An electric hot water tank with immersion elements is considered to be
100 % efficient
(all heat from element is transferred to the water)
An instantaneous hot water heater has a _____ that activates the burner when water is drawn.
Control valve
A baffle is often placed in the flue passage if a centre flue HWT to
Slow the exit of hit combustion gases
Which of the following is not found on a T&P relief valve information tag?
A. Size of valve
B. BTU rating of HWT
C. Pressure setting
D. Sensor length
B. BTU rating of HWT
Stall urinals are installed
During the rough-in stage
A single trap may serve a 3 compartment sink if it is
One size larger than the largest fixture outlet pipe
The copper water service pipe to a building should be
Type K or L soft copper tube
ABS or PVC horizontal piping must be supported at intervals not exceeding
4 feet (1.2 m)
A 1/8 th bend refers to a cast iron fitting used to change direction by
45 degrees
When installing a bypass for a pressure reducing valve, it is best to use a _____ valve
Globe valve
BCuP brazing alloy may be used to join copper tube to copper fittings
A. Only if flux is also used
B. Only if the copper tube is hard drawn
C. Without using flux
D. Without exceeding 800 ‘F
C. Without using flux
The most common cause of the collapse of a hot water tank is
Vacuum
What would be the most correct definition of total force?
A. Total weight of water divided by surface area
B. Weight of water times surface area
C. Weight of water per square inch
D. Pressure divided by surface area
B. Weight of water times surface area
The maximum length of a disposal field lateral, according to the BC Health Act is
100 ft
A pressure tanks main purpose, when used in a rural water supply system, is to
Prevent cycling of the pump
The actual lift of a pump is less than the theoretical lift. This is caused by:
The loss of efficiency due to friction.
The inability of the pump to create a perfect vacuum.
The changes in atmospheric pressure above sea level.
The minimum diameter of a water service is:
3/4”
Threaded drainage fittings installed in a vertical stack are tapped to provide a pitch of ___
1/4” per foot
A combined sewer carries
Sanitary and storm sewage
The maximum fall on a trap arm from the weir to the vent is
1 pipe diameter
The vertical distance between the trap weir and the trap dip is the
Trap seal depth
The developed length of a branch vent shall be
From its upper end to the farthest downstream fixture that it serves
An ordinary displacement type water meter registers
The total flow though the meter
Which of the following meters is two meters in one?
A. Turbine
B. Displacement
C. Oscillating piston
D. Compound
D. Compound
Low flow rate: displacement
High flow rate: turbine