Insulation And Acoustical Flashcards

(37 cards)

1
Q

FRK insulation is

A

Faced rigid board fiberglass board

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

FOil faced and faced insulation as a flame spread rating of class

A

3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How many inches from the ceiling should do the acoustical tile be installed

A

At least 4 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Kelvin scale measures what

A

Absolute temp

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The general rule is that every Doubling of the weight of a wall increases sound transmission loss by

A

5-6 db

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The outer protective insulating coat should be sprayed the temperature of

A

45degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The nominal thickness of r-19 fiberglass is

A

6-1/4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The maximum permitted load per square foot on a heavy trade scaffold

A

75 pounds per square foot

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Acoustical tile should be installed when temperature is between

A

60 and 80°

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The minimum requirement for safety wires for a light fixture in a suspended ceiling

A

2 12 gauge wires

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When installing suspended ceilings what is the minimum amount of weight a number 12 gauge wire can hold

A

90 pounds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

A pad and carpet raises the IIC but has little effect on

A

STC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

3 1/2 and FS 25 insulation as an R-value of

A

11

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Sound transmission control can be increased by three ways

A

Adding mass
Increased airspace
absorptive material

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

FSK 25 insulation is used for

A

Commercial fire resistant buildings

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

When a laser level is used to install level ceilings it is set to _ to _ below the finished ceiling height

A

1 to 2 inches

17
Q

The formula for K factor is

A

BTU/hour/square feet/degree Fahrenheit

18
Q

When there’s an expose the AC duct on the roof what type of insulation is used

A

1 inch rigid board

19
Q

What’s the best material to use when sealing around a heat source

A

Silicone caulk

20
Q

What type of insulation is used under the slab foundation for a house

21
Q

What is the maximum overhang of the scaffold plank

22
Q

The gauge wire of exposed ceiling is

23
Q

A weatherproof jacket on pipe insulation should

A

Vent vapors and prevent moisture from entering

24
Q

What is the maximum angle for Lateral bracing wire for suspended ceilings

25
For insulating a slab on grade the insulation should be
R 10
26
Polyurethane foam is not applied to machinery or storage facilities with an operating temperature of
300° f
27
The nominal thickness of r 11 fiberglass insulation is
3 1/2 inches
28
The minimum size of wall molding on an exposed grid ceiling is
3/4 inch
29
The greatest concern if the protective coating of insulation is damaged is
Lose sound absorbing properties
30
The R-value of the 1 inch thick polyurethane is
R six
31
To stop air infiltration through a heating system
Call ducks at floor penetrations
32
A duct is wrapped with Forio facing outside the wire is spaced at 18 inches on center this is correct because
It can be spaced up to 24 inches
33
FS 25 is primarily used when
It will be exposed or low flame spread rating is required
34
Z-bar ceiling systems use what gage wire
Nine gauge
35
Why use multilayered rigid board on an exposed to air conditioning duct on the roof
Vapor proofing
36
What is the minimum distance in the anchor for a suspended ceiling hanger wire must penetrate when installed in reinforced concrete
3/4 inch
37
The required height for guard rails around the trench is
42 to 45 inches