***Hoist Procedures*** Flashcards Preview

UH-1N > ***Hoist Procedures*** > Flashcards

Flashcards in ***Hoist Procedures*** Deck (9)
Loading flashcards...
1
Q

When should the power available check be accomplished?

A

Prior to hoist operations

2
Q

Where is the hoist power switch located?

A

On the left side of the overhead console panel

3
Q

Where are the hoist circuit breakers located?

A

On the overhead circuit breaker panel

4
Q

How many hoist cable cut switches are there and where are they located?

A

There are two:

  1. The pilot’s is on the center pedestal
  2. Hoist operator’s is mounted on the back of the rescue hoist control panel
5
Q

What is the usable length of the hoist cable?

A

250 feet

6
Q

What is the maximum operating load for the hoist?

A

600 lbs

7
Q

T/F - When pulling the survivor into the helicopter, the easiest method is to turn the survivor’s back to the helicopter and pull in.

A

True

8
Q

What should you do if the hoist OVERTEMP light comes on during hoist operations?

A

Terminate hoist operations as soon as possible, allowing the hoist to cool until the OVERTEMP light extinguishes

9
Q

What is the maximum allowable load on the hoist when the speed mode switch is in the HIGH position?

A

300 lbs