Modern Refrigeration and AC Flashcards
(52 cards)
When liquid refrigerant enters the evaporator, the refrigerant is suddenly at a (High Temp and High Press, Low Temp and High Press, Low Temp and High Press or High Temp and Low Press)?
At a low pressure and a high temp
What is used to control the capacity of a commercial compressor?
Unloaders
All of the following effect the capacity of a TXV (thermostatic expansion valve) except an ____________ ________________.
An external equalizer
What system uses a silicone carbide igniter?
Hot surface
What is the process of expanding or enlarging a copper tube to receive another copper tube?
Swaging
All are true of a muffler except…
Can be installed only on intake of compressor
What device prevents slugging in a heat pump system?
Accumulator
Type of circuit where components are arranged in ladder like arrangement?
Parallel circuit
A starter relay drops which of the following out of the circuit?
Start windings
Thermal device that opens its contacts when motor heater coil uses too much voltage is called a _____________ _________.
Thermal relay
How do cooling towers cool?
By evaporation
What color is a dot in a moisture site gage system when indicating a dry system?
Green
A suction line riser should have a trap installed at the lowest point to….
provide reservoir for oil that drips down riser
A yellow tip flame indicates a lack of primary ______ when burning fuel gases in a furnace
primary air
What determines defrost termination on a heat pump system using time initiated, temperature terminated defrost cycle?
Outdoor coil
What does white smoke from an oil burner indicate?
Lein oil and air mixture
Highest temperature at which substance may be liquefied regardless of pressure?
Critical temperature
What rating measures furnace efficiency?
AFUE
What is the purpose of a condenser?
Cools refrigerant to desired temperature
From the expansion valve, the external equalizer runs to…
The outlet of the evaporator
Raising superheat will ____________ an evaporator?
Starve
A device without moving parts that converts ac voltage to a different voltage is called a _________________.
Transformer
Control for refrigeration unit is set to cut in at 45 degrees and out at 35 degrees. If the setting is changed to 45 degrees cut in and 36 degrees cut out, the compressor will have to… (Run less and cycle more or OR run more and cycle less?)
Run less and cycle more
A tech finds discharge pressure on a fully charged system is low due to low ambient temperature. How do you resolve this?
Install low ambient fan control