which of the controls listed below, controls the gas pressure to the main burner, the temperature of the water, and turns off the gas when the pilot goes out.
a) ECO
b) temperature and pressure relief valve
c) aquastat
d) unitrol
d) unitrol
the components of a copper fin tube, instantaneous water heater are :
a) anti-scald device and a pump control
b) pump, pump control, flow switch temperature and pressure relief valve, and a limit control.
c) ECO temperature and pressure relief valve anonde, and a dip tube
d) temperature and pressure relief valve anode and a limit control
b) pump, pump control, flow switch temperature and pressure relief valve, and a limit control.
what does ECO Stand for
Energy control shut off device
the minimum allaowable distance to be maintained from a 50,000 btuh water heater outlet to a gas utility service regulator vent opening is
a) 1’ (300mm)
b) 2’ (600mm)
c) 3’ (900mm)
d) 6’ (1800 mm)
c) 3’ (900mm)
the minimum allowable distance to be to be maintained from a 50,000 btuh water heater flue outlet to a building opening is
a) 6” (150mm)
b) 12” (300mm
c) 2’ (6)00mm)
d) 3’ (900mm)
b) 12” (300mm)
the minimum allowable distance to be maintained from a 50,000 Btuh water heater flue outlet to a building opening is
a) 6” (150mm)
b) 12” (300mm
c) 2’ (6)00mm)
d) 3’ (900mm)
b) 12” (300mm)
what must be done to ensure equal water flow through two water heaters when they are paired together
a) install flow balancing cocks
b) ensure they are installed on the same vertical plane
c) ensure the inlet and outlet piping are equivalent lengths
d) install a mixing valve and two water regulators
c) ensure the inlet and outlet piping are equivalent lengths
What will cause a E.C.O to Open
a) a defective thermostat
b) long draws of water
c) a dip tube which is to short
d) too low of thermostat settings
a) a defective thermostat
Which of the following is used to de-lime a water heater
a) backing soda
b) tri-sodium phosphate
c) lemon juice
d) muriatic acid
d) muriatic acid
the most likely cause of a puddle of water at the side of a water heater where the drain cock and relief valve are located is that
a) the drain cock is opening intermittently
b) the relief valve is opening periodically
c) it is caused by condensation created when cold water enters the heater
d) the unitrol fitting is leaking and self re-sealing itself
b) the relief valve is opening periodically
a customer complains that the pilot goes out every once and a while. this is the second service call for this problem this month when the pilot is re-established, the closed circuit millivolt test stays at 14 millivolts. the magnet drops out at 4 millivolts what should be done next?
a) replace the gas valve because the magnet is weak
b) clean and adjust the pilot and burners
c) replace the thermocouple
d) check for another problem such as down draft or pilot position
d) check for another problem such as down draft or pilot position
what is the pressure relief valve setting for most residential type water heaters
a) 75 psig
b) 100 psig
c) 150 Psig
d) 200 Psig
c) 150 Psig
the device that water heaters use to direct the incoming water to the lower part of the tank is called
a) an anode
b) an anti-siphon device
c) a cathode
d) a dip tube
d) a dip tube
is it permitted to use water heaters for space heating only
a) yes
b) no
b) no
is leaded solder allowed on the heating portion of a combination domestic heating / hot water system
a) yes
b) no
b) no
the recommended water temperature setting from a mixing valve to the domestic water system in combination heating systems that enjoy oil-fired water heaters for heating potable water and for space heating
a) 43 C (110 F)
b) 49 C to 54 C (120 F to 130 F)
c) 60 C to 66C ( 140 F to 150 F)
d) 83 C (180F)
b) 49 C to 54 C (120 F to 130 F)
head pressure in a piping system for water heating is
a) the maximum pressure created by a particular model of pump
b) the minimum pressure created by a particular model of pump
c) the resistance of the entire piping system measured in feet of water.
d) the resistance of the entire piping system measured in PSI
c) the resistance of the entire piping system measured in feet of water.
from the following list which is the best location for a combination heating system consisting of a water heater and an air handler
a) in the insulated but unheated attached garage
b) the water heater in the basement and the air handler in a central location
c) together in a central location in the basement
d) the air handler supported on top of a rear flue water heater in a closet space
c) together in a central location in the basement
which of the following components used in a combination heating system employing a water heater may be required when a backflow prevention valve is installed in the cold water supply
a) mixing valve
b) balancing valve
c) check valve
d) expansion tank
d) expansion tank
the purpose of a mixing valve on a combination system employing a water heater to provide hot water for potable use and provide space heating is to
a) mix hot water with cold water in the heating loop
b) mix cold water with the hot water supply to the domestic plumbing system to maintain a consistent temperature of domestic hot water
c) mix cold water with the hot water supply to the heating loop to maintain a consistent temperature of water in the loop
d) return some of the water to the tank so that it does not run out of water
b) mix cold water with the hot water supply to the domestic plumbing system to maintain a consistent temperature of domestic hot water
before lighting a burner in a steam boiler, ensure that
a) there is water in the boiler
b) the temperature controller is set properly
c) the main burner test firing valve is turned on
d) the safety valves are open
a) there is water in the boiler
What safety control protects a steam boiler if the condensate pump fails to return water to the boiler
a) high pressure limit control
b) low pressure limit control
c) flame safeguard control
d) low water cut off
d) low water cut off
a low water cut off is required on a steam boiler not under continuous attendance by a certified operator, when the rated input is
a) 30,000 btuh
b) 100,000 btuh
c) 400,000 btuh
d) any value
d) any value
if it has been determined that a steam boiler burner is on and the water gauge glass indicates no water, what should be done immediately?
a) shut off the fuel supply
b) open the water supply
c) notify the building owner
d) adjust the high pressure limit control
a) shut off the fuel supply