

peekaboo or call cancel features

21
Q

Fires can double in size every 30-60 seconds

A

true

22
Q

Stairwells are generally designated by CFD as

A

Fire attack and Evacuation

23
Q

With scissor stairwells the exit/entry should be the same on every

A

second floor

24
Q

In all working incidents the top floor should be checked for the prescence of smoke

A

true

25
Q

Evacuation should concentrate on the highest risk

A

2 floors above and 2 floors below the fire floor

26
Q

Staging floor is usually

A

2 floors below the fire floor

27
Q

Officers are to submit their green fire passes to the interior staging manager

A

true

28
Q