What is the C-1 Conditional?
Intermediate Range Rod Stop
- Stops AUTO and MANUAL Rod Withdraw
- 1/2 - IRNI > 18% (16%)
- Manually blocked above P10 (≥ 10% PR)
- Unblocked below P10
What is the C-2 Conditional?
Power Range Rod Stop
- Stops AUTO and MANUAL Rod Withdraw
- 1/4 PR > 103%
- Blocked when ROD STOP BYPASS selected to alarming channel
What is the C-3 Conditional?
OTΔT Rod Stop
- 2/4 PRNI 3% < trip setpoint
- Stops AUTO and MANUAL rod withdraw
- No Block!
What is the C-4 Conditional?
OPΔT Rod Stop
- 2/4 PRNI 3% < trip setpoint
- Stops AUTO and MANUAL rod withdraw
- No Block!
What is the C-5 Conditional?
Turbine Power Interlock
- MPC-253 < 15%
- Stops AUTO ONLY rod withdraw
- No Block!
What is the C-11 Conditional?
Control Bankd D Rod Stop
- Ctrl Bank D at 229 steps
- Stops AUTO ONLY rod withdraw
- No Block!
What are the Rod Ctrl Inputs?
- Auctioneered High Tave
- Auctioneered High PR NI
- MPC-253, Turbine 1st Stage Impulse #
Where are the MG Sets powered from?
11/21A and 11/21D busses
Given the following conditions:
* Unit 1 is at 100% power
* A loss of power to CRP-3 occurs
What is the effect on the Rod Position Indication (RPI) system and the procedural action necessary, if any?
RPI indications are lost. Dispatch an operator to manually align backup power supply (via ELSC) to energize the RPI Cabinets. Operation is allowed since RPI has been restored.
What does the Variable Gain Unit do?
Increases the output at low power because reactivity change at lower power has a smaller effect on power than at high power
At what speed do the shutdown banks move?
62 SPM
At what speed do the rod ctrl banks move in auto?
8-72 SPM
- Error of 1.5-3 degrees = 8 steps per minute
- Error of 3-5 degrees = 32 steps per Degree + 8
1.5-3 degrees - 8 steps
3.5 degrees - 24 steps
4 degrees - 40 steps
4.5 degrees - 56 steps
5 degrees - 72 steps
At what speed do the rod ctrl banks move in manual?
48 SPM
What is Differential Rod Worth?
The change in reactivity resulting from a unit change of rod position. (pcm/step)
What is Integral Rod Worth?
Reactivity inserted by moving a control rod from a reference position to any other rod height
When does the Rod dropped/Rod Bottom alarm clear for Control Bank A?
When all shutdown Banks are withdrawn AND Control Bank A gets to 20 Steps
If MPC-253 fails low, what happens with rods in automatic? Why?
Rods will step in due to PR rate change and temp error
When does the Rod Dropped alarm enabled for Control Banks B-C?
When demand is > 35 steps for that group
When does the Rod Dropped alarm annunciate for Control Banks B -C?
When IRPI is < 20 steps with a demand > 35 steps, AFTER the alarm has been enabled.
When do Rod Bottom lights clear for the control banks?
When the rods are withdrawn > 20 steps
If MPC-253 fails high, what happens with rods in automatic? Why?
Rods step OUT due to power rate of change and temperature error
If Tavg fails high, what happens with rods in automatic? Why?
Rods step in due to the temperature error
If Tavg fails low, what happens with rods in automatic? Why?
NOTHING! Rod control uses auctioneered high Tavg
If a Power Range NI fails low, what happens with rods in automatic? Why?
Nothing! Rod control uses auctioneered high