Power Generation Flashcards

(27 cards)

1
Q

Two types of interfaces?

A

Power ( Voltage) and Signal ( Comms)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the purpose of PWRSS?

A

Fire Control Equipment receiving primary power.

Buffers, converts, regulates, distributes, monitors and controls supplied power

SWS[Loads] launcher, DRS, MTRE, VAMP, Swsmin, missile

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Purpose of tie breakers?

A

Connects 1-2:source together. If one removed there is still a supply to FC systems

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What Equipment makes up the PCME

A

PDE PBE PCE PMCE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What Equipment is in the PCME?

A

6xPMA 3xVSA 2xAMA 1xDC voltmeter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How many buffers to launch missile

A

Any 2 of 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Alarm indication on 5v?

A

Indicating push button, to observe supply and reset.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Indication of PWRSS on each door

A

Visual indicator of abnormal status, provided by
PDE PBE PCE PCME

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

270v DC ground fault

A

Resistance between leg of distribution and ground Less than 75K ohms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

28v DC ground fault

A

Distribution and ground Less than 7K - 62K ohms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Online monitoring, threshold impedance

A

Impedance path of less than 9K ohms to ground

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Purpose of the PPS?

A

Provide 115v 1ph 5.1Khz power to the Command sequencer and permit setting of RBA fuses

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Two methods of detecting ground faults

A

Online fault monitoring- continuous
Ground fault test SMP- periodic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

PCM

A

Software program that executes in the DCSS
Displays at Fire Control console

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Name two missile test modes?

A

Fuse test and Tactical mode

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Purpose of a DC Convertor Function

A

Top provide a stabilise 270vdc to SWS (Fire Control )

17
Q

What range can DC- DC Convertor operate?

18
Q

What is the Purpose of 35KW MG’s

A

Supply 120v 3p 400hz to ships services
Alternate is 2x 10Kw for Nav equipment

19
Q

What is the voltage range and over volt limit

A

10% range with 351 over volt limit

20
Q

What is the output of the 400hz mg

A

120V 3ph 400Hz

21
Q

Where is the 1SF switchboard located?

A

MCC passageway outside entrance to MCC

22
Q

Checks on switchboard and MG

A

Check voltmeter
Check frequency
Check MG output ammeter ( not overloaded)
Check DC ammeter ( not overloaded)
Check MG for noise, vibration and sparking
Check MG temperatures

23
Q

What is done to brushes if off for an extended period?

A

Lift brushes and place insulating NOMEX between brushes and commutator

24
Q

What is to be turned of after shutdown of MG?

A

CW water supply to stop condensation

25
What speed does the over speed trip operate?
Contacts open automatically to secure MG at 1972 +- 20rpm
26
What is the purpose of the motor controller?
DC magnetic controller, connects to the drive end of MG to ships 270vdc distribution system
27
Periodic checks on SB and MG
Check voltmeter Adjust rehostst Check frequency meter Check for noise, vibration and sparking Check for air temperature