Mock Exam Flashcards
An inspector enters a vacant home to inspect it and notices a strong smell of gas.what should he do?
Vacate The home and call all appropriate people
What was added to furnaces in 1980 to increase efficiency:
Two heat exchangers
What material is not a proper flashing material : A.copper B.galvanized C.aluminum D.tar paper
D.tar paper
A three prong receptacle requires
Grounding conductor
The neutral wire:
Returns 110v to ground
Ice forming on the A/C evaporator coil is caused by:
Not enough air
The exhaust vent of a gas dryer:
Must be vented to the outside
Deck built 14” off ground around a home
Requires no railing
In an electrical sub panel,the neutral wire must be
Both separated from ground and isolated
Trusses :
Have two bearing points
You see a return air register in the side of a furnace:
Can cause flue gases to be drawn into supply air.
Mid-efficiency furnace
No draft diverter required
What is the proper exposure for a 24” Shake
10”
Safety glazing is not required in:
Greater than 10 sqft over 18” above floor
Stucco hairline cracks appear every 16”. The cause can be attributed to:
Nailing drywall on inside
On a tile roof what is the proper way to flash around the chimney
Counter and pan flashing
You are inspecting a home built in 1950 and see a silver wire to a branch circuit. This would be:
Tin coated copper
Moisture accumulates in poorly vented attic because
Warm air rises and condenses in the attic
What is the proper exposure for an 18” wood shake
7 1/2”
You view a type “B” vent in an attic. Insulation is falling in the open chase.what do you report
A. What you see
B.recommend a fire stop be installed
C.recommend they remove insulation from chase
D. All The above
D. All the above
What determines the size of flue
Opening of fire place
Metal chimney cap function does not include: A. Keeping animals out B. Keeping out rain C. Keeping debris out D. Reducing draw of exhaust gases
D. Reducing draw of exhaust gasses
Cross bridging on floor joists:
Keeps joists from twisting
Potential problems with roof sheathing is: A. 3/8" plywood used B. Ends touching each other C. Plywood placed parallel to rafters D. All the above
D. All the above