PD 1096 - Chapter 6 Flashcards

(56 cards)

1
Q

Minimum thickness (mm) for 1hr fire resistance: Solid RC Slab, average cover to reinforcement

A

15

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Minimum thickness (mm) for 2hr fire resistance: Solid RC Slab, average cover to reinforcement

A

20

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Minimum thickness (mm) for 3hr fire resistance: Solid RC Slab, average cover to reinforcement

A

25

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Minimum thickness (mm) for 4hr fire resistance: Solid RC Slab, average cover to reinforcement

A

25

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Minimum thickness (mm) for 1hr fire resistance: Solid RC Slab, overall depth

A

100

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Minimum thickness (mm) for 2hr fire resistance: Solid RC Slab, overall depth

A

125

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Minimum thickness (mm) for 3hr fire resistance: Solid RC Slab, overall depth

A

150

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Minimum thickness (mm) for 4hr fire resistance: Solid RC Slab, overall depth

A

150

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Minimum thickness (mm) for 1hr fire resistance: Pre-stressed Concrete Slab, average cover to tendons

A

25

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Minimum thickness (mm) for 2hr fire resistance: Pre-stressed Concrete Slab, average cover to tendons

A

40

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Minimum thickness (mm) for 3hr fire resistance: Pre-stressed Concrete Slab, average cover to tendons

A

50

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Minimum thickness (mm) for 4hr fire resistance: Pre-stressed Concrete Slab, average cover to tendons

A

65

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Minimum thickness (mm) for 1hr fire resistance: Pre-stressed Concrete Slab, overall depth

A

100

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Minimum thickness (mm) for 2hr fire resistance: Pre-stressed Concrete Slab, overall depth

A

125

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Minimum thickness (mm) for 3hr fire resistance: Pre-stressed Concrete Slab, overall depth

A

150

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Minimum thickness (mm) for 4hr fire resistance: Pre-stressed Concrete Slab, overall depth

A

150

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Minimum thickness (mm) for 1hr fire resistance: Partition, solid concrete

A

125

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Minimum thickness (mm) for 2hr fire resistance: Partition, solid concrete

A

150

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Minimum thickness (mm) for 3hr fire resistance: Partition, solid concrete

A

175

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Minimum thickness (mm) for 4hr fire resistance: Partition, solid concrete

A

175

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Minimum thickness (mm) for 1hr fire resistance: Partition, solid masonry

A

125

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Minimum thickness (mm) for 2hr fire resistance: Partition, solid masonry

A

150

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Minimum thickness (mm) for 3hr fire resistance: Partition, solid masonry

24
Q

Minimum thickness (mm) for 4hr fire resistance: Partition, solid masonry

25
Minimum thickness (mm) for 1hr fire resistance: Partition, hollow unit masonry
150
26
Minimum thickness (mm) for 2hr fire resistance: Partition, hollow unit masonry
200
27
Minimum thickness (mm) for 3hr fire resistance: Partition, hollow unit masonry
250
28
Minimum thickness (mm) for 4hr fire resistance: Partition, hollow unit masonry
300
29
Minimum thickness (mm) for 1hr fire resistance: Protection for metal structural members, concrete
25
30
Minimum thickness (mm) for 2hr fire resistance: Protection for metal structural members, concrete
38
31
Minimum thickness (mm) for 3hr fire resistance: Protection for metal structural members, concrete
50
32
Minimum thickness (mm) for 4hr fire resistance: Protection for metal structural members, concrete
75
33
Minimum thickness (mm) for 1hr fire resistance: Protection for metal structural members, masonry
38
34
Minimum thickness (mm) for 2hr fire resistance: Protection for metal structural members, masonry
55
35
Minimum thickness (mm) for 3hr fire resistance: Protection for metal structural members, masonry
75
36
Minimum thickness (mm) for 4hr fire resistance: Protection for metal structural members, masonry
100
37
Minimum thickness (mm) for 1hr fire resistance: Protection for metal structural members, metal lath with vermiculite or perlite gypsum plaster
12
38
Minimum thickness (mm) for 2hr fire resistance: Protection for metal structural members, metal lath with vermiculite or perlite gypsum plaster
20
39
Minimum thickness (mm) for 3hr fire resistance: Protection for metal structural members, metal lath with vermiculite or perlite gypsum plaster
38
40
Minimum thickness (mm) for 4hr fire resistance: Protection for metal structural members, metal lath with vermiculite or perlite gypsum plaster
50
41
Minimum thickness (mm) for 1hr fire resistance: Exterior wall, solid concrete
75
42
Minimum thickness (mm) for 2hr fire resistance: Exterior wall, solid concrete
125
43
Minimum thickness (mm) for 3hr fire resistance: Exterior wall, solid concrete
150
44
Minimum thickness (mm) for 4hr fire resistance: Exterior wall, solid concrete
180
45
Minimum thickness (mm) for 1hr fire resistance: Exterior wall, solid masonry
100
46
Minimum thickness (mm) for 2hr fire resistance: Exterior wall, solid masonry
150
47
Minimum thickness (mm) for 3hr fire resistance: Exterior wall, solid masonry
175
48
Minimum thickness (mm) for 4hr fire resistance: Exterior wall, solid masonry
200
49
Minimum thickness (mm) for 1hr fire resistance: Exterior wall, hollow masonry
150
50
Minimum thickness (mm) for 2hr fire resistance: Exterior wall, hollow masonry
200
51
Minimum thickness (mm) for 3hr fire resistance: Exterior wall, hollow masonry
250
52
Minimum thickness (mm) for 4hr fire resistance: Exterior wall, hollow masonry
300
53
Minimum thickness (mm) for 1hr fire resistance: Column, reinforced concrete (all faces exposed)
200
54
Minimum thickness (mm) for 2hr fire resistance: Column, reinforced concrete (all faces exposed)
300
55
Minimum thickness (mm) for 3hr fire resistance: Column, reinforced concrete (all faces exposed)
400
56
Minimum thickness (mm) for 4hr fire resistance: Column, reinforced concrete (all faces exposed)
450