HUSKY 3 Flashcards Preview

Captains test > HUSKY 3 > Flashcards

Flashcards in HUSKY 3 Deck (16):
0

FOAM CONCENTRATES

0.3% 1000GAL
0.5% 600 GALS
1% 300
3% 100 CLASS B FOAM

1

PRIMER

EVACUATES AIR FROM THE FOAM LINE
ONE BUTTON

2

FLUSH

ONLY NEED TO FLUSH THE LINE UNTIL ALL BIBBLES ARE REMOVED

3

WORKING PRESSURES

75-250

4

FOAM PICKUP TUBE

USED TO FILL OR TO SUCTION
ON THE GROUND

5

Percent at 1000 gpm

.3

6

Percent at 300 gpm

1

7

Percent at 100gpm

3

8

Percent of foam at 600 gpm

.5

9

Solid green led

System on

10

Solid red

Valve position error

11

Solid yellow

Priming

12

Flashing green

Injecting foam

13

Flashing yellow

Refilling tank

14

Flashing red

Low foam tank

15

Procedure to refill tank

Battery on
Move handle to draft
Connect hose
Turn valve to to fill
Press Dec% until FIL displayed
Turn on system