Hydronic Radiant Heating And Heat Loss Calculations Flashcards

(33 cards)

1
Q

Where is a cushion/ expansion tank normally placed

A

Placed upstream of the circulator

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Heat transfer by movement of fluid

A

Convection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Thin layer of reflective material placed below or above the heat transfer unit to transfer heat in the direction required

A

Radiant barrier

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

1/R = ??

A

U factor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

This heating system heats a space from the ceiling down

A

Forced air system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What are the components of a finned baseboard system

A

Copper tube, aluminum fins , and an enclosure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

This heating offers radiant heating that heats the objects in the space and have little effects on the air in the room

A

Radiant infloor heating

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Is the temperature of the air in a room at different levels

A

Stratification

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Where is installing radiant floor heating not recommended

A

Below cabinets or pantry’s that store food

Underneath refrigerators and freezers increase load on those appliances

Near water closets

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Delta T is the difference between radiant floor temperature and the temperature of surrounding colder surfaces

What is the advantage of this

A

The greater the temperature difference between the two surfaces the faster the heat transfer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is not recommended with setting the room temperature with radiant floor heating ?

A

Setting back the system at night is not recommended, due to slow response time

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Most building and municipal codes require that any occupied building must have a way to exchange the air called what

A

Air exchangers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What’s important to consider these installing snow melt systems

A

Ensure proper drainage system to prevent ice build up

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

This piping meets or exceeds any of the stringent pressure and temperature tests required by code

Ideal for radiant flooring

A

Pex

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Recommended maximum lengths for infloor heating

A

3/8” ID- 76m/250’
1/2” ID- 91m/300’
3/4” ID- 152 m/ 500’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Tubing manufacturers also make headers, but these headers are pipe specific. Connecting one manufacturers tubing to another’s header does what?

A

Voids the warranty

17
Q

When connecting tubing to headers what must be followed

A

Joined per manufacturers specifications

18
Q

These are installed on manifolds to ensure equal flow rate to each circuit

A

Balancing valves

19
Q

When are balancing valves not required

A

Lass than 10% different between circuits

20
Q

Maximum floor temperature

A

140 Fahrenheit

21
Q

What temperature can the floor surface not exceed in areas where people stand for long periods

A

25 Celsius or 77 Fahrenheit

22
Q

What should the Floor surface temperature not exceed in a dwelling or commercial space

A

31 Celsius or 88 Fahrenheit

23
Q

What should Floor surface temperatures not exceed in bathrooms, indoor swimming pools and foyers

A
  1. Celsius or 91 Fahrenheit.
24
Q

What temperature should floor surfaces not exceed in radiant panel perimeter areas

A
  1. Celsius or 95 Fahrenheit.
25
What should a radiant panel be protected with?
High limit temperature control valve
26
What temperatures are considered low temperature systems
Below 140 Fahrenheit
27
What temperatures are considered high temp systems
Over 140 Fahrenheit
28
What is the calculation for U factor
1/R value = ufactor
29
For most heat lost calculations what’s recommended with rounding of the measurements
To the nearest quarter of a foot
30
The difference between the indoor design and the outdoor design temperature
Design temperature difference
31
What is infiltration based on?
BTUH per hour per cubic foot of air within a space
32
Heat is lost through the ceiling by conduction and this loss is referred to as what
Transmission loss
33
What percent must be added to the heat loss calculation in bathrooms
20%