Powerplant Operation Flashcards

(33 cards)

1
Q

Min idle mixture rise leaned to peak (runup/shutdown)

A

50

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Min rpm during engine runup idle check

A

975

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Min rpm for in-flight (area) idle beyond gliding range of a runway

A

1400

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Min permissible static rpm (full throttle runup)

A

2000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Tachometer normal operating range (rpm)

A

700-2800

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Max permissible continuous rpm

A

2800

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Min rpm drop during magneto check

A

25

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Max rpm drop during magneto check

A

150

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Max rpm drop difference between magnetos

A

50

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Max permissible continuous bhp

A

125

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Min oil pressure

A

10 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Oil pressure normal range

A

30-60 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Max time for oil pressure to reach 10 psi after start

A

30 second

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Max oil pressure for full power operation if
OAT < 0°C

A

70 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Max oil pressure

A

100 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Min oil temperature

17
Q

Max rpm after start until oil temp indication registers

18
Q

Oil temperature normal operating range

19
Q

Min oil temp to begin an area SFL at Area Idle

20
Q

Min oil temp for full power operation if oil pressure 100 °F

21
Q

Max oil temperature

22
Q

Min oil quantity

23
Q

Max oil quantity

24
Q

Fuel pressure lower limit red line

25
Fuel pressure upper limit red line
16.5 psi
26
Max continuous starter operation
10 second
27
Max cumulative starter op before cooling 3-5 min
30 second
28
Max time for CHT below 300 °F in descend
5 minutes
29
Min CHT takeoff & descend
240 °F
30
CHT normal operating range
300-420
31
CHT Caution range
420-460 °F
32
Max CHT
460°F
33
Engine model & type?
Continental motors - IO-240-B