Ice próf Flashcards
What is the maximum Takeoff and landing
altitude for the B757? (without high altitude
landing switch)
A. 8400 ft
B. 10.000 ft
C. 14.000 ft
D. No limit
A. 8400 ft
What indications can you expect when
equipment smoke is present?
A. one or both air conditioning packs switch to high flow
B. one or both recirculation fans turn off
C. the overboard exhaust valve opens
D. All correct
D. All correct
Leaving the aircraft in Burkina Faso for crew rest, 42°C OAT, electrical power on. Which procedure is required?
A. No procedure required
B. Two cabin doors open
C. One pack operating or equivalent ground cooling
D. Two packs operating is minimum required
C. One pack operating or equivalent ground cooling
The Engine anti ice operation is dependent upon engine bleed switch position
A. True
B. False
B. False
The EICAS msg „ENG HIGH STAGE“ displays when…
A. Engine bleed air temperature is excessive
B. Engine bleed air pressure is excessive
C. The engine is in high stage mode
D. The engine bleed air valve is closed.
B. Engine bleed air pressure is excessive
The EICAS msg „ENG BLEED VALVE“ displays
when…
A. Engine bleed air temperature is excessive
B. Engine bleed air pressure is excessive
C. The engine is in high stage mode
D. The engine bleed air valve is closed.
A. Engine bleed air temperature is excessive
- The EICAS msg „PACK TEMP“ displays when…
A. Pack outlet temperature is excessive
B. Pack internal temperature is excessive
C. Pack controller fault
D. All correct
D. All correct
- The EICAS msg „PACK OFF“ displays when…
A. Pack switched off
B. Pack internal temperature is excessive
C. Pack controller fault
D. A and B correct
D. A and B correct
- “The _____ recirculation fan should NOT be
turned off as this causes the overboard
exhaust valve to open.”
A. Left
B. Right
A. Left
- Equipment Cooling System. What below
describes the forward system?
A. One supply fan and Left recirc fan operate
in normal operation
B. Two supply fans and Left recirc fan
operate in normal operation
C. Only the L recirc fan operates in normal
operation
D. L and R recirc fan operate in normal
operation
A. One supply fan and Left recirc fan operate
in normal operation
- The Zone Temperature controllers are set as
follows: 22°C, 24°C, 25°C. What temperature
will the packs output?
A. 22°
B. 24°
C. 25°
D. No way to tell
A. 22°
- What is accomplished by pushing the Equip Cooling switch to ALTN?
A. Activates the alternate supply fan
B. Activates the Right recirc fan
C. Activates the Left recirc fan
D. Opens the overboard exhaust valve
A. Activates the alternate supply fan
- At what cabin altitude does the CABIN
ALTITUDE light illuminate?
a) 8500
b) 10000
c) 14000
b) 10000
- What can cause a PACK OFF light to
illuminate when the selector is in AUTO?
a) Lack of air to the pack
b) Excessive air flow
c) Trim air switch off
a) Lack of air to the pack
- What does the pack INOP light indicate?
a) Excessive pack temperature or
controller fault.
b) Loss of zone temperature controller
c) Excessive trim air temp or pack valve
closed.
a) Excessive pack temperature or
controller fault.
- What does it Indicate when the Isolation VALVE Light comes on?
a) Valve and switch positions are not in
agreement.
b) The valve is open.
c) The valve is closed.
a) Valve and switch positions are not in
agreement.
- The Trim Air Switch is off. What cabin
temperature do the packs attempt to
maintain?
a) 50°F ( 10°C)
b) 75°F ( 24°C)
c) Variable, depending upon zone
requirement
b) 75°F ( 24°C)
- What altitude setting should be set on the
LDG ALT selector during Cockpit
preparation?
a) 200 ft. below takeoff airport elevation.
b) Destination airport elevation.
c) Cabin altitude as determined from
placard.
b) Destination airport elevation.
- During automatic temperature control,
which temperature zone controls the output
of the air conditioning packs?
a) The zone requiring the coolest air.
b) The zone requiring the warmest air.
c) The zone with the warmest selection.
a) The zone requiring the coolest air.
- One forward equipment cooling supply fan operates at a time. What causes the
alternate fan to operate?
a) High temperature in the forward E/E
compartment
b) Pushing the Alternate equipment
Cooling switch.
c) Low cooling air pressure.
b) Pushing the Alternate equipment
Cooling switch.
- What limits are set by the AUTO RATE
Control?
a) Cruise altitude.
b) Differential pressure.
c) Cabin rates of climb and descent.
c) Cabin rates of climb and descent.
- What type of power is used for outflow
valve actuation during auto control?
a) DC
b) DC and AC
c) AC
c) AC
- When a pack selector is positioned to STBY N, what is the outlet temperature of the
pack?
a) Constant moderate temperature
b) Variable, dependent upon zone
requirements.
c) Full cold.
a) Constant moderate temperature
Flightcrew oxygen system; What is the normal setting?
A. 100%
B. N
Hvernig myndirðu eiga við unitið ef það væri smoke in the cockpit?
A. 100%
Myndirðu snúa takkanum til hægri, í átt að “emegerncy” möo Rotated in the direction of the arrow