High rise MT Flashcards

(52 cards)

1
Q

High rise building code requirements started in ____

A

February 1976

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the requirements for buildings to have fire control rooms?

A

Building 75 ft or higher

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The window panes that can be broke are marked with what?

A

Maltase cross or fire helmet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

how far away are hydrants supposed to be from FDC’s

A

100 Feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Doors that separate various occupancies swing what direction?

A

Inward

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Outward opening doors indicate what types of rooms?

A

Electric
telephone
closest rooms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Preference should be given to using risers in?

A

Stairwells

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

what can severely restrict flow on standpipe riser outlets and how do you bypass it?

A

Pressure-reducing valves

Break the L shaped arm that restricts the riser wheel.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Otis Gen 2 use a _____ which allows them to not have a conventional elevator room.

A

Flat belt design/ Belt driven system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

___ Elevators bypass a portion of a building via a blind shaft?

A

Express

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

In____ service the doors will not open until the door open button has been activated.

A

Firemen service.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

____ is used for any system in a high-rise where detection, fire protection, air handling systems, and communications are centralized for the FD use.

A

Fire control room

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Fire phones taken off the hook trigger a notification in the?

A

Fire control room

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What’s a system designed to allow personnel in the fire control room to communicate throughout the building including any tenant space above 1,000 sqft.

A

Public address system.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What are the 3 types of smoke control systems that activate in the presence of an alarm?

A

Stairwell
Corridor
Elevator pressurization

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

If more than ___ floors above the fire contain occupants a ___ should be established with a chief officer in charge.

A

2

Search and evacuation branch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

____ Refers to normal smoke movement without impact from environmental conditions, smoke rising upwards, than migrates back downward

A

Mushrooming

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Natural movement of air within a relatively tightly-sealed building due to the temp. Difference btw the air on the inside and outside of a structure. Smoke will rise until temps balance or stratify. the reverse when outside temp is higher than inside___.

A

Stack effect

Reverse stack effect

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Once fire floor is reached what must be communicated?

A

Fire conditions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Situation report should have?

A

VIT
Volume of fire
Intensity of heat
Temperature seen though the TIC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

If wind driven fire is present, no___ should be performed until directed by command.

A

Horizontal ventilation

22
Q

Contents of a building have a heat release rate can allow a fire to ___

A

double in size every 90 seconds

23
Q

Buildings under construction are required to have a riser?

A

Two floors below the finished floor

24
Q

Personnel must not be committed to the interior for operations if?

A

Concrete work is still underway and the framework is in place and burning

25
Personnel should consider using ___ system when available.
Building communications
26
Command officers should consider requesting a ________ response to supplement the operation.
Rit level 2
27
What building systems must be brought under FD control? EAP
Elevator control Air handler Pump- fire pump
28
First fire chief on scene must establish command, the second due chief will establish___?
Fire attack group supervisor
29
How do you check suspended ceilings?
Physically or TIC
30
Residential fire flow of __ GPM get every __ Square feet. Commercial is 20GPM.
100GPM per 100 sq ft
31
Use a combination of what to keep attached parking garage stairwells clear of smoke?
PPV and garage ventilation system.
32
First due engine should? FWAARRD
``` Floors wind attack stairwell annunciator recall elevators rapid entry keys directory ``` FWAARRD
33
when using elevators in high rise fires what must you do?
Stop at intermediate points and check shaft for water, fire or smoke Stop 2 floors below report fire floor
34
what floor does the fire have to be over to use the elevator?
6
35
How many companies are allowed to ride the elevator together?
2
36
Who should determine the attack stairwell?
Engine officer and officer of first specialty piece
37
Second due engine
water supply and stretch 3'' or greater into the FDC and assist in placing firs hose line, 1 firefighter remain at the stairwell door and officer at standpipe outlet
38
third engine?
Secondary FDC view opposite side floor above fire
39
fourth due engine?
RIT | 1 floor below the fire or outside IDLH for below grade
40
Fifth due engine lobby control assignments
officer and FF unit tracking and recording ( SCBA pressure, crew and times) LB-get with building engineer and building system control ( turn on fire pump and shut down HVAC Driver- Elevator operations
41
Search priority? Residential commercial
fire unit, exit hallways, adjacent and units across the hall | Fire area and floor, floor above, top floor, floors between fire floor and top floor.
42
second due truck shall?
Proceed to floor above the fire and work with 3rd due engine | insure evacuation stairwell is identified and clear of smoke
43
Rescue squad shall?
``` Deploy tag line in attack stairwell forcible entry evacuation assess fire extension assist in movement of 2.5'' handline ```
44
who is the base officer
6th due engine driver
45
what should second alarm or greater units bring?
2 air cylinders and high rise pack
46
where is staging
2 floors below the fire
47
Who will open a window and assess wind conditions
truck or rescue squad operating on the floor above the fire
48
what ventilation is the least desirable option?
vertical vent
49
when should a search and evacuation branch or group be activated?
more then 2 floors above the fire that still contain occupants
50
anticipate air cylinder will last
15-20 mins
51
What is the fire load in general office space, conference area and file area?
7.7 LBS/SQFT General office Conference area is 5.9psf file area is over 16psf
52
what are the effects of cold smoke
is cool and low lying smoke, characterized fires brought under control by sprinkler systems