Pneumatics Flashcards
(41 cards)
Trim air switch when turned on allows automatic and manual selection of pack controllers A or B enabled. True or False
TRUE (FCOM 2.10.5)
Pilot auxiliary heat is provided by____ elements
electric (FCOM 2.20.12)
Equipment cooling system provides cooling air for____
flight deck equipment and to the electrical and electronics compartment (FCOM 2.20.12)
Cabin Altitude Controller in Cruise Mode has a maximum of___
8,000’ (FCOM 2.30.2)
Landing elevation limits are___below mean sea level to___above mean sea level
-1,000’ to + 14,000’ (FCOM 2.30.2)
Pack control selector switch in the normal position does
alternate automatically between a or b (FCOM 2.10.9)
The flight deck fan switch on and all packs off there is no airflow to cockpit. True or False
FALSE - Supplies recirculated air (FCOM 2.20.4)
Trim air switch turned on all flight deck zone trim air valves operate automatically except
NONE - Flight deck main deck trim valves opearate automatically
Aft cargo heat switch ON provides bleed air heat to
aft and bulk cargo compartments (FCOM 2.10.8)
Engine Bleed Air Fault Light is caused by
Bleed air overheat or overpressure…or PRV open when commanded closed (FCOM 2.10.16)
Three airconditioning packs draw air from
engines\APU\external that supply the bleed air duct (FCOM 2.40.1)
The pack valve is____controlled and___operated.
electrically, phematically (FCOM 2.20.2)
The temperature zone requiring the warmest temperature controls the pack outlet temperature. True or False
FALSE
Closing the right isolation valve will prevent bleed air from reaching hydraulic demand pump 4. True or False
False. (FCOM 2.40.5)
With the pax temp selector in auto and the system operating normally, which temp. zone determines the outlet temp of the packs?
the zone requiring the coolest temp (FCOM 2.20.7)
What does selecting the equipment cooling selector STDBY position do?
Manually reconfigures the cooling equip in flight for FLIGHT situation(FCOM 2.10.6)
In flight, what does placing the captain’s foot heater switch to LO or HI do?
under floor electric heater operates at high\low rate (FCOM 2.10.12)
Shoulder and foot heaters operate in flight only. True or False
TRUE (FCOM 2.10.11)
When is the EICAS warning message CABIN ALTITUDE displayed?
cabin altitude > 10,000’ (FCOM 2.50.1)
Placing the landing altitude in manual (Amber landing altitude displayed, all data is displayed landing elevation def. pressure etc)
Done when this data is missing from the FMS (FCOM 2.10.14)
What does selecting the equipment cooling selector OVRD position do?
Provides cooling, uses reverse airflow for diff pressure. (FCOM 2.10.6)
With a pack control selector in the NORM position, which of the following is correct? All answers correct
pack a or b selected automatically on alternate flights as primary controller while the other one is selected if the primary has failed (FCOM 2.10.9)
The cabin pressurization system is normally fully automatic, but the outflow valves may be positioned manually. True or False
TRUE (FCOM 2.10.15)
At what cabin altitude will the outflow valves close in the automatic mode?
11,000’ (FCOM 2.30.2)