IRC 2018 Flashcards
(110 cards)
How long do you have to pick up your permit before it will be considered abandoned?
180 days
Which of the following areas are hazardous locations for glazing windows?
Swinging doors, railings, and large panes.
When can you reinstall existing slate? Clay or cement tile?
When it’s not cracked, damaged or broken
What is the minimum vertical reinforcement and spacing for a wall that is 6 ft 8 in high, with less than 3 ft of unbalanced back fill?
4 at 72
Where a fireplace opening is more than 6 ft², heart extensions shall extend how far to the front and the sides?
20 in to the front and 12 in to the sides
For proper sanitation, every dwelling shall have which of the following?
Kitchen and kitchen sink
What is a requirement for all plumbing fixtures
That they have both hot and cold water
When using metal studs, what type of fastener is required for attaching gypsum board?
No. 6 screw with bugle head style
When placing anchor bolts in a concrete floor slab, they should extend to the concrete How far?
7 in
Ends of ceiling joists shall overlap a minimum of how many inches?
3 in
If a pool is directly accessible from the dwelling, what must be in place?
An alarm which produces an audible warning when the door and or its screen are open.
In areas where expensive soils or collapsible soils are known to exist, all dwelling shall have a controlled method of water disposal from roofs that will collect and discharge roof drainage to the ground surface not less than ______ from the foundation walls or to an approved drainage system
5 ft
What is the maximum length for glass in jalousies and louvered windows?
48in
Habitable rooms shall have a ceiling height of not less than:
7 ft
What type of surface is required in bathtub and shower areas?
Non-absorbent
What is the minimum roof slope required for the installation of a metal shingle roof?
25%
Dwelling units into – family dwellings shall have what fire resistance rating?
1 hour
With bonding with prefabricated joint reinforcements, the maximum vertical spacing of the joint reinforcement shall not be more than:
16 in
On a roof, where must you install a cricket or saddle?
On any chimney or penetration more than 30 in wide perpendicular to the slope.
What are the requirements for vertical reinforcement for masonry elements?
They shall consist of at least one No. 4 for bar. Spaced no more than 48 inches. Vertical reinforcement shall be located within 16 in of the ends of masonry walls.
Pain rail height shall not be less than _______ inches and not more than___ inches.
34 and 38
How high must a porch floor or deck be above the ground to acquire a guardrail?
30 in
What is the maximum on center spacing for a mechanically fastened drip edge?
12 inches on center
What type of barrier should be applied over studs or sheathing of all exterior walls?
One layer of 15 lb felt or other approved water resistant barrier