What does Chapter 401 govern?
The materials and installation of plumbing fixtures, including faucets and fixture fittings.
What are the required characteristics of plumbing fixtures according to Section 401.2?
Constructed of dense, durable, non-absorbent materials with smooth, impervious surfaces, free from unnecessary concealed fouling surfaces.
What is the maximum water consumption for kitchen faucets in new buildings?
1.8 gpm at 80 psi.
Fill in the blank: The flow rate for lavatory faucets other than residential is _______.
0.5 gpm at 60 psi.
What does the EPA WaterSense Tank-Type Toilet Specification require?
Water closets to meet specific water consumption standards.
True or False: Remote locations for water closets are defined as being less than 30 feet upstream of the nearest drain line connections.
False.
What is the minimum clear space required in front of a water closet?
24 inches (610 mm).
What types of materials are acceptable for securing floor-mounted fixtures?
Screws or bolts of copper, copper alloy, or other equally corrosion-resistant material.
What is the maximum flow rate for kitchen faucets during temporary increases?
2.2 gpm at 60 psi.
What should be ensured where a fixture comes in contact with a wall or floor?
The joint shall be made watertight.
List the materials acceptable for flanged fixture connections.
- Copper alloy
- Hard lead
- ABS
- PVC
- Iron
Fill in the blank: Wall-hung fixtures must be supported by _______ to prevent strain on connections.
metal supporting members.
What diameter should closet rings (closet flanges) for water closets approximately be?
7 inches (178 mm).
What is the spacing requirement for urinals from a side wall?
12 inches (305 mm).
What should the connections between drainage pipes and fixtures be made with?
Approved materials and designed to accommodate an adequately sized gasket.
True or False: The clear space in front of water closets and bidets in dwellings must be at least 21 inches.
True.
What is the maximum flush volume for urinals according to the specifications?
0.25 gallons/cycle.
What type of supports must floor-affixed supports for off-the-floor plumbing fixtures comply with?
ASME A12.6. IM.
What materials are acceptable for closet rings (closet flanges)?
- Copper alloy
- Copper
- Hard lead
- Cast-iron
- Galvanized malleable iron
- ABS
- PVC
What is the required surface for public shower floors?
Nonskid surface
Floors must be designed to prevent slipping to ensure safety.
What is the minimum slope required for gutters in public shower rooms?
2 percent toward drains
This slope is necessary for effective drainage.
What is the maximum distance between drains in public shower rooms?
16 feet (4877 mm) apart
Drains must be spaced for adequate drainage.
Where should control valves and showerheads be located in shower compartments?
On the sidewall
They should not discharge directly at the entrance.