NFPA 10 Chapter 1-3 Flashcards
(36 cards)
What is the Conversion Factor for Millimeter?
1 in. = 25.4 mm
Low pressure cylinders contain how much service pressure?
500 psi
Bromo-chloro-Di-fluoromethane
Halon 1211
Bromo-TRI-fluoromethane
Halon 1311
A powder composed of very small particles, usually sodium bicarbonate, potassium bicarbonate, or ammonium phosphate with added particulate material supplemented by special treatment to provide resistance to packing, resistance to moisture absorption (caking), and the proper flow capabilities.
Dry Chemical
System constructed in a manner that DOES NOT introduce foreign material into the agent being recovered.
Dry Chemical Closed Recovery System
Indicates a mandatory requirement
Shall
Acceptable to the authority having jurisdiction
Approved
The PROVISIONS of this standard apply to the selection, installation, inspection, maintenance, recharging, and testing of portable fire extinguishers.
Scope
This STANDARD is prepared for use by and guidance of persons charged with selecting, purchasing, installing, approving, listing, designing and maintaining portable fire extinguishers .
Purpose
NFPA 96
Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, 2011 edition
NFPA 303
Fire Protection Standard for Marinas and Boatyards
NFPA 500
Building Construction and Safety Code
Solid materials in powder or granular form designed to extinguish Class D combustible metal fires by crusting smothering
Dry Powder
those with a depth greater than 1/4in (6.3mm)
Flammable Liquids of Appreciable Depth
pressure shown on the nameplate at which a shell was tested at time of manufacture
Factory Test Pressure
Vehicles will be inspected _________
Annually or as deemed necessary
Fire Equipment Dealer who does not want to engage in servicing halon equipment must file what affidavit?
Fire Equipment Dealer Halon Exemption Affidavit
Each licensed business location shall be required to possess, at a minimum, the required equipment listed below, the equipment shall be demonstrated at the time of any inspection, to be functional to perform services as indicated by the license.
Hydrostatic test for high pressure testing
Equipment for test dating United States DOT
Die stamps for Class A & D facilities
Clock with sweep second hand or digital clock
CO2 receiver bulk
Conductivity tester & Tags
Scales
Any change of corporate officers must be reported within
14 days
License and permit applications to reflect change of residence, principal business or name shall be done within
30 days
True or False.
No licensee shall conduct his or his licensed business under a name other than the name which appears on his or her license.
True
Continuing Education hours (CEUs)
1 hour business practices class, 1 hour workers comp., 14 hours technical
(16 hours total)
True or False.
a permittee changing his or her place of employment shall obtain a new permit under the license of the license-holder at the new place of employment.
True