High Rise Fireproof MD’s Chap2 Flashcards

(56 cards)

1
Q

All newly constructed, HRFPMD built under the ——— building code are fully sprinkler throughout the structure.
1.2 NEW **

A

2008
75’ or more in height

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

HRFPMD’s Are well constructed and maintained, 75 feet or more in height, but sometimes has exposure problems.
1.4

A

False
Rarely exposure problems

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

HRFPMD’s
Newer buildings use ——— —— in the interior construction
1.6

A

Gypsum board (sheetrock)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

HRFPMD’s
Whenever ———- stairwells or encountered, doors to any and all evacuation stairs must be maintained closed on the fire floor.
2.4

A

Enclosed stairwells

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

HRFPMD’s
Prior to advancing to the reported fire floor members must gather information from the ———- or ——— below if ——— stairs are present. 2.5.

A

Floor below or two floors below

Scissor stairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

HRFPMD’s
General operations
Determine three things serving the fire floor? 2.5.1.

A

Location
Letter designation
Number of stairways serving fire floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

HRFPMD’s
Prior to the designation of the ——-stairway, all members must access the fire floor from the same stairway.
2.5.2

A

Attack stairway

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

HRFPMD’s
Horizontal ventilation of the fire apartment should be limited to and controlled by ———— ?

All all ventilation must be strictly limited and controlled by?

Vertical vent will only be performed on the direction of?
3.1

A

Ladder company officer operating in the fire apartment
IC
IC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

HRFPMD’s
The stack effect is influenced by
4 things?
3.2.2

A

Height of building
Temperature differential between outside and inside temperatures.
The HORIZONTAL air exchange on each floor.
Wind

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

HRFPMD’s
Wind: a major factor for smoke movement within a structure. Wind pressures external to the building. Create pressure within the structure on both the. —— and —— . 3.2.3.

A

Windward Side (high pressure)
And
Leeward side (low pressure)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

HRFPMD’s
Generally, when moving across a roof level will cause a ——- pressure to be created, which can increase ———- stack effect inside the stairwell.
Regardless of which side of the building, the wind is impacted or the position of the bulkhead on the roof. 3.2.3.

A

Lower pressure

Positive stack effect 

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

HRFPMD’s
HVAC are installed most commonly in? 3.2.4.

A

Hotels
and
the hallways of upscale high-rise apartment buildings

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

HRFPMD’s
Like high-rise office building procedures, ventilation of the fire apartment should take place ——— the main body of fire has been controlled.
4.1

A

After

PS The IC shall control, all ventilation other than the fire apartment.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

In some HRFPMD’s there may be windows in the public hallways and stairways. These windows shall not be vented without prior approval of the?
4.3

A

IC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

HRFPMD’s
Stairways other than the ——— stairs may be used for venting the fire floor.
4.4

A

Evacuation stairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

HRFPMD’s
When an elevator not equipped with fireman, service is used, it shall be? 5.1.

A

Returned to the lobby unstaffed. 

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

HRFPMD’s
The —— arriving company shall recall the elevators, whether or not they will be used.
The —— arriving company shall ensure that all elevators are recalled and searched.
5.2

A

First arriving ladder company recalls.

Second arriving later company ensures, recalled and searched. 

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

HRFPMD’s
The doors to the elevator machinery rooms at roof level should not be used for ventilation purposes until the fire is? 5.3.

A

Under control

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

HRFPMD’s
When both the engine and ladder companies arrive together, and only one elevator is available (non-fireman service), who shall go in the elevator? 5.6.

A

Ladder officer with forcible entry team
Engine officer with two firefighters, Nozzle and control with all roll ups lengths and stand up kit shall go up first.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

T/F
HRFPMD’s
If the elevator has fireman service, and no outside operations are indicated, the IV will be operating the elevator. This will dictate reducing the elevator load by one of the engine firefighters 5.6.

A

True
Ladder officer with forcible entry team.
Engine officer with one fireman does not say if it’s gonna be the nozzle or the control of firefighter. With all rolled ups and standpipe kit shall go up.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

HRFPMD’s
When the OV is evolved in an outside operation in the fire is above the —— floor, the elevators will be operated by a member from second ladder and or other members designated by the IC. The IC must ensure that if available at least two elevators will be driven in.
————- by firefighters for the duration of the operation.
5.6.2

A

Above the 7th floor

Fire service phase 2
(it looks like the get rid of the word fireman)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

HRFPMD’s
Some building designs for the more exclusive type of HRFPMD’s have elevators opening directly into ——- or into ———. 5.7.

A

Apartments or into foyers.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

HRFPMD‘S
No stairs or other means of egress are provided from this type of foyer, and these types of elevators should not be used by members. What type of elevators are these? 5.7

A

Elevators opening directly into apartments or into foyers.

24
Q

HRFPMD’S
A service/freight elevator shall not be used until it has been evaluated and declared safe by the use of the ———-? 5.8.

A

Company officer

PS standpipes are usually found in this service stairway.

25
HRFPMD’s When the main body of fire has been controlled, enjoying apartments can be forced for reasons such as? 6.1.1.
High carbon monoxide readings. Severe smoke conditions in public a hallway,
26
HRFPMD’s If it is decided that an apartment door is going to be forced to provide an area of refuge, the door selected must be to an apartment that is? 6.1.3.
Entirely on the same side of the building as the fire apartment.
27
HRFPMD’s The 10-77 signal provides additional units to initially manage a fire and smoke condition. 1-——- ——- fire conditions 2-——— fire on arrival 3-———- smoke on———- floors 4-No more reports of people in difficulty due to ———. 7.2.2
1- wind impacted 2- advanced fire 3- heavy smoke on numerous floors 4- smoke
28
HRFPMD’s The —— and —— shall be assigned to the fire sector with the fire is above the ——- floor. 7.3.
Fast UNIT and CFR engine Above the 6th floor
29
HRFPMD’s At lower floor fires six floor or below the position of the Fast unit, and CFR engine will be determined by the ——-. The Fast unit shall carry ———. 7.3.
IC Set of elevator keys
30
HRFPMD‘s 1st engine company. Variations from stretch and initial hose lines from standpipe outlets on a floor below the fire due to building configurations shall be approved by ——— and entered into CIDS program. 8.1.4.
Division commanders Enter into CIDS
31
T/F HRFPMD’s S 1st engine. Communicate with the ladder company officer to select the attack stairway. The attack stairway need not be the stairway with a standpipe outlet. 8.1.5 B.
True
32
HRFPMD‘s 1st engine. Who gets notified of the designation of the attack stairway? 8.1.5 B
2nd engine and IC
33
HRFPMD’s Control of the fire department entrance door: 1-hoseline can be advanced to? 2- —— will assist with keeping the fire department door closed until there’s water at the nozzle and the hose light is ready to advance into the apartment 3- in most cases, the hose line shall not enter the apartment until the ladder company ——- and ——- for the advancing engine company 8.1.5 C
1-fire apartment entrance door 2-engine officer 3- locates the fire and provide direction
34
HRFPMD’s Apartment door has been left open, public hallway is now considered an extension of the fire area. 1- hose line should be charged before ——— 2- in most cases, hose line shall not enter the public hole until the ladder company locates the ——— and ——- for the advancing engine company. 8.1.5 C
1- exiting the attack stairway 2- fire apartment and provide direction
35
HRFPMD’s Control firefighter will remain at the standpipe outlet throughout the operation, provide orderly and accurate communication and continuity. 8.1.5 6
True
36
HRFPMDS After the fire has been extinguished, the engine company will use what for ventilation of the fire apartment. 8.1.5 E
Fog tip
37
38
HRFPMD’s 2nd engine officer must recognize and request additional assistance from the IC when? 8.2.1
Long and complicated stretches are encountered
39
HRFPMD’S Who is responsible for getting the post Radio 8.2.2
2nd engine company to arrive PS get the post radio from the 1st arriving battalion
40
HRFPMD‘s Who ensures the fire department connection is supplied? 8.2.3 a.
2nd engine (it does not say officer)
41
HRFPMD Second engine gets to post radio and brings it to? 8.2.3.
Standpipe outlet where first hose line is being connected and and establish a communication link.
42
HRFPMD’S Post radio is at the standpipe outlet communication link on the ——- channel between the ——- and ——-. 8.2.3 B
Command channel Fire sector and IC
43
HRFPMD 2nd line may be used to: 1-Back up, the ——- 2-Advance with the —— 3-Operate the ——- nozzle 4-Operate into a breach in ——- —— wall while the 1st ine is protecting the public hallway. 5-Floor above due to ———- via windows or air conditioner sleeves. 6-Operate on the floor above due to extension via ———- or ———-. 8.3.3 C
1- back up 1st line 2- 1st line 3- HI-Rise Nozzle 4- adjoining apartment 5-auto exposure 6- utility voids or steam pipe risers
44
HRFPMD‘s 4th engine one length to pose fire fighter and the standpipe kit report into? 8.4.2
IC at ICP
45
HRFPMD Who is responsible for placing the high-rise nozzle into operation? 8.5.1
5th assigned engine company
46
HRFPMD’s When the 5th assigned engine company is not equipped with a HRN, the officer shall contact the ——— for the identity of the unit carrying the HRN that has already been assigned to the 10-77. 8.5.2
Dispatcher
47
HRFPMD’s CFR engine company which equipment do they bring in 8.6.2
CFR Equipment Forcible entry tools
48
HRFPMD’s Lower floor fire. Similar to other standpipe, equipped buildings , when a hose line is hand stretched from the apparatus into a fireproof MD, the use of 2 1/2 inch hose is NOT mandated. The size of the hoseline stretched 1 3/4 or 2 1/2 will be based on ? 8.7.1
Occupancy and conditions 2 1/2 inch hose is NOT mandated This is true for high rise and low rise fireproof MDs
49
HRFPMD’s 1st ladder is responsible for: Elevator ——- Control of the —— and ——---on the fire floor. 9.1.1.
Elevator recall Attack and evacuation stairway doors on fire floor
50
HRFPMD’s When there are two stairways, Who helps in assisting in determining the attack stairway? 9.1.2 3
1st ladder officer
51
HRFPMD‘s If smoke and or heat condition exist in the public hallway notify the IC. Prior to entering the public hallway, the officers shall get a report on exterior conditions from members operating? 9.1.2. 4 A
Outside the building and the roof firefighter operating on the floor above. If smoke and heat condition is due to wind impact fire, members shall remain in stairwell. Then follow procedures outlined in chapter 5.
52
HRFPMD’s If unable to determine wind impact to fire, the ladder officer and one member of the forceful entry team shall enter the public wall to locate the fire department and control the fire department door. The other member of the interior team will remain at the attack stairwell door on the —— side of the door. 9.1.2. 4B
Hallway side. Ensure the stairwell door remains closed, limiting the flow path and to act as a beacon incase members need to evacuate the hallway. The engine company officer shall be responsible for control and coordination on the stairwell side of the door.
53
HRFPMD’s If operating in the public hall, it is determined to be a wind impacted fire the ————- shall ensure members exit public immediately. 9.1.2. 4C
Ladder company officer
54
HRFPMD’s Do not chalk the door open until? Page 19
Charge hose line is moving into the fire apartment.
55
HRFPMD‘s OV If the fire building does not have fire service elevators, where does the OV go?
Go to the fire floor, team up with your officer and assist in the search of the fire apartment
56
HRFPMD’s Roof firefighter Proceed to the department directly above the Fire via the ? 9.1.4
Attack stairway If the attack stairway is an IDLH area team up with another member prior to proceeding to the floor above.