Masonry Chimney Problems Flashcards
(8 cards)
List 22 Masonry Chimney problems
- Excessive offset from vertical
- Chimney too short
- Cleanout door too close to combustibles, loose or missing
- No liner
- Cracked or broken liner
- Incomplete liner
- Inadequate clearance from combustibles
- Fire stopping missing or incomplete
- Cap missing
- Cap cracked
- Improper slope on cap
- No drip edge on cap
- Creosote buildup in flues
- Vent connector extending into chimney
- Vent connector loose at chimney
- Flue or vent connector obstructed
- Draft inducer fan inoperative
- Rusted chimney extender
- Chimney extender stuck
- Too many appliances on flue
- Abandoned opening for flue connections
- Undersized screen on spark arrester
What is the maximum that a chimney can be offset from vertical?
30° maximum
How far should a masonry chimney extend above the roof?
Three feet minimum and two feet above anything within 10 feet horizontally.
What is the minimum total height for a chimney serving a wood stove?
Minimum 15 feet
When did masonry chimneys start to get built with clay liners?
Approximately the 1950s
You can tell whether a chimney is lined by looking for a liner extending above the top.
False
Generally speaking, how far should wood framing members be kept away from masonry chimneys?
Minimum two inches
Two wood burning fireplaces can share a single flue, as long as they are on the same floor level.
False