PLUMBING Flashcards

(74 cards)

1
Q

A 60 US gallon water heater weighs 52.5lbs when its empty. How much does it weigh when its full?

A

552.3lbs

60usgal x 8.33lbs/usgal = 499.8lbs

499.8lbs + 52.5lbs= 552.3lbs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is installed either as part of a grease interceptor or immediatly at the inlet connection point to make it more efficient?

A

Flow control device

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What would be the result of a partially plugged bypass orifice in a flushometer?

A

Long flush cycle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The inner dimmension of a grease interceptor measures 9’ long, 4’6” wide and 5’ deep with a required 20% free board. What is the liquid capacity in the interceptor in Imp gallons?

A

9’ x 4.5’ x 5’ = 202.5cubic feet

202.5cubicft x 0.8(20%) =162cubicft

162cubicft x 62.4lb/cubicft =10108.8lb

10108.8lb / 10impgal/lb = 1010.88impgal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When cutting borosilicate glass tube what lubricant should be used?

A

Water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What length of cast iron soil pipe should be removed when installing an MJ wye?

A

1/4” to 1/2” longer than the wye

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What method, in addition to concrete thrust blocks, can be used to further restrain spigot PVC water service joints from seperating?

A

Serrated harnesses with lugs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the required flow rate for a system that has a total heat loss of 175000 BTU and a DELTA T of 15°F?

A

(175000 BTU/hr) / (8.33lb/usgal x 15°F x 1 BTU/lb/°F)

After units cancel
175000 (hr) / (8.33 (usgal) x 15)
175000 (hr) / 124.95 (usgal)

= 1400.56 USgal/hr

(1400.56USgal/hr) / (60min/hr)

= 23.3 GPM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What effect would a larger DELTA T have on an appliance?

A

BTU output would increase

  • increase water temp
  • decrease air temp
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

A hydronic heating system requires an in-line flow switch. Where would this type of switch be located?

A

Supply main

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is required when installing long, straight horizontal or vertical runs of copper domestic hot water piping?

A

Expansion joint

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the ideal DELTA P for compressed air systems?

A

15 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Intercoolers are installed with which style of compressor?

A

On two stage compressors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Air intakes for compressor systems should be located where?

A

In the coolest place possible

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The inspector can ask for a minimum of ___ fittings in a medical gas to be removed and inspected to see if there is oxidation present?

A

3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Where is the in-line high pressure sensor for a medical gas system located?

A

Downstream of the pressure regulator

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Freeze packs are designed to work on ______ water

A

Standing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

What is the minimun size of copper tube permitted for medical gas distribution systems?

A

1/2”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

If performing hot work on a frozen line what must be done?

A

Re apply freeze pack to the site every 15 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

All medical gases must be tested for the purity of the gas. What concentration must those gases be at?

A

100% oxygen, nitrogen and nitrous and 21% for medical air

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

If you have a medical gas system with with an anticipated operating pressure of 125 psi what pressure test would it need to maintain to pass inspection?

A
  1. 5 psi for 24 hours

1. 5x operating

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Which fixtures and appliances must be installed with a shut-off valve in a public building?

A

All fixtures and appliances

Private (residential) only requires water closet, building iso and hot water tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

What water treatment equipment is required if coliforms are detected in a water supply?

A

Chlorinator

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

If there is a pressure of 50 psi at street level, how high will the pressure lift water contained in a 2” veritcal water pipe?

A

50psi x 2.31psi/foot = 115.5’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
A jet pump was seen operating properly at instllation. The installer properly set the cut in and cut out to 30-50psi. Months later the owner is seeing pressures as high as 70 psi before the pump shuts down. What is most likely the reason?
Obstructed or slightly kinked pressure switch tubing
26
What is the minimum size water service?
3/4”
27
Polybutylene piping should not come in contact with what?
Chlorine
28
What is your grade % if you have 216” of drop and 500’ of run?
500’ x 12” = 6000” 6000” / 216” = 0.036 0.036 x 100 = 3.6%
29
How many GPG does soft water have?
Less than 1 gpg (hardness)
30
Where a 4” building trap is installed in a system what provisions must be met?
- it must have a cleanout upstream and downstream of the building trap - must have a 4” fresh air inlet not more than 1.2m upstream of the building trap
31
What is a class K fire extinguisher used for?
Grease
32
What device is installed on the downstream side of a high pressure steam safety valve that vents to the roof?
Drip pan elbow
33
What is the purpose of an insulated service valve insatlled on gas pipe exiting the ground and entering the building?
It breaks the contact between the ground and the building piping
34
How should you properly prepare a CPVC end?
Deburr and bevel
35
Regarding DWV piping, what is the maximum plus or minus pressure allowed in a system?
1” WC
36
A PVC DWV system is running horizontally for 136m, how many clevis hangers will need to be ordered?
PVC/ABS hanger spacing = 1.2m 136m / 1.2m = 113.333333 Round up add 1 =115
37
What can be installed to correct periodic discharge from a reduced pressure principle backflow preventer when the water distribution pressure is expected to fluctuate?
Install a swing check upstream of the RP
38
What would the size of the required yoke vent be in a high rise if the vent stack is 2” and the waste stack is 3”?
11/2” 1 size smaller than smallest connected pipe
39
The base of a soil stack is 6” in diameter and the stack vent on top of it is 3” in size. The stack is required to have a nominally horizontal offset greater than 1.5m. The offset relief vent required on either side of the offset will be required to be what size?
2” 1 size smaller than the stack vent
40
What is the minimum sized vent that must be provided for any future installations in a building?
11/2”
41
A flat roof that measures 25m x 50m with a perpendicular wall that is 7m x 50m will require what size leader if local rainfall intensity is 20mm for 15 minutes?
25m x 50m = 1250m 7m x 50m = 350m - Take 50% of perpendicular wall area 350m x 0.5 = 175m 1250m + 175m = 1425m 1425 x 20(rainfall intensity) = 28500 Size off of 2.4.10.11 (6” leeder)
42
What fitting would be used to attatch a field cut glass tube to a non-field cut glass tube?
Bead to Plain
43
What decice is required on a water supply connecting to the bottom of a commercial hot water heater?
Vaccume relief valve installed at least 6” above the tank
44
What provision must be made for a gas room heater insatalled in a hallway in a seniors home?
Must be vented type | Applicable in any public place
45
How should a threaded joint be made between threaded galvanized steel piping and copper tubing?
Brass MIP
46
What determines the minimum size of a suction pipe on a well pump?
Size of the inlet of the pump
47
What is the sacrificial anode in a hot water tank manufactured from?
Magnesium
48
Steel piping comes in what usual lengths?
6m 21 feet in the real world
49
What color codes are type k, l and m copper?
K (kermit) = green L (lake) = blue M (murder) = red
50
What type of thread is on acetylene fittings?
Left
51
A 3/4” extracted tee may be formed from?
1” type K Tee is 1 size smaller than pipe size and always use type K
52
What force would be exerted on a 9” blind flange at the base of a 30’ column filled with water?
Convert feet to psi 30’ x 0.433psi/foot = 12.99 psi Find surface area of flange A= 3.14(4.5)Squared A= 63.585 63.585 x 12.99 = 825.98psi
53
How do you convert height into pressure? How do you convert pressure into height?
#feet x 0.433 #psi x 2.31
54
What should the relief valve on a compressed air receiver tank be set to discharge at if the cut out pressure of the compressor is set to 45psi?
55 psi 10psi above cut out
55
What size is the cleanout on a 6” sanitary building drainas it exits a building?
4”
56
What backflow preventer is not testable?
DuC Dual check valve
57
How do you determine maximum trap arm length?
Fall of 1 pipe diamter
58
What is the maximum practical lift of a shallow well pump?
25’
59
What provision must be made for an autopsy table that receives potentially dangerous bio-hazard waste?
Must be installed with a cleanout above flood level rim
60
How should piping in a pneumatic system be installed?
Graded towards the oulets with branches rising up off the mains
61
A combined building sewer has a sanitary hydraulic load of 549 fixture units and 8 rainwater leaders with 2750 litres each. What size is the sewer graded at 1%?
2750L x 8 = 22000L 549 FU X 9.1L/FU = 4995.9L 22000L + 4995.9L = 26995.9 Size according to 2.4.10.9 (10”)
62
How many pounds are in a US gallon?
8.33 lb/gal Example… 60USgal x 8.33 lb/USgal = 499.8lb
63
How much does 1 cubic foot of water weigh?
62.4 lb/cubicft
64
How many litres are in an imperial gallon?
4.54 l/impgal
65
How do you calculate linear expansion?
Table A-2.3.3.9. Length change = original length x coefficient of expansion x temp change
66
The waste for the closed coupled tank type W.C. is roughed in at?
305 mm (12") from finished wall
67
A blowout W.C. cannot be?
Horizontally wet vented
68
A floor drain can be protected from back flow by a?
Gate valve | Screw cap
69
The minimum distance permitted between two shower heads is?
750mm
70
A relief vent is most closely related to a?
Vent stack
71
Not more than how many showers can be served by one drain?
6
72
A yoke vent is required when the soil or waste stack extends through a number of storeys. An additional circuit vent is also required when?
More than 8 fixtures are installed between vents
73
The minimum air break for an indirect waste pipe that is 1 ¼" is?
1 1/4”
74
Which does not require a vent?
a) Lavatory trap b) Trap forming part of an indirect drainage system c) Trap on a subsoil drainage system d) Sewage sumpe Either b) or c) Answer: c)