RadEye Flashcards

(25 cards)

1
Q

What does the acronym SPRD stand for?

A

Spectroscopic Personal Radiation Detector

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What type of scintillator does the RadEye SPRD-GN use?

A

CLYC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the main function of Pulse Shape Discrimination (PSD) in the RadEye SPRD-GN?

A

To distinguish between gamma and neutron radiation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Which colored LED indicates a gamma alarm

A

Orange

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the recommended maximum gamma dose rate for accurate readings on this device?

A

250 µSv/h

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Which function allows differentiation between man-made and natural radiation?

A

Natural Background Rejection (NBR)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How is a neutron alarm visually indicated?

A

Blue LED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What must be done before inserting new batteries?

A

Switch the unit off and wait ~5 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How long does the learning phase last after startup?

A

16 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What information is displayed during startup?

A

Time/date, firmware, calibration date

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is shown by the bar graph in the basic display?

A

Intensity of radiation relative to thresholds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What happens when the “ON” button is held for more than one second?

A

Unit powers on

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the purpose of the Lu-Adjust?

A

Calibrate energy response using a Lutetium source

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What does the “Finder mode” do?

A

Produces varying tones based on radiation intensity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

How can the scaler mode be accessed?

A

Through the “Operation mode” submenu

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

In nuclide ID mode, what does a confidence level below 6 suggest?

A

Repeat measurement with longer acquisition

17
Q

What symbol is shown when auto-adjust is active?

A

Pulsing heart

18
Q

What is required to keep RTC running during battery replacement?

A

Replace batteries quickly without delay

19
Q

What is the function of the “Cross-mode”?

A

Combines dose rate display with count rate bar

20
Q

Which of the following can trigger an automatic nuclide ID?

A

Reaching preset count rate threshold or NBR alarm

21
Q

What happens if more than 200 spectra are stored without overwrite enabled?

A

User is prompted to confirm overwrite

22
Q

What kind of batteries does the RadEye SPRD-GN use?

A

AAA Alkaline or rechargeable

23
Q

What unit is not supported by the RadEye SPRD-GN for dose measurements

24
Q

How are menu options made invisible to simplify the user interface

A

Via the PC configuration software

25