Overview Flashcards
(33 cards)
Axedo 450-2 and Axedo 600 chambers are an example of what type of chamber in accordance with Sewers for Adoption 7?
Type 3 (Flexible Material)
If a scheme is to be adopted under a Section 38 approval, who is likely to adopt and maintain the drainage?
Local Council/Highways Authority
Which section of Sewers for Adoption 7 governs the use of Thermoplastic Structured Wall Pipe systems (such as ULTRA3)?
E 2.22
If a drainage scheme is to be adopted under an S104 agreement all parts of the system serving 2 or more residential properties will be adopted by the local water authority if built to acceptable standards. True or False?
True
If a drainage scheme is to be adopted under an S106 agreement which of the following best describes the process:
- The local water authority will adopt the entire drainage network on commercial sites only.
- Only the drainage serving the road areas will be adopted. This will be adopted by the local council/highways authority.
- All of the drainage will be adopted as long as it meets the requirements of SfA7.
- There is an agreement to discharge into an existing adopted public sewer. The bulk of the system will remain private but the final connection will need to be to Sewers for Adoption standard.
- There is an agreement to discharge into an existing adopted public sewer. The bulk of the system will remain private but the final connection will need to be to Sewers for Adoption standard.
Section 104 and Section 106 are part of what legislation?
Water Industry Act 1991
According to Building Regulations Part H 2015 what is the minimum recommended fall for a foul water pipe with a minimum of 1 WC connected?
1:80
According to Building Regulations Part H 2015 what is the maximum distance that two Axedo 600 chambers can be from one another on a drainage run?
45 Metres
Which section of Sewers for Scotland 3 governs the use of Thermoplastic Structured Wall Pipe systems (such as ULTRA3)?
4.2.22
What are the 2 main differences between the installation details shown in SfA7 and SfS3 for PCC manholes constructed using standard width chamber sections?
- SfS3 does not require the entire chamber to be encased in cast in situ concrete.
- SfA7 requires a minimum of 2 courses of engineering bricks whereas SfS3 will allow for 1 course.
According to Building Regulations Part H 2015 what is the minimum distance from a building that a drainage field can be installed?
15 Metres
According to Building Regulations Part H 2015 what is the minimum distance from a building that a surface water soakaway can be installed?
5 Metres
When designing surface water soakaways we would typically follow the guidance of what document?
BRE Digest 365
What guidance document would we use to size a sewage treatment system correctly?
Flows and Loads 4
According to section E2.22 of SfA7, alongside BS EN 13476 what other approval should Thermoplastic Structured Wall Pipe have to be suitable for adoptable applications?
WIS 4-35-01
According to Table 13 of Building Regulations Part H1 2015, what is the maximum allowable spacing between two Axedo 450-2 chambers?
45 Metres
According to Table 13 of Building Regulations Part H1 2015, what is the maximum allowable spacing between an Axedo 600 chamber and a man entry PPC manhole?
90 Metres
According to Flows and Loads 4, what flow of waste water is produced per person, per day in a standard residential domestic dwelling?
150 Litres
According to BRE Digest 365 any soakaway should drain from full to half full within what time period?
24 Hours
A surface water soakaway could be constructed if which of the following statements is true?
- The half drain time is greater than 24 hours
- Groundwater reaches the base level of the soakaway during annual variations in the water table.
- The system will be within 5m of an existing building.
- The system will be sited in sandy soil.
- The system will be sited in sandy soil.
If a drainage system is being constructed in accordance with MCHW Series 500 and they have requested a Type 7 chamber what will the chamber diameter be?
1050mm
What does BBA stand for?
British Board of Agrement
Which figure in Sewers for Adoption 7 shows the allowable construction type for Axedo 450-2 or Axedo 600 chambers?
B.16
According to Flows and Loads 4, if a sewage treament plant is to serve a single house with 3 bedrooms what is the minimum poulation capacity (P) that the system should be designed for?
5 P